Range
Questions? Call GE Appliances at 1.800.GE.CARES (1.800.432.2737) or visit
GEAppliances.com. In Canada, call 1.800.561.3344 or visit GEAppliances.ca.
IN THE COMMONWEALTH
OF MASSACHUSETTS
■ This product must be installed by a licensed
plumber or gas fitter.
WARNING
FIRE OR EXPLOSION
HAZARD
If the information in this manual is not followed
exactly, a fire or explosion may result causing
property damage, personal injury or death.
Installation must be performed by a qualified
installer.
Read these instructions completely and carefully.
Installation of this range must conform with
local codes, or in the absence of local codes,
with the National Fuel Gas Code, ANSI Z223.1/
NFPA.54, latest edition. In Canada, installation
must conform with the current Natural Gas
Installation Code, CAN/CGA-B149.1 or the
current Propane Installation Code, CAN/CGA-
B149.2, and with local codes where applicable.
This range has been design-certified by
CSA International according to ANSI Z21.1,
■ When using ball type gas shut-off valves,
they shall be the T-handle type.
■ A flexible gas connector, when used, must
not exceed 5 feet.
latest edition and Canadian Gas Association
according to CAN/CGA-1.1 latest edition.
When installing a gas appliance the use of
old flexible connectors can cause gas leaks
and personal injury. Always use a NEW
flexible connector.
Leak testing of the appliance shall be conducted
according to the manufacturer instructions.
The range must be electrically grounded in
accordance with local codes or, in the absence
of local codes, in accordance with the National
Electrical Code (ANSI/NFPA 70, latest edition).
In Canada, electrical grounding must be
in accordance with the current CSA C22.1
Canadian Electrical Code Part 1 and/or local
codes. See Electrical Connections in this section.
Do not install this product with an air curtain
hood or other range hood that operates by
blowing air down on the cooktop. This airflow
may interfere with operation of the gas burners
resulting in fire or explosion hazard.
FOR YOUR SAFETY:
WARNING
Tip-Over Hazard
• A child or adult can tip the range and be killed.
• Install the anti-tip bracket to the wall or floor.
• Engage the range to the anti-tip bracket by sliding the
range back such that the foot is engaged.
• Re-engage the anti-tip bracket if the range is moved.
• Failure to do so can result in death or serious burns
to children or adults.
If you did not receive an anti-tip bracket with your
purchase, call 1.800.626.8774 to receive one at
no cost. (In Canada, call 1.800.561.3344.) For
installation instructions of the bracket,
visit: GEAppliances.com.
(In Canada, GEAppliances.ca.)
Anti-Tip Bracket
Kit Included
WARNING
Before beginning
the installation, switch power off at
service panel and lock the service
disconnecting means to prevent power
from being switched on accidentally.
When the service disconnecting
means cannot be locked, securely
fasten a prominent warning device,
such as a tag, to the service panel.

Advertisement

Table of Contents
loading

Summary of Contents for GE P2S930

  • Page 1 Tip-Over Hazard • A child or adult can tip the range and be killed. Questions? Call GE Appliances at 1.800.GE.CARES (1.800.432.2737) or visit • Install the anti-tip bracket to the wall or floor. • Engage the range to the anti-tip bracket by sliding the GEAppliances.com.
  • Page 2: Tools You Will Need

    TOOLS YOU WILL NEED MATERIALS YOU MAY NEED BEFORE YOU BEGIN Mobile Home - Additional Installation Requirements ■ Gas line shut-off valve IMPORTANT — Save these The installation of this range must conform ■ Pipe joint sealant or UL-approved pipe thread instructions for local inspector’s use.
  • Page 3: Dimensions And Clearances

    DIMENSIONS AND DIMENSIONS AND CLEARANCES (CONT.) flame-retardant millboard covered with no less than No. 28 MSG sheet metal (.015” [.38 mm] CLEARANCES GAS PIPE AND ELECTRICAL OUTLET LOCATIONS thick), .015” (.38 mm) thick stainless steel, .025” (0.64 mm) aluminum or .020” (0.5 mm) copper. Provide adequate clearances between the range and adjacent combustible surfaces.
  • Page 4 INSTALLATION AT HIGH ALTITUDE Over 6000ft, product configured for natural gas or propane requires installation of kit (WB28X29254 for natural gas and WB28X29255 for propane gas). Follow the instructions included with the kit. INSTALLATION INSTRUCTION 31-2000834 Rev. 0 09-20 GEA P2S930...
  • Page 5: Electrical Requirements

    ELECTRICAL REQUIREMENTS POWER CORD AND CONDUIT INSTALLATION WARNING Remove wire cover (on the back of range) by removing screws using a 1/4” nut driver. You This appliance must be properly grounded. can access the terminal block by either removing a terminal block cover (on some models) or the wire cover.
  • Page 6 3-WIRE INSTALLATION (GROUND IS THROUGH THE 4-WIRE INSTALLATION (SEPARATE GROUND WIRE) NEUTRAL WIRE) WARNING Before–Power Cord and Conduit The neutral wire of Power Cord WARNING the supply circuit must be connected to the Shock Hazard neutral terminal located in the lower center Ground strap The neutral wire and ground strap must be Terminal block...
  • Page 7: Gas Supply

    To prevent gas leaks, put pipe joint compound GAS SUPPLY SURFACE BURNERS on, or wrap pipe thread tape with Teflon* around, all male (external) pipe threads. WARNING A. Install a manual shut-off valve in the gas line WARNING Fire Hazard: Do not use in an easily accessed location outside of the Fire or Explosion Hazard: range.
  • Page 8: Level The Range

    H. Look under the unit and verify that the rear leg is fully engaged with the anti-tip device. If not, remove the unit and adjust the height of the rear leg so that it is properly engaged. Spirit level INSTALLATION INSTRUCTION 31-2000834 Rev. 0 09-20 GEA P2S930...
  • Page 9: Para Su Seguridad

    ADVERTENCIA Riesgo de Caída • Un niño o adulto pueden volcar la cocina y morir. ¿Preguntas? Llame a GE Appliances al 800.GE.CARES (800.432.2737) o visita • Instale el soporte anti-volcaduras sobre la pared o el piso. Kit de soporte • Asegúrese la estufa al soporte anti-volcaduras deslizando GEAppliances.com.
  • Page 10 HERRAMIENTAS NECESARIAS MATERIALES NECESARIOS ANTES DE COMENZAR Casa Rodante – Requisitos de Información Adicional ■ Válvula de cierre para tubería de gas IMPORTANTE — Conserve estas instrucciones Esta cocina se deberá instalar conforme con el ■ Sellador para junta de tubería o UL – cinta para para uso del inspector de electricidad local.
  • Page 11: Dimensiones Y Espacios

    DIMENSIONES Y ESPACIOS metálica de 28 MSG (.015” (.38 mm) de grosor), DIMENSIONES Y ESPACIOS (CONT.) .015” (.38 mm) de grosor de acero inoxidable, .025” Deje el espacio adecuado entre la cocina y las UBICACIONES DE LA TUBERÍA DE GAS Y DEL TOMACORRIENTE ELÉCTRICO (0.64 mm) de aluminio o .020”...
  • Page 12 A más de 6000 pies, el producto configurado para gas natural o propano requiere la instalación del kit (WB28X29254 para gas natural y WB28X29255 para gas propano). Siga las instrucciones incluidas con el kit. INSTRUCCIONES DE INSTALACIÓN 31-2000834 Rev. 0 09-20 GEA P2S930...
  • Page 13: Requerimientos Eléctricos

    REQUERIMIENTOS ELÉCTRICOS INSTALACIÓN DE CABLE DE ENERGÍA Y DE PASACABLES ADVERTENCIA Esta unidad debe contar con una adecuada conexión a tierra. Quite la tapa del cable (en la parte trasera de la cocina) quitando tornillos mediante una llave de tuercas de 1/4”.
  • Page 14 INSTALACIÓN DE TRES (3) ALAMBRES (LA CONEXIÓN A INSTALACIÓN DE 4 ALAMBRES (CABLE DE CONEXIÓN A TIERRA SE REALIZA A TRAVÉS DEL CABLE NEUTRO) TIERRA SEPARADO) Antes–Cable de energía ADVERTENCIA ADVERTENCIA y conducto portacables Cable de energía El cable neutral del Riesgo de Descarga Cinta de circuito de suministro debe estar conectado a la...
  • Page 15 Para evitar pérdidas de gas, coloque el compuesto SUMINISTRO DE GAS Tapa SUPERFICIALES de la junta de gas, o envuelva la cinta para roscas de Tapa tuberías con Teflón* alrededor de todas las roscas de UEMADORES ADVERTENCIA tubería macho (externas). Tapa Riesgo de incendio: A.
  • Page 16 De no ser así, retire la unidad y ajuste la altura de la pata trasera de modo que quede correctamente adherida. Nivel de Agua INSTRUCCIONES DE INSTALACIÓN 31-2000834 Rev. 0 09-20 GEA P2S930...