  • Page 1 DEALER: This manual must be given to the user of the patient lift. USER: Before using this patient lift, read this manual and save for future reference. SERVICE AGENT: Only Drive DeVilbiss Healthcare authorized service agents are permitted to install, service or repair DRIVE product.
  • Page 2: Table Of Contents

    Owner's Manual REV2.7.14.20 TABLE OF CONTENTS STANDARD SYMBOLS USED IN THIS MANUAL ................3 INTENDED USE ........................... 4 CONTRA-INDICATIONS ......................4 GENERAL SAFETY ........................5 ELECTROMAGNETIC EMISSION AND IMMUNITY ..............8 FEATURES AND BENEFITS ......................11 TECHNICAL SPECIFICATIONS ....................12 COMPLIANCE INFORMATION ....................13 UNPACKING INSTRUCTIONS ....................13 ASSEMBLY ..........................14 OPERATION ..........................18...
  • Page 3 Owner's Manual REV2.7.14.20 The Drive DeVilbiss Healthcare’s Sit to Stand Lifts Product# Product Name Power/Manual Base Weight Capacity STSP450 Sit to Stand Lift Power 450lbs STSM450 Sit to Stand Lift Manual 450lbs Handgrip Sling Attachment Hook Push Handle Hand Control...
  • Page 4: Standard Symbols Used In This Manual

    Owner's Manual REV2.7.14.20 STANDARD SYMBOLS USED IN THIS MANUAL This manual includes important information about the safety of personnel and equipment. As you read through this manual be aware of the symbols and their meanings. DANGER Information that appears under the DANGER symbol concerns the protection of personnel from direct and pending hazards that, if not avoided, will result in immediate, serious personal injury or death in addition to damage of the equipment.
  • Page 5: Intended Use

    The intended use of this lifting device is for the safe lifting and transfer of an individual from one resting surface to another (such as a bed to a wheelchair). Drive DeVilbiss Healthcare recommends that the transfer of a patient is fully risk assessed and conducted safely over a short distance only.
  • Page 6: General Safety

    • Drive DeVilbiss Healthcare patient lifts may be safely operated by a single appropriately trained and experienced caregiver, in accordance with ISO 10535:2006. However, there are circumstances (including but not limited to the patient’s medical, psychological or behavioral condition, as well as the caregiver’s...
  • Page 7 DRIVE’s patient lifts. Slings and accessories designed by other manufacturers are not to be utilized as a component of DRIVE’s lift system. Use of these products is prohibited and will void DRIVE’s patient lift warranty. Use only DRIVE’s slings and patient lift accessories to maintain patient safety and product utility.
  • Page 8 Owner's Manual REV2.7.14.20 WARNING • DO NOT attempt to negotiate a loaded lift on a slope, which exceeds 1:12 (aprox. 5 degrees) • The battery must be connected to an appropriate power source when loss of power source would result in an unacceptable risk •...
  • Page 9: Electromagnetic Emission And Immunity

    Drive DeVilbiss Healthcare does NOT recommend locking the rear swivel casters of the lift when lifting and transferring an individual. Doing so could cause the lift to tip and endanger the patient and assistants. Drive DeVilbiss Healthcare does recommend that the rear swivel casters be left unlocked...
  • Page 10 Owner's Manual REV2.7.14.20 DECLARATION - ELECTROMAGNETIC EMISSIONS Guidance and manufacturer's declaration - Electromagnetic emissions The Prime Care™STSP450, STSM450 is intended for use in the electromagnetic environment specified below. The customer or the user of the Prime Care™ STSP450, STSM450 should ensure that it is used in such an environment.
  • Page 11 Owner's Manual REV2.7.14.20 Guidance and manufacturer's declaration: Electromagnetic Immunity The Prime Care™ STSP450, STSM450 is intended for use in the electromagnetic environment specified below. The customer or the user of the Prime Care™ STSP450, STSM450 should ensure that it is used in such an environment. Immunity test IEC 60601 test Compliance...
  • Page 12: Features And Benefits

    ➢ Lift Serial Numbers When ordering parts or when contacting Drive DeVilbiss Healthcare Customer Service Department, please include lift's model and serial numbers, found on the identification labels as below. The identification labels are located on the legs of lift...
  • Page 13: Technical Specifications

    Owner's Manual REV2.7.14.20 TECHNICAL SPECIFICATIONS Hoisting Range/Reach Base Base Height/Clearance Hoisting Range/Reach (Unit: mm) Base (Unit: mm) 1. Max overall height....1494 1. Max external length.....1069 2. Height at Max reach....956 2. Max internal length.......780 3. Min overall height.....780 3. Internal width when closed..534 4.
  • Page 14: Compliance Information

    COMPLIANCE INFORMATION Matching the correct lift components to meet regulatory specifications can be complicated. Drive DeVilbiss Healthcare offers a wide variety of compliance options and we can assist your facility in selecting components or accessories that are recommended for the specific lift model.
  • Page 15: Assembly

    Owner's Manual REV2.7.14.20 ASSEMBLY KNOWLEDGE/SKILLS REQUIRED • Ability to read and understand • Ability to manipulate required owner’s manual tools • Basic mechanical aptitude TOOLS REQUIRED • Philips Screwdriver • Allen Wrench #13,14,16,18,20 • Adjustable Wrench WARNING • Installation MUST be performed ONLY by qualified personnel. •...
  • Page 16 Owner's Manual REV2.7.14.20 4. Secure the mast to the base with four hex screws(5/16"-18*5/8")and one hex set screw(1/4"-20*1/2"). 5. If you are assembling the manual base, connect the manual leg adjustment shifter handle to the base with one hex set screw (1/4"-20*1/2") 6.
  • Page 17 Owner's Manual REV2.7.14.20 8. Secure the lifting actuator to the boom with the hex bolt (3/8"-16*2 1/4"). 9. Install the control box onto the mounting bracket on the mast, and tighten the control box with two mounting screws (M4). 10. Fit battery to control box and make sure the latch holding the battery in place is fully engaged “Click”...
  • Page 18 Owner's Manual REV2.7.14.20 12. Attach the footplate to the base 13. Attach the kneepad to the kneepad receiver Note The lift should not be disassembled unless for service, repair or transport if : necessary. If disassembly is required, simply follow the assembly instructions in reverse sequence.
  • Page 19: Operation

    Owner's Manual REV2.7.14.20 OPERATION WARNING Always check the following before operation: • The mast is fully locked into position. • Confirm the boom rises and lowers (This is done via the hand control). • The legs of the lift open and close satisfactorily (This is done via the hand control or shifter handle).
  • Page 20 Owner's Manual REV2.7.14.20 Emergency Stop The red Emergency Stop Button is located on the top of the control box and is activated by pressing in. This will cut all power to the lift and only be reset by twisting the button counter clockwise and releasing.
  • Page 21 Owner's Manual REV2.7.14.20 SMART/SAFETY CONTROL MODULE Redundant Control The Drive DeVilbiss Smart/Safety control module has two operation buttons and an LCD display (STSP450 only) on the top of control box (TC12) , redundant controls for operation if the hand control becomes inoperable, battery and an emergency stop button.
  • Page 22 Owner's Manual REV2.7.14.20 The Smart/Safety Control Module (STSP450 Only) The Drive DeVilbiss Smart/Safety control module stores useful servicing information about the lift that can be recalled when required. This servicing information includes: • Number of patient lift cycles • Total work done by actuator •...
  • Page 23 Owner's Manual REV2.7.14.20 1. Getting Started (STSP450 Only) • Connect the Smart/Safety learning hand control (see Figure G) for the setting mode. • Press to start the learning mode. 2. Language Setting • We have six (6) standard options: English, Chinese, German, French, Japanese, and Spanish.
  • Page 24 Owner's Manual REV2.7.14.20 3. Maintenance Cycle Setting (STSP450 Only) • Press the buttons to select the maintenance cycle menu. • Press the buttons to navigate to the maintenance cycle menu or return to the main menu. • Make your maintenance interval selection based on a time period or fixed number of cycles.
  • Page 25 Owner's Manual REV2.7.14.20 4. System Reset (STSP450 Only) • Press the to navigate to the reset menu. • Press the buttons to select after maintenance or return to the main menu. • “After Maintenance” System Reset Note: The maintenance interval settings are regulated by the number of cycles or months.
  • Page 26 Owner's Manual REV2.7.14.20 5. Usage History (STSP450 Only) • Press the buttons to navigate to the Usage History menu. • Press the buttons to scroll through the Usage History information or return to the main menu. Note: The Usage History menu includes information regarding the total usage and the last five usages.
  • Page 27: Battery Information

    Owner's Manual REV2.7.14.20 BATTERY INFORMATION WARNING • The only compatible battery is the Timotion BAT battery. • Must follow the rated input voltage. • Charge with certified charger from original manufacturer. • Don’t expose the battery to water or heat source. •...
  • Page 28: Care And Maintenance

    CARE AND MAINTENANCE CONTACT DETAIL Maintenance and Service MUST be performed ONLY by qualified personnel Contact Drive DeVilbiss Healthcare if you need any help with installation, usage or maintenance of the product. Corporate Office: Drive DeVilbiss Healthcare, 99 Seaview Blvd., Port Washington, NY 11050.
  • Page 29 MAINTENANCE SCHEDULE WARNING • All Drive DeVilbiss products are designed for minimum maintenance, however some safety checks and procedures are required. A schedule of DAILY tasks is detailed below. Daily checks and a yearly service, inspection and test will ensure a lift is kept in optimum safe working condition. A list of spare parts is available upon request.
  • Page 30: Servicing

    Owner's Manual REV2.7.14.20 Item Pre- Daily Minor Service Major Service Delivery (After every 3 (After every Months of 6 Months of Service) Service) SLINGS AND HARDWARE • CHECK ALL SLING ATTACHMENTS each time it is used to √ √ √ √...
  • Page 31 Owner's Manual REV2.7.14.20 ROUTING LAYOUT WARNING When routing cables in the medical lift, precautions shall be taken to avoid squeezing between parts of the lift. REPLACING CONTROL /BATTERY PACK 1. Install the bracket on 2. Install the control box 3. Make sure all fasteners the Lift Mast on the bracket are tightened properly...
  • Page 32: Troubleshooting Guide

    Owner's Manual REV2.7.14.20 TROUBLESHOOTING GUIDE WARNING Before doing any repairs or maintenance to the lift frame, read all instructions, cautions, and warnings. Repairs should be done by a skilled technician. Normal Symptom Possible Cause Solutions Patient Lift feels • Mast/Base joint loose. •...
  • Page 33: Warranty

    Owner's Manual REV2.7.14.20 WARRANTY PrimeCare STSP450,STSM450 Sit to stand Lifts are guaranteed for a 5 year period from the date of production. This guarantee is against defects in materials and craftsmanship, under normal use and service. This 5-year warranty includes electrical and mechanical parts and components. Lift mounted accessories are covered for 1 year.
  • Page 34: End Of Life Disposal

    This warranty is extended to the original purchaser of the equipment. SALES AND SERVICE Contact Drive DeVilbiss Healthcare if you need any help with installation, usage or maintenance of the product. Corporate Office: Drive DeVilbiss Healthcare, 99 Seaview Blvd., Port Washington, NY...
  • Page 35 Owner's Manual REV2.7.14.20 Drive DeVilbiss Healthcare, 99 Seaview Blvd., Port Washington, NY 11050 Ph: 1-877-224-0946 Fax: 516-988-4601 www.drivemedical.com REV2.7.14.20 The information in this document is subject to change without notice Page34...