9.39 SYSTEM MANAGER - CONNECTION TO ZONE REMOTE PANELS.

T
x
R /
x
G
N
D
J5
input voltage:
24Vac (+10%-15%); 50/60Hz
48Vdc (36Vmin...71Vmax)
max power:8VA/6W
J1
Key:
A3 - System manager
Zone remote panel: control panel (by
default with Audax Top ErP)

9.40 SYSTEM MANAGER - CONNECTION TO THERMOFLUE.

J5
J6
J9
J4
1 J
24Vac
TERMOCAMINO
FIREPLACE
T
x
R /
x
G
N
X
J6
J7
J8 ISOLATED
J2
Key:
A15-4: - Zone expansion kit with address 4
J7
J8
THERMOFLUE: -On/Off contact from thermoflue.
E/I: - Manual switching to cooling switch
J10
Note: - Configure the expansion address as indicated.
A15-4
Serial
Address
1 2 4
8
2 J
J3
PWM 0/10V
J9
J10
A13
J3
- Thermoflue: input contact to disable the generators when
a thermoflue operates. If the contact closes Audax, boiler/
resistances remain in stand-by.
The manual switching to cooling switch is a normally closed
contact which, when I set the system to cooling, must be
open to avoid inhibiting the activation of the HP in cooling
and DHW.
Indirizzi
Addresses
Serial
Expanding
Espansione
Address
1
2 4 8
Address
Indirizzo 4
1
2
3
4
ON
Alimentazione
Power Supply
24Vac 50Hz
79
Fig. 9-39
Remote zone panel
Pannello remoto di zona
Fig. 9-40