Immergas System Manager Kit Instructions And Warnings page 41

Hide thumbs Also See for System Manager Kit:
Table of Contents

Advertisement

parameter
P35
System decoupling
P35
System probe
P35
Photovoltaic
P41
Activation time
P41
Increase time
P42
Max Heat correction
P42
Max Cool correction
P43
Activation time
P43
Increase time
P44
Max Heat correction
P44
Max Cool correction
"Assistance \ Thermoregulation" menu.
parameter
T01
Enable use of external probe
T02
External probe
T02
Set zone 1 minimum flow
T02
Set zone 1 maximum flow
T03
External probe
T03
Set zone 2 minimum flow
T03
Set zone 2 maximum flow
T04
External probe
T04
Set zone 3 minimum flow
T04
Set zone 3 maximum flow
T05
External minimum temperature
T05
External maximum temperature
T06
Set zone 1 minimum flow
T06
Set zone 1 maximum flow
T07
Set zone 2 minimum flow
T07
Set zone 2 maximum flow
T08
Set zone 3 minimum flow
T08
Set zone 3 maximum flow
T09
External minimum temperature
T09
External maximum temperature
T10
External probe
T10
Set zone HT minimum flow
T10
Set zone HT maximum flow
T10
External minimum temperature
T10
External maximum temperature
"Assistance \ DHW" menu.
Description
Description
Range
adjustment
Yes/No
Yes/No
Yes/No
1-120
1-20
0-10
0-10
1-120
1-20
0-10
0-10
Range
adjustment
Not used, From heat
pump, From boiler
No/Yes
25 - 50
30 - 85
No/Yes
25 - 50
30 - 85
No/Yes
25 - 50
30 - 85
-20 - 0
+5 - +25
7-20
10-25
7-20
10 - 25
7 - 20
10 - 25
20-35
25-40
No/Yes
25 - 50
30 - 85
-20 - 0
5 - 25
41
Value
Value
default
range
No
No
No
10
3
0
0
20
5
2
0
Value
Value
default
customis.
From heat
pump
No
25
45
No
25
45
No
25
45
-5
25
18
20
18
20
18
20
25
35
No
25
45
-5
25