List Of Programmable Parameters - Immergas System Manager Kit Instructions And Warnings

Hide thumbs Also See for System Manager Kit:
Table of Contents

Advertisement

6
LIST OF PROGRAMMABLE PA-
RAMETERS
"Main" menu.
parameter
M01
Functioning modes
M02
DHW time program0.s
M02
Set DHW manual
M03
Set DHW comfort
M03
Set DHW ECO
M04
Set DHW boiler (separate circuit)
M05
Set ZN1 Room temp.
M05
Set ZN1 Flow Temp.
M05
ZN1 Flow Offset
M06
Set ZN2 Room temp.
M06
Set ZN2 Flow Temp.
M06
ZN2 Flow Offset
M07
Set ZN3 Room temp.
M07
Set ZN3 Flow Temp.
M07
ZN3 Flow Offset
M08
Set SHT Room temp.
M08
Set ZHT Flow Temp.
M08
ZHT Flow Offset
"Set room" menu.
parameter
S01
Set comfort ZN1 Air Conditioning
S01
Set reduced ZN1 Air Conditioning
S01
Set humidity ZN1 Air Conditioning
S02
Set comfort ZN2 Air Conditioning
S02
Set reduced ZN2 Air Conditioning
S02
Set humidity ZN2 Air Conditioning
S03
Set comfort ZN3 Air Conditioning
S03
Set reduced ZN3 Air Conditioning
S03
Set humidity ZN3 Air Conditioning
S04
Set comfort ZN1 Winter
S04
Set reduced ZN1 Winter
S05
Set comfort ZN2 Winter
S05
Set reduced ZN2 Winter
S06
Set comfort ZN3 Winter
S06
Set reduced ZN3 Winter
S07
Set comfort ZHT Winter
S07
Set reduced ZHT Winter
Description
Description
Range
adjustment
Stand-by, Summer, Air
conditioning, Winter
No / Yes
10 - 60
10- 50 (60 with boiler)
10- 50 (60 with boiler)
10-60
5,0 - 35,0 °C
5 - 85 °C °C
-15 - +15 °C
5,0 - 35,0 °C
5 - 85 °C °C
-15 - +15 °C
5,0 - 35,0 °C
5 - 85 °C °C
-15 - +15 °C
5,0 - 35,0 °C
5 - 85 °C °C
-15 - +15 °C
Range
adjustment
5 - 35
5 - 35
30% - 70%
5 - 35
5 - 35
30% - 70%
5 - 35
5 - 35
30% - 70%
5 - 35
5 - 35
5 - 35
5 - 35
5 - 35
5 - 35
5 - 35
5 - 35
34
Value
Value
default
customis.
Stand-by
No
10
20
10
20
20
25
0
20
25
0
20
25
0
20
25
0
Value
Value
default
customis.
25
28
50
25
28
50
25
28
50
20
16
20
16
20
16
20
16