Diagnostics And Errors; Diagnostics; Reset Errors - Immergas System Manager Kit Instructions And Warnings

Hide thumbs Also See for System Manager Kit:
Table of Contents

Advertisement

4

DIAGNOSTICS

AND ERRORS
4.1
DIAGNOSTICS.
The "System Manager Kit" control continually controls
the functioning status of the whole system and signals
any anomalies, stating the corresponding error code on
the display.
In the case of a fault that cannot be reset, contact a quali-
fied technician (e.g. the Immergas After-Sales Technical
Assistance Service).
The alarm code is displayed in the event of an error (e.g.
A0036, Fig. 4-1), with the symbol
above the relevant button.
08:50
VE
Sitting room
T:
00.0 °C
U:
00.0 %
Fig. 4-1
Press the button
to display the "Alarms log"; this
section displays occurred alarms, not yet reset, from the
most recent to the oldest.
Press arrows
to scroll and display all extant
alarms.
A l a r m s
l o g
N° 04
09:50
Alarm off-line
Audax
Fig. 4-2
The following faults are managed by the "System Man-
ager Kit":
- Storage tank probes fault (upper, lower and for central
heating)
- Solar collector probe anomalies
- Flow zone probe faults
- Return probe fault (solar)
- Heat pump anomalies
- Boiler anomaly
- Disabled solar operation
- Dehumidifier fault
- Ambient and humidity probe fault (for all zones)
and icon
10/06/11
M01
A0036
H 0 1
10/06/11
A0036
If no alarm has been triggered, it is still possible to view
the "Alarms log" by proceeding as follows:
- press the button
- scroll with buttons
select "05. ALARMS RECORDS".
N a v i g a t i o n
04.
INFO
05.
ALARMS HISTORY
06.
SERVICE
Fig. 4-3
- Press the
button to enter the menu.
As well as the error codes referring to the functioning
state of the system, the"System Manager Kit" also checks
its own functioning state, indicating any malfunctions.
4.2

RESET ERRORS

Press the button
the navigation menu (Fig. 4-3).
Press and hold the RES button (Fig. 4-2) to display the
screen where it will be possible to reset the alarms and
heat pump log (Fig. 4-4).
A l a r m s
l o g
Reset log?
Reset alarm of
Audax and boiler:
Fig. 4-4
Press button
for the option "Reset log" to start
blinking.
Press arrows
any reset. At the end, press button
for the option "Reset Audax and boiler alarms" to start
blinking. Proceed in the same manner to reset any pump
and boiler alarms.
At the end press button
main screen.
20
;
the navigation menu and
m e n u
to display the "Alarms log" or via
No
No
to confirm (YES) or cancel (NO)
to confirm and
twice to go back to the
H 0 2