  • Page 1 WaveRunner 8000-R Oscilloscopes Getting Started Guide...
  • Page 2 Teledyne LeCroy documentation for internal educational purposes. Teledyne LeCroy is a trademark of Teledyne LeCroy, Inc. Other product or brand names are trademarks or requested trademarks of their respective holders. Information in this publication supersedes all earlier versions. Specifications are subject to change without notice.
  • Page 3: Table Of Contents

    Welcome Contents Thank you for buying a Teledyne LeCroy product. We’re certain you’ll be Introducing WaveRunner 8000-R pleased with the detailed features unique to our instruments. Key Specifications This guide is intended to help you install a WaveRunner 8000-R Safety oscilloscope into your test environment and prepare it for remote control.
  • Page 4: Introducing Waverunner 8000-R

    Unlike most digitizing systems, the WaveRunner 8000-R provides Max. Memory 32 Mpts 128 Mpts 128 Mpts the powerful, deep toolbox that is expected in a Teledyne LeCroy Max. Sample Rate 20 GS/s 40 GS/s 40 GS/s oscilloscope. The full range of the WaveRunner 8000’s analysis capability...
  • Page 5 Do not operate with suspected failures. Check body and cables regularly. Measuring terminals are not intended to be connected directly to supply mains. If any part is damaged, cease operation immediately and sequester the instrument from inadvertent use. WaveRunner 8000-R Getting Started Guidel...
  • Page 6: Front Of Oscilloscope

    OVERVIEW Front of Oscilloscope A. Power On/Standby Switch F. Auxilliary (AUX) Output B. Remote Status Indicator G. Calibration Output Terminal C. Analog Inputs C1-C4 H. LBUS Port (reserved) D. External Trigger Input I. Ground Terminal E. USB 2.0 Port 930948-00 Rev A...
  • Page 7: Back Of Oscilloscope

    B. USBTMC Port F. USB 3.1 Gen1 Ports (2) C. External Reference Clock G. DisplayPort Video Output Input (REF In) and Output (REF Out) H. VGA Video Output D. Removable Hard Drive I. Ethernet Ports (2) WaveRunner 8000-R Getting Started Guidel...
  • Page 8: Powering On/Off

    LeCroy VICP Passport for NI-VISA. Presets If the controller runs Windows, we recommend an installation of the free The WaveRunner 8000-R reverts to these factory defaults whenever Teledyne LeCroy WaveStudio software. WaveStudio will help you establish restarted after powering down: and test the remote connection.
  • Page 9 PC and the oscilloscope to TCP/IP communications on port 111. 6. In the top pane of the Terminal, enter the query: *IDN? 2. Power on the WaveRunner 8000-R and connect to a network access point using a standard Ethernet cable. It is helpful if the network is If the WaveRunner 8000-R responds with its identifying information, served by a DHCP server, as this will allow you to test addressing.
  • Page 10: Remote Configuration

    This name is also available over LAN: from MAUI by going to Support > About. If the WaveRunner 8000-R is on • TCPIP (VICP) supports MATLAB, VBA, VBS, C/C++ and JavaScript. To...
  • Page 11 Record the GPIB address for use in VISA and ActiveDSO connect strings. Direct Connection The WaveRunner 8000-R can be controlled over a coaxial cable or a straight ENET cable capable of directional switching (as most modern cables are). In this case, choose Control From TCPIP (VICP) and follow all other requirements for that method.
  • Page 12: Rackmounting

    The mounting "ears" should be flush with the front of the unit. The WaveRunner 8000-R rackmount kit is delivered with: 2. Using two of the M4x6 screws included with the rackmount kit, attach • Two (2) mounting brackets the left bracket to the oscilloscope body.
  • Page 13 BASICS WaveRunner 8000-R Getting Started Guidel...
  • Page 14: Cleaning

    MAINTENANCE Cleaning Firmware Updates Clean the outside of the WaveRunner 8000-R using a soft cloth moistened Free firmware updates are available periodically from the Teledyne with water or isopropyl alcohol solution. Do not use harsh or abrasive LeCroy website at teledynelecroy.com/support/softwaredownload under cleansers.
  • Page 15: Service

    SERVICE Service Service Plans If the WaveRunner 8000-R cannot be serviced on location, contact your Extended warranty, calibration, and upgrade plans are available for service center for a Return Material Authorization (RMA) code and purchase. Contact your Teledyne LeCroy sales representative or instructions where to ship the product.
  • Page 16: Certifications

    Certifications 2 Emissions which exceed the levels required by this standard may occur when the instrument is Teledyne LeCroy certifies compliance to the following standards as of connected to a test object. the time of publication. Please see the EC Declaration of Conformity 3 This product is intended for use in nonresidential areas only.
  • Page 17 – Part 2-030: Particular For more information about proper disposal and recycling of your requirements for testing and measuring circuits Teledyne LeCroy product, please visit teledynelecroy.com/recycle. The design of the instrument has been verified to conform to the RESTRICTION OF HAZARDOUS SUBSTANCES (RoHS)
  • Page 18: Warranty

    The product is warranted for normal use and operation, within specifications, for a period of three years from shipment. Teledyne LeCroy will either repair or, at our option, replace any product returned to one of our authorized service centers within this period.