Summary of Contents for Teledyne Lecroy PP006D

  • Page 1 Operator’s Manual PP006D Passive Probe...
  • Page 2 Customers are permitted to duplicate and distribute Teledyne LeCroy documentation for internal educational purposes. Teledyne LeCroy is a trademark of Teledyne LeCroy, Inc. Other product or brand names are trademarks or requested trademarks of their respective holders. Information in this publication supersedes all earlier versions. Specifications are subject to change without notice.
  • Page 3: Terms And Symbols

    DOUBLE INSULATION PROTECTIVE (EARTH) TERMINAL Introduction The Teledyne LeCroy PP006D is a passive probe with a wide range of probing accessories. It is designed to give high-impedance probing capability to a circuit when attached to a Teledyne LeCroy oscilloscope. To avoid electric shock, keep fingers behind the probe’s finger guard during use.
  • Page 4: Specifications

    PP006D Passive Probe Specifications System Input Probe Compensation Attenuation Impedance Length Range R (MΩ) C (pF) (MHz) (pF) 10 ±2% 12.5 ±10% 14 - 25 (-3 dB) Attenuation Ratio ..10:1 ± 2% (excepting characteristics of oscilloscope) Max. Input Voltage ..Circuits not directly connected to Mains: 350 Vrms, .........
  • Page 5 Operator’s Manual Input Impedance Profile...
  • Page 6: Voltage Vs. Frequency Derating Curve

    PP006D Passive Probe Voltage vs. Frequency Derating Curve Not directly connected to Mains CAT II General Safety Information Observe generally accepted safety procedures in addition to those listed here to avoid personal injury or damage to equipment. The overall safety of any system incorporating this accessory is the...
  • Page 7 Operator’s Manual Connect only to grounded instruments. Use only with compatible Teledyne LeCroy oscilloscopes that have their BNC input connected to an earth ground. Do not connect the probe reference lead to any point which is at a potential other than earth ground. Connect and disconnect properly.
  • Page 8: Ec Declaration Of Conformity

    PP006D Passive Probe EC Declaration of Conformity The probe conforms to the applicable European Union requirements per Low Voltage Directive (LVD) 2014/35/EU. Compliance was demonstrated to the following specification as listed in the Official Journal of the European Communities: IEC/EN 61010-031:2015 Safety requirements for electrical equipment for measurement, control and laboratory use –...
  • Page 9: Probe Compensation

    Operator’s Manual Probe Compensation Proper compensation of the probe is required to assure amplitude accuracy of the waveform being measured by matching the probe to the oscilloscope’s input capacitance. Compensation should be adjusted whenever the probe is connected to or transferred between oscilloscopes. Connect the sprung hook to the oscilloscope’s CAL OUT terminal and the ground lead to the GND terminal.
  • Page 10 • cause deterioration of the probe body, cables, and accessories. Service Refer all repairs to qualified service personnel. Contact Teledyne LeCroy at the following address to arrange to return the probe for service: Teledyne LeCroy, Inc. 700 Chestnut Ridge Road...
  • Page 11: Replaceable Parts

    Operator’s Manual Replaceable Parts Description Quantity Adjustment Tool Color Coding Rings (yellow, red, blue, green) 1 set of 4 Standard Ground Lead IC Test Tip Sprung Hook Ground Attachment All replacement parts are in Standard Accessory Replacement Kit PK118.
  • Page 12: Warranty

    Spare parts, replacement parts and repairs are warranted for 90 days. In exercising its warranty, Teledyne LeCroy, at its option, will either repair or replace any assembly returned within the warranty period to the Customer Service Department of an authorized service center.