PARAmETER
Description
10
D.h.w. thermostat hysteresis
11
D. h. w. post-circulation
12
Recirculating pump timer
13
Recirculating pump economy interval (pause)
14
Recirculating pump economy interval (period lenght)
Regulation
Setting range / Parameters
5 K
2 ... 20 K;
Value simmetric to d.h.w. set-point
1 min
0 ... 60 Min
AUTO
AUTO
- Active d.h.w. time-program
1
- P1, direct heating circuit
2
- P2, direct heating circuit
3
- P3, direct heating circuit
4
- P1, mixed heating circuit 1
5
- P2, mixed heating circuit 1
6
- P3, mixed heating circuit 1
7
- P1, mixed heating circuit 2
8
- P2, mixed heating circuit 2
9
- P3, mixed heating circuit 2
10
- P1, domestic hot water circuit
11
- P2, domestic hot water circuit
12
- P3, domestic hot water circuit
5 min
0 Min ... value of parameter 14;
interval in wich the pump doesn't work
20 min
1 .. 60 Min
(pause +
period)
Page 30