Setting The Heating Characteristics (Heating Curve) - Immergas VICTRIX PRO 35 1 I Instructions And Warning Book For The Users

Cascade and zone regulator zone manager
Hide thumbs Also See for VICTRIX PRO 35 1 I:
Table of Contents

Advertisement

Setting the heating characteristics (heating curve).

Direct heating
circuit
Select
circuit
heat. curve
Hc
confirm selection
Set
slope
heat. curve
Hc
store modification
heat. curve
Hc
next
Select
circuit
Mixed heating
circuit 1
heat. curve
Mc1
1.50
1.00
Setting range:
0,20...3,50
Factory preset:
Direct circuit (HC)
Mixed heating circuit 1 (MC 1)
1.50
Mixed heating circuit 2 (MC 2)
heat. curve
Mc 1
1.50
1.00
The adjustment is independent of the system and shows
the relation between outside temperature and max.
heating temperature.
Mixed heating
The slope sets the change of the max. heating tempera-
circuit 2
ture, if the outside temperature changes for 1 °C.
heat. curve
Mc2
1. 00
exit
= 1,50
= 1,00
= 1,00
Re-entry into the standard display is done pressing
heat. curve
the button
Mc 2
1. 00
exit
60 seconds.
This button regulates the heating characteristics
of each heating circuit in relation to outside
temperature
Diagram of heating curves
100
90
80
70
60
50
40
30
20
20 16 12 8 4
0 -4 -8 -12 -16 -20
Outside temperature (°C)
again or automatically after approx.
2.00
1.75
(Hc)
1.50
1.25
(MC1, MC2)
1.00
0.75
0.50
0.20
Page 9