1.10 GAS CONNECTION
Make the gas connection of the Mag-
is C omb o Plus V 2 or Vic t r ix Hy br id
Plus indoor units using the specific pipe
(Ref. h Fig. 17 and Fig. 23), tap and reducer
supplied and referring to the connection tem-
plate on the Solar Container or the Domus
Container and to the instruction booklets
of the relative indoor units.
1.11 BASIC MAGIS PRO HYDRAULIC
CONNECTION.
Make the hydraulic connection of the Basic
Magis Pro, using the optional kits available and
referring to the relative instruction sheet and to
the connection template on the Solar Container
and Domus Container.
Attention: before making the connections, care-
fully clean the heating system (pipes, radiators,
etc.) with special pickling or de-scaling products
to remove any deposits that could compromise
correct operation of the indoor unit and the
hydraulic unit.
N.B.: remove all the protection caps on the flow
and return pipes of the hydraulic unit, before
making the hydraulic connections.
The connections can be made directly using the
couplings on the hydraulic unit or by inserting
system cut-off cocks (optional). These cocks are
particularly useful for maintenance as they allow
you to drain the unit separately without having
to empty the entire system.
Attention: to preserve appliance duration and
efficiency features, we recommend installing a
suitable water treatment device if the water has
features that can lead to scale deposits.
29
1.12 SAFETY VALVE DRAIN.
8 bar domestic hot water safety valve.
Screw the fitting (d9) onto the safety valve. Screw
the funnel (d10) onto the fitting (d9) and convey
the outlet to the drains.
3 bar system safety valve.
Connect the silicone pipe (d11) to the drain of
the safety valve in the indoor unit (see the relative
instruction booklet) and after cutting it to size,
insert it into the funnel (d10) as shown in Fig. 30.
Attention: the drain of the safety valve in the
Victrix Hybrid Plus has been conveyed to the
condensate drain trap outlet.
1.13 CONDENSATE DRAIN.
To drain the condensation produced by the
Indoor Units, dismantle the relevant pipe on
the indoor unit itself and replace it with the one
supplied with the product (longer) and convey
the outlet towards the drains, via suitable pipes
that can withstand acid condensation, with an
internal Ø of at least 13 mm. The system connect-
ing the appliance to the drainage system must be
carried out in such a way as to prevent freezing of
the liquid contained in it. Before product start-
up, ensure that the condensate can be correctly
removed. Also, comply with standards in force
(UNI 11071) with national and local regulations
on discharging waste waters.
d9
d10
1.14 ELECTRICAL CONNECTION.
Refer to the relative instruction booklet for
the electrical connections of the indoor and
outdoor units.
• Connecting the DHW probe.
Install the DHW probe on the storage tank unit
in the dedicated seat (Fig. 14, Fig. 17, Fig. 23)
and connect it to the control panel of the indoor
unit as described in the relative instruction
booklet.
• M a n i f o l d s o l a r p r o b e e l e c t r i c a l
connection (optional).
Install the manifold solar probe (supplied in the
optional kit) and connect it to the solar control
unit.
• Solar control unit electrical connection (op-
tional).
Connect the solar control unit to the system as
indicated in the relative instructions manual.