Safety, Conventions, Trademarks Conventions Common Terms This is a list of symbols and abbreviations used in this manual. Symbol What it means Screw Connector E-ring Clip ring Harness clamp Flexible Film Cable Junction Gate Leading Edge of paper Long Edge Feed Short Edge Feed Trailing Edge of paper [A] Short Edge Feed (SEF)
Warnings, Cautions, Notes In this manual, the following important symbols and notations are used. • A Warning indicates a potentially hazardous situation. Failure to obey a Warning could result in death or serious injury. • A Caution indicates a potentially hazardous situation. Failure to obey a Caution could result in minor or moderate injury or damage to the machine or other property.
TABLE OF CONTENTS Safety, Conventions, Trademarks........................1 Conventions..............................1 Common Terms............................1 Warnings, Cautions, Notes...........................2 Responsibilities of the Customer Engineer....................2 Reference Material for Maintenance....................2 The Aim of Anti-tip Components and Precautions..................2 1. Replacement and Adjustment Detaching the Bridge Unit..........................5 Detaching the Upstream Unit.........................5 Detaching From the Downstream Unit......................
1. Replacement and Adjustment Detaching the Bridge Unit Detach the bridge unit [B] from the upstream unit [C] and downstream unit [A]. • If 2 vacuum feed LCITs are connected or 3 vacuum feed LCITs are connected, you can detach the bridge unit with the same procedure.
Page 8
1. Replacement and Adjustment Open the front door of the upstream unit and then remove the lock screw ( x2). Remove the rear cover of the upstream unit and then remove the screw of the joint bracket ( x1). ta-c2p2_sm_d778_00165759_eng.xml...
Detaching the Bridge Unit Detach the upstream unit [B] from the bridge unit [A] while pulling the lock bar on the back of the lock screw (the part indicated with the blue arrow should be pulled towards the front). Detaching From the Downstream Unit Remove the screw of the upper joint bracket ( x2).
Page 10
1. Replacement and Adjustment Plate [A] ( Remove the screw of the lower joint bracket ( x2). Rear cover [A] ( ta-c2p2_sm_d778_00165759_eng.xml...
Page 11
Detaching the Bridge Unit Disconnect all connectors connected to the downstream unit ( x5). Detach the bridge unit from the downstream unit. ta-c2p2_sm_d778_00165759_eng.xml...
Bridge Unit LCIT Connect Entrance Sensor Remove the two plates [A] [B] from the right side of the bridge unit ( x8). Sensor bracket [A] ( LCIT connect entrance sensor [A]( x1, x1) ta-c2p2_sm_d778_00165768_eng.xml...
1. Replacement and Adjustment LCIT Connect Exit Sensor Detach the bridge unit from the downstream unit (page 7 "Detaching From the Downstream Unit"). Sensor bracket [A] ( LCIT connect exit sensor [A]( x1, x1) ta-c2p2_sm_d778_00165768_eng.xml...
Horizontal Transport Unit Horizontal Transport Unit Horizontal Transport Entrance, Middle, Exit Sensor There are the horizontal transport sensors on the horizontal transport unit of the vacuum feed LCIT. [A]: Horizontal transport entrance sensor [B]: Horizontal transport middle sensor [C]: Horizontal transport exit sensor Pull the horizontal transport unit from the vacuum feed LCIT.
1. Replacement and Adjustment Horizontal Transport Entrance Motor The horizontal transport entrance motor is in the rear side of the vacuum feed LCIT. Remove the rear covers [A] [B] from the vacuum feed LCIT ( x15). Slide the plate [A] to left ( x1).
Horizontal Transport Unit Motor bracket [A] ( Horizontal transport entrance motor [A]( Horizontal Transport Exit Motor The horizontal transport exit motor is in the rear side of the vacuum feed LCIT. ta-c2p2_sm_d778_00165773_eng.xml...
Page 24
1. Replacement and Adjustment Remove the rear covers [A] [B] from the vacuum feed LCIT ( x15). Motor bracket [A] ( ta-c2p2_sm_d778_00165773_eng.xml...
Horizontal Transport Unit Horizontal transport exit motor [A] ( Control Board The control board is in the rear side of the vacuum feed LCIT. Remove the rear covers [A] [B] from the vacuum feed LCIT ( x15). ta-c2p2_sm_d778_00165773_eng.xml...
1. Replacement and Adjustment Control board [A] ( x5,all Cooling Fan The cooling fan is in the rear side of the vacuum feed LCIT. Remove the rear covers [A] [B] from the vacuum feed LCIT ( x15). ta-c2p2_sm_d778_00165773_eng.xml...
Page 27
Horizontal Transport Unit Cooling fan [A] ( ta-c2p2_sm_d778_00165773_eng.xml...