Chapter 7 _____________________________________________________________ Technical Data
VAISALA ________________________________________________________________________ 81
Table 15
Operating Environment
Property
Operating temperature range
Operating humidity range
Storage temperature range
Electromagnetic compliance
Table 16
Inputs and Outputs
Property
Current output models
Outputs
Loop resistance
Supply voltage
Max. power consumption
Typical power consumption
Voltage output models
Outputs
Load resistance
Supply voltage
Power consumption
Digital output models
Supply voltage
Max. power consumption
(with 120 Ω termination)
Output type
RS-485 end of line termination
Supported protocols
BACnet MS/TP
Operating mode
Address range, master mode 0 ... 127
Address range, slave mode
Modbus RTU
Address range
Service port
Table 17
Mechanics
Property
IP class
Standard housing color
Housing material
Output connector
Service port connector
Weight
*RAL code is only indicative with potential small variations in color shade.
Description / Value
-5 ... +55 °C (+23 ... +131 °F)
0 ... 95 %RH
Dewpoint <30 °C (+86 °F)
-30 ... +60 °C (-22 ... +140 °F)
EN61326-1, Industrial Environment
Description / Value
0/4 ... 20 mA
2 and 3 channel models available
0 ... 600 Ω
18 ... 35 VDC
24 VAC ± 20% 50/60 Hz
<2 W pulsed (outputs 3×21mA)
<1.2 W pulsed (outputs 3×12 mA)
0 ... 5/10 V
2 and 3 channel models available
10 kΩ min.
18 ... 35 VDC
24 VAC ± 20% 50/60 Hz
<1 W pulsed (output load 3×10 kΩ)
18 ... 35 VDC
24 VAC ±20 % 50/60 Hz
<1.5 W pulsed
RS-485 (galvanic isolation, 1.5 kV)
Enable with jumper, 120 Ω
Selectable by DIP switch
Selectable Master/Slave
128 ... 255
0 ... 247
RS-485 line
for temporary service use
Description / Value
IP30
White (RAL9003*)
ABS/PC, UL-V0 approved
Screw terminals
2
max. wire size 2 mm
4-pin M8
163 g
(AWG14)