4.8 Configuration and Calibration Command List

Following is a list of commands which will operate in the ADJ mode using Hyper
Terminal.
Top Level Menu
ADJ <enter>
Q <enter>
Sub-Menu
NOTES:
1. Backspace does not function. If a typing error occurs hit <enter> and begin again.
2. 1K altitude values 90 to 99 in EEPROM contain factory calibration data and are not
customer accessible.
3. A maximum error of ±499 feet may be introduced at any one altitude.
4. CLR clears all error data in the EEPROM.
5. ERR indicates syntax error.
Enter Adjustment mode.
Quit and return to normal operating mode.
CLR <enter>
D <enter>
P <enter>
Pabc<enter>
Q <enter>
Saa<enter>
Clear all EEPROM data.
Dump to list all EEPROM data.
Displays current serial Port settings, see § 4.6 Serial
Port Software Configuration.
Port protocol select, see §4.6 Serial Port Software
Configuration.
Quit and return to top level menu.
Set digitizer to 1K altitude (aa) mark at current input
pressure.
-21-