Antigl (Anti-Freeze Level); Zona (Function Not Present On This Model); Manutz (Programmed Maintenance); Association Procedure In Rf - Immergas CAR V2 Wireless Instruction And Warning Book

Modulating remote control
Hide thumbs Also See for CAR V2 Wireless:
Table of Contents

Advertisement

12.3

ANTIGL (anti-freeze level).

Allows to set the room temperature for activation of the
anti-freeze function. Can be regulated from 0°C to 10°C
and is set at 5°C as standard.
12.4

ZONA (function not present on this model).

12.5

MANUTZ (programmed maintenance).

Sets the period for periodic maintenance (can be set from 6
to 24 months or "Off "). When the period has been set, the
telephone number that the user must contact to perform
periodic maintenance is set.
12.6

Association procedure in RF.

To carry out an association in radio frequency between the
CAR
and the relative Base, follow that reported below:
V2
1) Access the protected menu of the CAR
management (radio frequency): CODE via code "9977";
2) The Test-RF menu will appear (RF>CHK);
3) By pressing the OK button, the RF>INS association/
installation menu will appear (if they are not already
associated, otherwise the RF>REM disassociation menu
will appear);
4) Within 30 seconds, activate the association stand-by
function on the Base by pressing the "test" button for at
least 4 seconds until the left LED on the base flashes;
5) Press the OK button on the CAR
association request;
6) If the procedure should fail, RF>INS will appear on
the CAR
successful, RF>REM will appear and one or more signals
will appear on the Base every 2 s;
7) At the end of the association procedure, wait at least 1
minute before regulating for communication between the
Base of the CAR
12.7

RF disassociation procedure.

To carry out a disassociation in radio frequency between
for RF
V2
the CAR
V2
1) Access the protected menu of the CAR
(radio frequency): CODE via code "9977";
2) The Test-RF menu will appear (RF>CHK);
3) By pressing the OK button, the RF>REM disassociation/
removal menu will appear (if they are associated,
otherwise the RF>INS association menu will appear);
once again, otherwise, if the procedure is
V2
and the boiler to be established.
V2
and the relative Base, follow that reported below:
to launch the
V2
for RF management
V2
33