7.2

Automatic functioning.

The CAR
allows automatic functioning, in which a
V2
program manages the room temperature during the hours
of the day.
The desired room temperature can be adjusted onto two
independent levels: comfort ( ) and economy ( ) via the
button, whose distribution throughout the day or the
week is managed by hourly programming.
Press the button
the display
.
The CAR
is factory-set with a standard program stated in
V2
the table that follows. If this should not satisfy requirements,
it is possible to modify it as described in the chapter relative
to programming.
24
until the icon switches-on on
Fig. 7-3
Days
40°C
Mon - Fri
from 23 to 11
(Day 1 - 5)
from 13 to 17
Sat - Sun
from 23 to 13
(Day 6 -7)
Note: the system is designed to function on comfort
and economy temperature levels depending on the hour
program set. Therefore also during functioning in economy
temperature conditions, if the room temperature measured
is above that set, the chiller can switch-on.
7.3

Forced automatic functioning.

If in automatic functioning mode ( ) the room temperature
is modified by pressing the + / - buttons, the forced automatic
functioning mode is activated (displayed by the switch-on of
the flashing symbol). In this mode, the room temperature
will be regulated to the value set until the next switch-on or
switch-off phase of the automatic program set. The forced
automatic function can be interrupted by simply pressing
the
button.
25°C
11 to 13
from
17 to 23
from
13 to 23
from
Fig. 7-4