THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WATER LINES
IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM
THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN, CREATING AN
ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE
WATER. THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS INDICATED. ANY DRAIN
FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE
FOUNTAIN FROM THE BUILDING PLUMBING SYSTEM. WE SUGGEST THAT THE BOTTLE FILLING STATION
AND WATER COOLER BE PROTECTED BY A GROUND FAULT CIRCUIT INTERRUPTER (GFCI).
INSTALLER
To insure you install this Kit easily and correctly, PLEASE READ THESE
SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK
YOUR INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL, AND
OTHER APPLICABLE CODES.
RETROFIT KIT EZS TO EZO
IMPORTANT! INSTALLER PLEASE NOTE.
1000005817
INSTALLATION MANUAL
THIS IS AN INDOOR APPLICATION ONLY.
ALL SERVICE TO BE PERFORMED BY AN
AUTHORIZED SERVICE PERSON.
GLOVES
SAFETY GLASSES
NEEDLE NOSE AND REGULAR PLIERS
¼ AND 5/16 NUT DRIVERS
FLAT HEAD SCREWDRIVER
T-20 TORX BIT OR 7/64 ALLEN WRENCH
BLACK MARKER
BUCKET
MULTI-METER
Page 1
IMPORTANT
TOOLS REQUIRED
BUT NOT PROVIDED:
1000005818 (Rev. A - 06/20)

Advertisement

loading

Summary of Contents for Elkay RETROFIT EZS Series

  • Page 1 1000005817 INSTALLATION MANUAL RETROFIT KIT EZS TO EZO IMPORTANT THIS IS AN INDOOR APPLICATION ONLY. ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON. TOOLS REQUIRED BUT NOT PROVIDED: GLOVES SAFETY GLASSES NEEDLE NOSE AND REGULAR PLIERS ¼ AND 5/16 NUT DRIVERS FLAT HEAD SCREWDRIVER T-20 TORX BIT OR 7/64 ALLEN WRENCH BLACK MARKER...
  • Page 2 1000005817 WATER COOLER PREPARATION ● Remove Lower wrapper on the cooler by removing the (4) screws using a 5/16 nut driver ● Shut off water to the cooler ● Remove water pressure by pressing on any of the cooler push bars until no water comes out of the bubbler ●...
  • Page 3 1000005817 12. Remove the white wire from the compressor relay and the black wire from the overload. Leave the fan wires connected. Fig 5 & 6 Fig. 5 Fig. 6 13. Remove the power cord ground connection on the frame using the ¼ nut driver. Keep this screw it will be needed to connect the ground wire on the new power cord.
  • Page 4 1000005817 14. Using pliers, squeeze the strain relief on the power cord and pull down to remove the cord from the bracket. Fig 8 15. Remove all remaining wires from the solenoid and cold control and discard. Fig. 8 16. Measure 23 inches from the plug end of the power cord and place the strain relief on the cord at that point.
  • Page 5 1000005817 18. Put the ground screw in the ring terminal on the green ground wire on the power cord. Tighten the screw back into the frame where the old ground wire was connected. Tighten the screw so that the terminal will not turn. To make sure that the grounding connection is secure, use a multi-meter and check for continuity.
  • Page 6 1000005817 21. Replace the cover over the compressor electricals. Place the slot on the cap on the lower arm on the compressor, slide all the wire into the large slot in the cap. Rotate the cap upwards and push until it snaps into place. Fig. 14a, 14b & 14c Fig.
  • Page 7 FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.834.4816 PRINTED IN U.S.A. REPAIR SERVICE INFORMATION TOLL FREE NUMBER 1.800.260.6640 ELKAY MANUFACTURING COMPANY • 1333 BUTTERFIELD ROAD SUITE 200 DOWNERS GROVE, IL 60515 • 630.574.8484 • www.elkay.com Page 7 1000005818 (Rev. A - 06/20)

This manual is also suitable for:

Retrofit ezo series