Unit conversion

The following factors can be used to convert from English to the most common SI metric values.
Table 10: SI metric conversion
Measurement
Capacity
Power
Flow rate
Length
Weight
Velocity
Pressure drop
Temperature
To convert degrees Fahrenheit (°F) to degrees Celsius (°C), subtract 32° and multiply by 5/9 or
0.5556.
Example: (45.0°F - 32°) x 0.5556 = 7.22°C
To convert a temperature range (i.e., a range of 10°F) from Fahrenheit to Celsius, multiply by 5/9 or
0.5556.
Example: 10.0°F range x 0.5556 = 5.6°C range
© 2021 Johnson Controls. 5000 Renaissance Drive, New Freedom, York, PA 17349, USA. Subject to change without notice. All
rights reserved.
Multiply English unit
Tons refrigerant effect (ton)
Horsepower
Gallons / minute (gpm)
Feet (ft)
Inches (in.)
Pounds (lb)
Feet / second (fps)
Feet of water (ft)
Pounds / square inch (psi)
By factor
To obtain metric unit
3.516
Kilowatts (kW)
0.7457
Kilowatts (kW)
0.0631
Liters / second (L/s)
0.3048
Meters (m)
25.4
Millimeters (mm)
0.4536
Kilograms (kg)
0.3048
Meters / second (m/s)
2.989
Kilopascals (kPa)
6.895
Kilopascals (kPa)