Scope of delivery
OrderNumber
= "6DR410* / 6DR55**"
Info_Text
= "Electropneumatic positioner, PROFIBUS PA Profile 3.0"
Freeze_Mode_supp
= 0
Sync_Mode_supp
= 0
Auto_Baud_supp
= 0
Set_Slave_Add_supp
= 1
Min_Slave_Intervall = 200
Modular_Station
= 1
Max_Module
= 1
Max_Input_Len
= 15
Max_Output_Len
= 10
Max_Data_Len
= 25
Max_Diag_Data_Len
= 14
Fail_Safe
= 0
Max_User_Prm_Data_Len
Ext_User_Prm_Data_Const(0)
Ext_User_Prm_Data_Const(1)
Ext_User_Prm_Data_Const(2)
;----------- Description of extended DP features: ---------------------
;
DPV1_Slave
C2_Read_Write_supp
C2_Max_Data_Len
C2_Read_Write_required
C2_Max_Count_Channels
Max_Initiate_PDU_Len
C2_Response_Timeout
DPV1_Data_Types
;----------- Description of physical interface for synchronous transmission:
; IEC61158-2
Physical_Interface
Transmission_Delay_31.25
Reaction_Delay_31.25
End_Physical_Interface
;----------- Description of device related diagnosis: ---------------------
;
Unit_Diag_Bit(16)
= "Status appears"
Unit_Diag_Bit(17)
= "Status disappears"
Unit_Diag_Bit(24)
= "Hardware failure electronics"
Unit_Diag_Bit(25)
= "Hardware failure mechanics"
Unit_Diag_Bit(26)
= "Motor temperature too high"
Unit_Diag_Bit(27)
= "Electronic temperature too high"
Unit_Diag_Bit(28)
= "Memory error"
Unit_Diag_Bit(29)
= "Measurement failure"
Unit_Diag_Bit(30)
= "Device not initialised"
Unit_Diag_Bit(31)
= "Device initialisation failed"
Unit_Diag_Bit(32)
= "Zero point error"
Unit_Diag_Bit(33)
= "Power supply failed"
Unit_Diag_Bit(34)
= "Configuration invalid"
Unit_Diag_Bit(35)
= "Restart"
Unit_Diag_Bit(36)
= "Coldstart"
Unit_Diag_Bit(37)
= "Maintenance required"
Unit_Diag_Bit(38)
= "Characteristics invalid"
Unit_Diag_Bit(39)
= "Ident_Number violation"
Unit_Diag_Bit(55)
= "Extension available"
;------------------------------------------------------------------------------
;---------- Module Description -----------------------------------------
;Variables combination for Analog Output
;Abbreviations
; RB = READBACK, CB = CHECKBACK, RC_OUT = RCAS_OUT, RC_IN = RCAS_IN
;Identifier Bytes
Module
= "SP"
0 ; Module-Reference
154
; 0 = no Freeze Mode supported
; 0 = no Sync Mode supported
; 1 = Set Slave AddrFunction supported
; 20ms min. betw. 2 slave list cycles
; 1 = Modular Station
; 1: PA_AO
; maximum Input Length
; maximum Output Length
; maximum In-Output Length
= 3
= 0x00
;DPV1 Status 1, DPV1-Enable = 0
= 0x00
;DPV1 Status 2, no Alarms enabled
= 0x00
;DPV1 Status 3
= 0
= 1
= 128
= 1
= 4
= 52
= 4000
= 0
= 1
= 0
= 0
0xA4