1.37 CIRCULATION PUMP
(SOLAR THERMAL SYSTEM
COUPLING KIT).
The units are supplied with circulating
pumps fitted with speed regulator.
These settings are suitable for most
systems.
In fact, the pump is equipped with
electronic control to set advanced
functions. For proper operation one
must select the most suitable type of
operation for the system and select
a speed in the available range, with a
focus on energy savings.
Display of operation status. During
normal operation the status LED (2)
is on green (flashing (FL) when it is in
stand-by), the four yellow LEDs (3) in-
dicate circulator absorption according
to the following table:
Circulating pump
Absorption
LED
G
Y
Y
Y
Y
Circulator in
stand-by
FL Off Off Off Off
G
Y
Y
Y
Y
0 ÷ 25 %
On On Off Off Off
G
Y
Y
Y
Y
25 ÷ 50 %
On On On Off Off
G
Y
Y
Y
Y
50 ÷ 75 %
On On On On Off
G
Y
Y
Y
Y
75 ÷ 100 %
On On On On On
Selection of operating mode. To see
the current operation mode it is suffi-
cient to press button (1) once.
To change operation mode press the
button for between 2 to 10 seconds
until the current configuration flash-
ing, each time the button is pressed
all possible functions are scrolled
cyclically according to the table (Fig.
55). After a few seconds without doing
any operation the circulator memorises
the selected mode and goes back to
operation display.
- Constant curve: the pump operates
with a constant curve. The circulator
working point will move up or down
according to the system's demand.
- PWM profile: do not use this opera-
tion mode.
Circulating pump LED Description
G
Y
Y
Y
Y
Constant
curve speed 1
On On On Off Off
G
Y
Y
Y
Y
Constant
curve speed 2
On On On On Off
G
Y
Y
Y
Y
Constant
curve speed 3
On On On On On
Constant
G
Y
Y
Y
Y
curve speed 4
On On On Off On
(default)
55
47
Selection button lock. The button has
a feature that locks its operation to pre-
vent accidental modifications, to lock
the control panel it is necessary to press
button (1) longer than 10 seconds (dur-
ing which the current configuration
flashes), the active lock is signalled by
all LEDs of the control panel flashing.
To unlock the button press again longer
than 10 seconds.
Real time diagnostics: in the event
of malfunction the LEDs provide in-
formation on the circulator operation
status, see table (Fig. 56):
Key:
1 - Function selection button
2 - Green (G) / red (R) LED
3 - 4 yellow LEDs (Y)
DO NOT USE
Circulating pump LED Description
R
Y
Y
Y
Y
PWM Profile
speed 1
On Off On Off Off
R
Y
Y
Y
Y
PWM Profile
speed 2
On Off On On Off
R
Y
Y
Y
Y
PWM Profile
speed 3
On Off On On On
R
Y
Y
Y
Y
PWM Profile
speed 4
On Off On Off On