Zone Circulation Pump - Immergas SUPER TRIO Instructions And Warnings

Hide thumbs Also See for SUPER TRIO:
Table of Contents

Advertisement

1.36 ZONE CIRCULATION
PUMP.
The system is supplied with pumps
equipped with speed regulators.
These settings are suitable for most
systems.
Central heating/cooling system
pumps. The circulators are equipped
with electronic control that allows to
set advanced functions. For proper op-
eration one must select the most suita-
ble type of operation for the system and
select a speed in the available range.
The central heating/cooling system
pumps control the room central heat-
ing or cooling requests downstream of
the hydraulic manifold.
- Constant head (ΔP C) (Ref. 4 Fig.
50). The circulator pump maintains
the pressure level (head) constant as
the system heat demand decreases
(flow rate reduction).
LED
Description
Green (on)
Normal functioning
Green
Automatic vent in op-
(fast flashing)
eration
Abnormal situation
Red (on)
Circulator pump work-
Green (flashing)
ing but stationary
P u m p / C i r c u l a t o r
Red (flashing)
blocked
circulator pump not
LED (off)
working
With these settings, the circulator
pump is suitable for all floor sys-
tems where all the circuits must be
balanced for the same drop in head.
One can select the power level from a
minimum one to a maximum one by
turning the selector switch clockwise
in the relative power scale.
- Proportional head (ΔP V) (Ref. 3
Fig. 50). This allows the pressure
level (head) to be proportionally
reduced as the system heat demand
decreases (flow rate reduction).
Thanks to this function, the electric
power consumption of the circulator
pump is reduced further: the energy
(power) used by the pump decreases
according to the pressure level and
flow rate. With this setting, the pump
guarantees optimal performance in
most heating systems, proving par-
ticularly suitable in single-pipe and
two-pipe installations. Any noise
originating from the water flow in the
Key:
1 - Automatic vent mode operation
2 - Light ring to indicate the operating status
3 - Proportional head operation
4 - Constant head operation
5 - Operating mode selector switch
Diagnostics
The circulator pump
Air in circulator pump
vents for 10 minutes
a) voltage off range
The circulator pump re-
starts once the abnormal
b) high pump / circula-
situation has been solved
the circulator pump can-
check the circulator
not restart automatically
pump
due to an anomaly
a) pump / circulator not
electronics not powered
b) LED damaged
c) electronics damaged
44
pipes, valves and radiators is elimi-
nated by reducing the head. Optimal
conditions for thermal comfort and
acoustic well-being. One can select
the power level from a minimum one
to a maximum one by turning the
selector switch counterclockwise on
the relative power scale.
Adjustment. Turn the selector and
set it on the desired curve to adjust
the pump.
Automatic vent function (Ref. 1 Fig.
50). The circulator pump is equipped
with a function that activates its oper-
ation for 10 minutes, alternating the
speed between minimum and maxi-
mum, so that the air contained in the
circulator pump is expelled by the air
vent valve.
Diagnostics in real time: a light ring
(Ref. 2 Fig. 50) provides, in various
colours, information regarding the
pump operating status, see table below..
Cause
If the circulator pump requires
the automatic vent function often,
one must adjust the operating
mode properly.
a) check power supply
(160 ÷ 253V)
b) check temperature of room
and of the water contained in
tor temperature
the system
if the problem persists replace the
circulator pump
a) check the electrical connec-
tions
connected
b) check that the pump / circula-
tor is working
c) replace the pump / circulator
50