Immergas SUPER TRIO Instructions And Warnings
Immergas SUPER TRIO Instructions And Warnings

Immergas SUPER TRIO Instructions And Warnings

Hide thumbs Also See for SUPER TRIO:
Table of Contents

Advertisement

Quick Links

SUPER TRIO
Instructions and warnings
IE
Installer
User
Maintenance technician

Advertisement

Table of Contents
loading

Summary of Contents for Immergas SUPER TRIO

  • Page 1 SUPER TRIO Instructions and warnings Installer User Maintenance technician...
  • Page 3 Immergas Customer, you can also count on a qualified after-sales service, prepared and updated to guarantee constant efficiency of your "Super Trio" kit. Read the following pages carefully: you will be able to draw useful tips on the proper use of the device, compliance with which will confirm your satisfaction with the Immergas product.
  • Page 4: Table Of Contents

    Internal Unit........32 1.18 Main components Super Trio with Magis Combo Plus - Magis Combo Plus V2 Internal Unit..33 1.19 Super Trio with Single zone Kit (Supplied as standard)....34 1.20 Super Trio with Second mixed Zone Kit (Optional).......34 1.21 Main components solar heating...
  • Page 5: Installation

    The “Super Trio” for pack is not a sup- the supplier immediately. Packing ma- tion (via special optional kit). terials (staples, nails, plastic bags, poly- porting structure and cannot replace the piece of wall removed.
  • Page 6: Overall Dimensions

    1.4 OVERALL DIMENSIONS. Connection outdoor unit Height Width Depth (mm) (mm) (mm) 2200 1100 ATTENTION There is no possibility to go out on the left side with the flue kits and with the solar connection pipes.
  • Page 7: Connection Template

    1.5 CONNECTION TEMPLATE. Attention: the indicated values refer to the stickers applied inside the recessed frame. REAR CONNECTION RIGHT HAND SIDE CONNECTION LOWER CONNECTION ATTENTION In the references in the boiler instructions manual, the mixed zone corresponds to zone 2 while the direct zone corresponds to zone 1 Key: ZONE CONNECTION TABLE.
  • Page 8: Installation

    1.6 INSTALLATION. Installation drawings key: Pack composition. Unmistakeable component identification Ref. Description Q.ty Storage tank / Cylinder Storage tank Sequential identification of the operation to perform Single zone hydronic group Accessories and screws Identification of generic or not supplied component...
  • Page 9 This kit ensures to envision the space for the six slots a suitable support only if inserted cor- • The Super Trio is closed by the side for inserting the respective support rectly (according to the rules of good...
  • Page 10 • Insert the storage tank (a) into the Su- taining strip (d1) on the screws fitted per Trio with the flange positioned on on the Super Trio. the right hand side and at the bottom, as shown in Fig. 7.
  • Page 11 • Bend the strip (d1) around the storage tank (a) and fasten it with the screw (E) (Fig. 8).
  • Page 12 • Hang the storage tank (b) on the Secure the position of the storage tank Attention: the fixing screws (d2) are central bracket on the Super Trio. by tightening the screws (d2) on the present inside the connection kit. provided bracket (Fig. 9).
  • Page 13 Magis Pro - Magis Pro V2 Internal • Make the hydraulic connection remembering to insert the special Unit installation operations. between the storage tank (a), single gaskets supplied. • Tighten the bracket (H) to the special zone hydronic unit (c) and Magis Pro N.B.
  • Page 14 Dett. 1 Det. 1 Dett. 2 Det. 2...
  • Page 15 Det. 1 Det. 2 FLEXIBLE PIPE...
  • Page 16 Magis Combo Plus - Magis Combo • Make the hydraulic connection be- remembering to insert the special Plus V2 Internal Unit installation tween the storage tank (a), single zone gaskets supplied. operations. hydronic unit (c) and Magis Combo N.B. (Fig. 18): remove the grid and the •...
  • Page 17 Dett. 3 Det. 3 Dett. 4 Det. 4...
  • Page 18 Det. 3 Det. 4 FLEXIBLE PIPE...
  • Page 19 Installation operations SOLAR - Connect the two solar system pipes to HEATING SYSTEM COUPLING the specially arranged fittings, using KIT. one of the pre-cut slots (L). - Close the cold water inlet upstream - Fit the fitting of the safety valve. Con- of the system and empty the storage nect the silicone pipe (5) to the fitting tank / cylinder.
  • Page 20 FLOW FROM RETURN TO PANEL PANEL...
  • Page 21: Magis Pro V2 Internal Unit

    1.7 CONNECTION WIRING block / terminal board (see wiring - Connect the connector with the green DIAGRAM SINGLE ZONE diagram Fig. 30 - 31) and position it “M-Z2” label to the pump / circulator HYDRONIC KIT (SECOND on the storage tank in the appropriate (8) (Only if the second optional zone ZONE OPTIONAL) AND seat (Fig.
  • Page 22: Plus V2 Internal Unit

    terminals (4) to the device terminal - Connect the connector with the green 1.8 CONNECTION WIRING DIAGRAM SINGLE ZONE block / terminal board (see wiring “M-Z2” label to the pump / circulator HYDRONIC KIT (SECOND diagram Fig. 32 - 33) and position it (8) (Only if the second optional zone on the storage tank in the appropriate is present).
  • Page 23: Gas Connection

    3 bar Magis safety valve. referring to the connection template on Connect the silicone pipe (d8) to the the Super Trio and to the Internal Unit hose union (d7) in the Internal Unit operation and maintenance manual. and, after having cut it to size, insert it into the funnel (d6) as shown in Fig.
  • Page 24: Electrical Connection

    Make the connection as indicated in must never be used for earthing the The Super Trio pack has an IPX5D the external unit instruction book. electrical or telephone system. Make protection rating. Electrical safety of •...
  • Page 25 Magis Pro Connection.
  • Page 26 Magis Pro V2 Connection.
  • Page 27 Magis Combo Plus Connection.
  • Page 28 Magis Combo Plus V2 Connection.
  • Page 29: Room Chrono-Thermostats And Remote Controls (Optional)

    1.14 ROOM CHRONO- THERMOSTATS AND REMOTE CONTROLS (OPTIONAL). See the Internal Unit instruction booklet. 1.15 SOLAR CONTROL UNIT INSTALLATION (OPTIONAL). If necessary, it is possible to remove the contact cover, by undoing the relevant fixing screw (Fig. 34) and access the connections area (Fig.
  • Page 30 Block function. Maximum manifold temperature. Antifreeze protection. To prevent errors after installation, all “ColM” parameter (default value “120”). “FrEZ” parameter (default value “off ”) the critical parameters (system and Ex- - Set the level to start the overheating This option maintains the temperature tra function) cannot be accessed when protection for the manifold.
  • Page 31: Antifreeze Protection

    1.16 ANTIFREEZE - Maximum temperature in tank 1. PROTECTION. “TkM1” parameter (default value Assembly instructions. “65°C”). - Wind the heating cable (d9) around - Maximum value of the desired tem- the connection pipes and safety valve. perature of the water in tank 1 dur- Attention: the graphic representation ing normal operation.
  • Page 32: Internal Unit

    1.17 MAIN COMPONENTS SUPER TRIO WITH MAGIS PRO - MAGIS PRO V2 INTERNAL UNIT. Key: 1 - Storage tank draining cock / tap 2 - Sacrificial anodes 3 - 8 bar safety valve 4 - Solar probe (optional) 5 - Antifreeze thermostat...
  • Page 33: Main Components Super Trio With Magis Combo Plus - Magis Combo Plus V2 Internal Unit

    1.18 MAIN COMPONENTS SUPER TRIO WITH MAGIS COMBO PLUS - MAGIS COMBO PLUS V2 INTERNAL UNIT Key: 1 - Storage tank draining cock / tap 2 - Sacrificial anodes 3 - 8 bar safety valve 4 - Solar probe (optional)
  • Page 34: Super Trio With Single Zone Kit

    1.19 SUPER TRIO WITH SINGLE ZONE KIT (SUPPLIED AS STANDARD) Key: 1 - Drain fitting 2 - Manifold 3 - Cap 4 - Cap 1.20 SUPER TRIO WITH SECOND MIXED ZONE KIT (OPTIONAL).
  • Page 35: Main Components Solar Heating System Coupling Kit (Optional)

    1.21 MAIN COMPONENTS SOLAR HEATING SYSTEM COUPLING KIT (OPTIONAL). Key: 1 - Expansion vessel / Expansion tank 2 - Solar control unit 3 - Plate heat exchanger 4 - Circulation unit 5 - Safety valve 6 - Can 7 - Interception cock...
  • Page 36: Hydraulic Diagram With Magis Pro - Magis Pro V2 Internal Unit

    1.22 HYDRAULIC DIAGRAM WITH MAGIS PRO - MAGIS PRO V2 INTERNAL UNIT. Key: 8 - DHW probe AC - Domestic hot water outlet 1 - Storage tank / Cylinder 9 - Direct zone pump AF - Domestic cold water inlet 2 - Condensing unit 10 - One-way valve MZ1 - High temperature system flow...
  • Page 37: Hydraulic Diagram With Magis Combo Plus - Magis Combo Plus V2 Internal Unit

    1.23 HYDRAULIC DIAGRAM WITH MAGIS COMBO PLUS - MAGIS COMBO PLUS V2 INTERNAL UNIT. Key: 8 - DHW probe AC - Domestic hot water outlet 1 - Storage tank / Cylinder 9 - Direct zone pump AF - Domestic cold water inlet 2 - Condensing unit 10 - One-way valve MZ1 - High temperature system flow...
  • Page 38: Hydraulic Diagram Connection With Magis Pro - Magis Pro V2 Internal Unit W Ith Second Mixed Zone Kit

    1.24 Key: AC - Domestic hot water outlet 1 - 3-way Mixing valve 2 - Safety thermostat AF - Domestic cold water inlet 3 - Mixed zone pump / circulator MZ2 - Low temperature system flow RZ2 - Low temperature system return 4 - System flow probe low temperature MZ1 - High temperature system flow...
  • Page 39: Hydraulic Diagram Connection With Magis Combo Plus - Magis Combo Plus V2 Internal Unit With Second Mixed Zone Kit

    1.25 HYDRAULIC DIAGRAM CONNECTION WITH MAGIS COMBO PLUS - MAGIS COMBO PLUS V2 INTERNAL UNIT WITH SECOND MIXED ZONE KIT. Key: AC - Domestic hot water outlet 1 - 3-way Mixing valve 2 - Safety thermostat AF - Domestic cold water inlet 3 - Mixed zone pump / circulator MZ2 - Low temperature system flow RZ2 - Low temperature system return...
  • Page 40: System Coupling Kit (Optional)

    1.26 HYDRAULIC DIAGRAM SOLAR HEATING SYSTEM COUPLING KIT (OPTIONAL). Key: 1 - Storage tank / Cylinder AC - Domestic hot water outlet 2 - 18 L Solar expansion vessel AF - Domestic cold water inlet 3 - 6 bar Safety valve assembly MU - Storage tank unit flow 4 - Solar circulation unit RU - Storage tank unit return...
  • Page 41: Mixing Valve

    1.27 MIXING VALVE. 1.31 COMMISSIONING - check connection to a 230V-50Hz The Internal Unit is equipped with a SOLAR HEATING power mains, correct L-N polarity and mixing valve that regulates the storage SYSTEM COUPLING KIT the earthing connection; tank / cylinder outlet temperature. (OPTIONAL).
  • Page 42: (Optional)

    The system must be filled using only Solar hydraulic unit safety valve. pack or Internal Unit manometer / the glycol supplied by Immergas via an There is a safety valve present on the pressure gauge indicates approx. 1.2 automatic pump. The system must be hydraulic unit that protects the system bar.
  • Page 43: Sizing The Systems

    (second zone) for switch the filling pump off, open coupling the Internal Unit inside the the adjustment screw of the flow Super Trio. rate regulator (notch in vertical position). The above-mentioned kits are supplied complete with instructions for assem- 8 Leave the circuit pressurised.
  • Page 44: Zone Circulation Pump

    1.36 ZONE CIRCULATION pipes, valves and radiators is elimi- With these settings, the circulator PUMP. pump is suitable for all floor sys- nated by reducing the head. Optimal The system is supplied with pumps tems where all the circuits must be conditions for thermal comfort and equipped with speed regulators.
  • Page 45 Head available at the system high temperature zone, low temperature zone with mixer open (optional kit). Constant head (ΔP C). Key: A = Available head B = Absorbed power by the circulator (dotted area) 1000 1200 1400 1600 1800 2000 2200 2400 Flow rate (l/h)
  • Page 46 Head available to the system (direct zone) Constant head (ΔP C). Key: 1000 1200 1400 1600 1800 2000 2200 2400 A = Available head Flow rate (l/h) B = Absorbed power by the circulator (dotted area) Proportional head (ΔP V). 1000 1200 1400...
  • Page 47: Mal System Coupling Kit)

    1.37 CIRCULATION PUMP Selection of operating mode. To see Selection button lock. The button has (SOLAR THERMAL SYSTEM the current operation mode it is suffi- a feature that locks its operation to pre- COUPLING KIT). cient to press button (1) once. vent accidental modifications, to lock The units are supplied with circulating the control panel it is necessary to press...
  • Page 48 Circulating pump Description Diagnostics Remedy (first red LED) Wait for the circulator to make auto- matic release attempts or manually The circulator pump cannot release the motor shaft acting on the Pump / Circulator blocked restart automatically due to screw in the centre of the head. On Off Off Off On an anomaly If the anomaly persists replace the...
  • Page 49: Instructions For Use And Maintenance

    INSTRUCTIONS FOR USE 2.2 GENERAL WARNINGS. 2.3 DECOMMISSIONING. AND MAINTENANCE. The device can be used by children at In the event of permanent shutdown least 8 years old as well as by persons of the pack, contact professional staff 2.1 CLEANING AND with reduced physical, sensory or men- for the procedures and ensure that the MAINTENANCE.
  • Page 50: Control And Maintenance

    CONTROL AND MAINTENANCE. - Using an omnipolar disconnector, check connection to 230V-50Hz mains power supply, correct L-N polarity and the earthing connection; - make sure the central heating system is filled with water and that the ma- nometer of the Internal Unit indicates a pressure of 1÷1.2 bar;...
  • Page 51: Yearly Maintenance

    3.3 YEARLY MAINTENANCE. - Service the Internal Unit according to 3.4 DECOMMISSIONING. - Check the integrity of the storage tank the guidelines in the relative instruc- In the event of permanent system / cylinder magnesium anode. tion booklet. shutdown, contact professional staff for the procedures and ensure that the - Check tightness of the assembly ele- - Service the External Unit according to...
  • Page 52: Technical Data

    3.5 TECHNICAL DATA. Maximum central heating circuit pressure Maximum domestic hot water circuit pressure Max. central heating circuit temperature °C Max. domestic hot water circuit operating temperature °C DHW expansion vessel 16.0 DHW expansion vessel pre-charged pressure Water content in the storage tank Full hydronic unit weight Empty hydronic unit weight 26.3...
  • Page 53: Product Fiche (In Compliance With Regulation 812/2013)

    (for the installer) and current installation regulations. For proper maintenance refer to chapter 3 of this booklet (for the maintenance technician) and adhere to the frequencies and methods set out herein. SUPER TRIO Storage tank unit "!! 2017 812/2013...
  • Page 56 Standards in force. N.B.: correct periodic maintenance is highly recommended. Immergas TOOLBOX The App designed by Immergas for professionals Disponibile su Disponibile su Disponibile su immergas.com To request further specific details, sector Professionals can also use the following e-mail address: consulenza@immergas.com...

Table of Contents