22 December 1998
3. INSTALLATION
3.1 ENVIRONMENT
3.1.1 PRECAUTIONS
Please observe the following precautions in order to ensure safe operation of the
scanner and to realize its full performance.
• Ambient illumination must be less than 2,000 lux (do not expose to direct
sunlight).
• Do not use the scanner in any location that is exposed to frequent vibration.
• Do not expose the scanner to dusty or corrosive atmospheric conditions.
• Ensure that the area in which the scanner is used is well ventilated (30
3
m
/hr/person).
• Make sure that the surface on which you place the scanner is stable and level.
3.1.2 ENVIRONMENTAL CONDITIONS
Temperature: 10°C to 32°C (50 to 90°F)
Humidity:
20 to 80 %
3.1.3 MACHINE LEVEL
1. Front to back: Within 5 mm (0.2") of level
2. Right to left:
Within 5 mm (0.2") of level
3.1.4 MINIMUM SPACE REQUIREMENTS
Place the scanner near a power source, providing clearance as shown.
A: 10 mm (0.2")
B
B: 30 mm (1.2")
A
C
C: 600 mm (23.7")
3-1
ENVIRONMENT
D
G411I500.WMF