Immergas VICTRIX PRO 1 I Series Technical Sheet

Immergas VICTRIX PRO 1 I Series Technical Sheet

Wall-hung modular condensing boilers for high power
Table of Contents

Advertisement

VICTRIX PRO 1 I
Wall-hung modular condensing
boilers for high power

Advertisement

Table of Contents
loading

Summary of Contents for Immergas VICTRIX PRO 1 I Series

  • Page 1 VICTRIX PRO 1 I Wall-hung modular condensing boilers for high power...
  • Page 3: Table Of Contents

    INDEX INDEX TABLE OF CONTENTS 1 VICTRIX PRO 35 1 I-55 1 I SPECIFICATIONS ..........................5 2 VICTRIX PRO 80 1 I-100 1 I-120 1 I SPECIFICATIONS ......................6 VICTRIX PRO 35 1 I-55 1 I MAIN PARTS ...........................7 4 VICTRIX PRO 80 1 I-100 1 I-120 1 I MAIN PARTS ........................8 5 VICTRIX PRO 35 1 I-55 1 I MAIN MEASUREMENTS .......................9 6 VICTRIX PRO 80 1 I MAIN MEASUREMENTS ........................10 7 VICTRIX PRO 100 1 I-120 1 I MAIN MEASUREMENTS......................11...
  • Page 4 With single or cascade installation, VICTRIX PRO 1 I can be ing and for cascade configuration (up to 5 appliances), with the combined with IMMERGAS solar solutions for the production advantage of guaranteeing higher overall output and reduced of domestic hot water, especially with storage tank units of 200, running costs.
  • Page 5: Victrix Pro 35 1 I-55 1 I Specifications

    • control panel supplied with P.C.B. with microprocessor with continuous flame modulation on heating with P.I.D. control, NOTA BENE: for correct installation of the boiler the Immergas modulation field referring to 50/30 °C between: "Green Range" air intake/fumes exhaust kit must be used and 3.7 and 37.3 kW (between 3.208 and 32.155 kcal/h) for...
  • Page 6: Victrix Pro 80 1 I-100 1 I-120 1 I Specifications

    8.1 to 80.3 kW (between 6.983 and 68.994 kcal/h) VICTRIX PRO 80 1 I; NOTA BENE: for correct installation of the boiler the Immergas 10.5 to 98.8 kW (between 9.023 and 84.942 kcal/h) "Green Range" air intake/fumes exhaust kit must be used and VICTRIX PRO 100 1 I;...
  • Page 7: Victrix Pro 35 1 I-55 1 I Main Parts

    VICTRIX PRO 35 1 I - 55 1 I VICTRIX PRO 35 1 I-55 1 I MAIN PARTS KEY: 16 - Fumes hood - P.C.B. 17 - Manual air vent valve 18 - Condensation module - Gas valve 19 - Heat exchanger safety thermal fuse - Gas nozzle - Sleeve with seats for Venturi 20 - Burner...
  • Page 8: Victrix Pro 80 1 I-100 1 I-120 1 I Main Parts

    VICTRIX PRO 80 1 I -100 1 I - 120 1 I VICTRIX PRO 80 1 I-100 1 I-120 1 I MAIN PARTS KEY: - Draining funnel. 15 - Ignition electrode - Gas cock 16 - Heat exchanger safety thermal fuse - Pump 17 - Detection electrode - Gas nozzle...
  • Page 9: Victrix Pro 35 1 I-55 1 I Main Measurements

    VICTRIX PRO 35 1 I - 55 1 I VICTRIX PRO 35 1 I-55 1 I MAIN MEASUREMENTS Model Height mm Width mm Depth mm VICTRIX PRO 35 1 I - 55 1 I CONNECTIONS Cover upper line SC = Condensate drain Ø 25 mm Distance between cover upper line and Distance between cover upper line and Ø...
  • Page 10: Victrix Pro 80 1 I Main Measurements

    VICTRIX PRO 80 1 I -100 1 I - 120 1 I VICTRIX PRO 80 1 I MAIN MEASUREMENTS Model Height mm Width mm Depth mm VICTRIX PRO 80 1 I 1038 CONNECTIONS Cover upper line SC = Condensate drain Ø 25 mm Distance between cover upper line and Distance between cover upper line and Ø...
  • Page 11: Victrix Pro 100 1 I-120 1 I Main Measurements

    VICTRIX PRO 80 1 I -100 1 I - 120 1 I VICTRIX PRO 100 1 I-120 1 I MAIN MEASUREMENTS Model Height mm Width mm Depth mm VICTRIX PRO 100 1 I-120 1 I 1038 CONNECTIONS Cover upper line SC = Condensate drain Ø...
  • Page 12: Hydraulic Kit Measurements And Fittings (Optional) With Single Victrix Pro 35 1 I-55 1 I Boiler

    Immergas S.p.a. declines all liability whenever the installer does with 4-bar safety valve and standard draining funnel). not use approved devices and Immergas original kits or uses There is a fitting for an expansion vessel on the flow and return them improperly.
  • Page 13: Hydraulic Kit Measurements And Fittings (Optional) With Single Victrix Pro 80 1 I-100 1 I-120 1 I Boiler

    Immergas S.p.a. declines all liability whenever the installer does with 4-bar safety valve and standard draining funnel). not use approved devices and Immergas original kits or uses There is a fitting for an expansion vessel on the flow and return them improperly.
  • Page 14: Safety Device Kit For Single Boiler For Victrix Pro 35 1 I - 55 1 I - 80 1 I - 100 1 I - 120 1 I

    Immergas declines all liability whenever the installer does not stub pipes. use original Immergas devices and kits, or uses them improperly. The sensitive elements of the safety devices must be set up as described in the installation instructions, in compliance with the provisions cascade forth in the ''R'' collection.
  • Page 15: Three-Way Valve Kit For Combination With Separate Storage Tank Unit For Victrix Pro

    VICTRIX PRO 1 I 11 THREE-WAY VALVE KIT FOR COMBINATION WITH SEPARATE STORAGE TANK UNIT (CODE 3.023950) FOR VICTRIX PRO 35 1 I - 55 1 I - 80 1 I - 100 1 I - 120 1 I The kit is sized for single boiler operation or in combination any pre-installed temperature probe from the storage tank unit.
  • Page 16: Hydraulic Separator Kit For Individual Boiler Victrix Pro 35 1 I - 55 1 I

    HYDRAULIC SEPARATOR KIT FOR INDIVIDUAL BOILER VICTRIX PRO 35 1 I - 55 1 I (CODE 3.023951) The hydraulic separator (compensator) is a particularly signif- The brass sludge collecting filter, with relative inspectable icant part inside the hydraulic circuits. stainless steel cartridge, protects the condensation module from It is an open manifold (2) which places system flow and return getting clogged with the sludge or build-up from the system.
  • Page 17: Hydraulic Separator Kit For Individual Boiler Victrix Pro 80 1 I - 100 1 I - 120 1 I

    VICTRIX PRO 80 1 I -100 1 I - 120 1 I HYDRAULIC SEPARATOR KIT FOR INDIVIDUAL BOILER VICTRIX PRO 80 1 I - 100 1 I - 120 1 I (CODE 3.023952) The hydraulic separator (compensator) is a particularly signif- The brass sludge collecting filter, with relative inspectable icant part inside the hydraulic circuits.
  • Page 18: 14 Victrix Pro 35 1 I - 55 1 I Adapter Kit In Replacement Of The Previous One

    14 VICTRIX PRO 35 1 I - 55 1 I ADAPTER KIT IN REPLACEMENT OF THE PREVIOUS ONE RANGE OF WALL-HUNG BOILERS IN SINGLE CONFIGURATION (CODE 3.023966) 1 I models in place of the models from the previous range of This kit is composed of just two gaskets 44x34x2 (1) and two VICTRIX 50-75 wall-hung boilers in single configuration.
  • Page 19: 15 Kit Sizes And Connections (Optional) With Victrix Pro 35 1 I - 55 1 I Boilers

    3.024038. The modular boilers, i.e. installed in cascade (battery) with an Im- Immergas declines all liability whenever the installer does not use mergas original hydraulic manifold kit, must be considered a unique original Immergas devices and kits, or uses them improperly.
  • Page 20: Kit Sizes And Connections (Optional) With Victrix Pro 80 1 I Boilers In Cascade Configuration (Up To A Maximum Of Five Appliances)

    3.024038. The modular boilers, i.e. installed in cascade (battery) with an Im- Immergas declines all liability whenever the installer does not use mergas original hydraulic manifold kit, must be considered a unique original Immergas devices and kits, or uses them improperly.
  • Page 21 3.024038. The modular boilers, i.e. installed in cascade (battery) with an Im- Immergas declines all liability whenever the installer does not use mergas original hydraulic manifold kit, must be considered a unique original Immergas devices and kits, or uses them improperly.
  • Page 22: Safety Device Kit G 2 1/2" For Boilers In Cascade Configuration Victrix Pro 35 1 I - 55 1 I

    VICTRIX PRO 35 1 I - 55 1 I (CODE 3.023955) The modular boilers, i.e. appliances comprised of multiple boilers For design purposes, by installing the Immergas safety kit, the set up by the manufacturer to operate in cascade (battery) with...
  • Page 23: Safety Device Kit Dn 100 For Boilers In Cascade Configuration Victrix Pro 80 1 I - 100 1 I - 120 1 I

    VICTRIX PRO 80 1 I - 100 1 I - 120 1 I (CODE 3.023961) The modular boilers, i.e. appliances comprised of multiple boilers For design purposes, by installing the Immergas safety kit, the set up by the manufacturer to operate in cascade (battery) with...
  • Page 24: Hydraulic Separator Kit Measurements And Fittings (Optional)

    VICTRIX PRO 1 I 19 HYDRAULIC SEPARATOR KIT MEASUREMENTS AND FITTINGS (OPTIONAL) The hydraulic separator (compensator) is a particularly signif- It is advisable to include a hydraulic compensator (1) every time icant part inside the hydraulic circuits. the overall flow rate required by the system is greater than what It is an open manifold (1) which places system flow and return the boiler is able to supply.
  • Page 25 VICTRIX PRO 1 I 19.1 HYDRAULIC SEPARATOR KIT FOR BOILERS UP TO 100 KW WITH THREADED CONNECTIONS G 2 1/2" (CODE 3.020839) KEY: - Vent valve - Shut-off valve - Probe fitting (not supplied) - Hydraulic separator (12 litre capac- ity) - Draining valve 19.2 HYDRAULIC SEPARATOR KIT FOR BOILERS IN CASCADE CONFIGURATION...
  • Page 26 VICTRIX PRO 1 I 19.3 HYDRAULIC SEPARATOR KIT FOR BOILERS IN CASCADE CONFIGURATION UP TO 350 KW FLANGED CONNECTIONS DN 100 (CODE 3.023965) KEY: - Vent valve - Shut-off valve - Probe fitting (not supplied) - Hydraulic separator (42 litre capac- ity) - Draining valve 19.4 HYDRAULIC SEPARATOR KIT FOR BOILERS IN CASCADE CONFIGURATION...
  • Page 27 VICTRIX PRO 1 I 19.5 HYDRAULIC SEPARATOR KIT FOR BOILERS IN CASCADE CONFIGURATION UP TO 600 KW FLANGED CONNECTIONS DN 100 (CODE 3.023962) KEY: - Vent valve - Shut-off valve - Probe fitting (not supplied) - Hydraulic separator (85 litre capacity) - Draining valve...
  • Page 28: 20 "Free Standing" Supporting Frame Kit (Code 3.024246) For Victrix Pro 1 I

    VICTRIX PRO 1 I 20 "FREE STANDING" SUPPORTING FRAME KIT (CODE 3.024246) FOR VICTRIX PRO 1 I VICTRIX PRO 1 I can also be installed on a specific modular on the number of boilers that need to be installed. The frame supporting frame which offers single or cascade installation has supporting collars for the hydraulic manifolds and can be (up to 5 boilers), in linear set-up, or back-to-back for more...
  • Page 29: Kit Sizes And Connections (Optional) With Victrix Pro 35 1 I - 55 1 I Boilers With

    VICTRIX PRO 35 1 I - 55 1 I KIT SIZES AND CONNECTIONS (OPTIONAL) WITH VICTRIX PRO 35 1 I - 55 1 I BOILERS WITH INSTALLATION ON SUPPORTING FRAME SET UP IN LINE (UP TO A MAXIMUM OF FIVE APPLIANCES)
  • Page 30 21.1 KIT SIZES AND CONNECTIONS (OPTIONAL) WITH VICTRIX PRO 35 1 I - 55 1 I BOILERS WITH INSTALLATION ON SUPPORTING FRAME SET UP BACK-TO-BACK (UP TO A MAXIMUM OF FIVE APPLIANCES)
  • Page 31: Kit Sizes And Connections (Optional) With Victrix Pro 80 1 I - 100 1 I - 120 1 I Boilers With

    VICTRIX PRO 80 1 I -100 1 I - 120 1 I 22 KIT SIZES AND CONNECTIONS (OPTIONAL) WITH VICTRIX PRO 80 1 I - 100 1 I - 120 1 I BOILERS WITH INSTALLATION ON SUPPORTING FRAME SET UP IN LINE (UP TO A MAXIMUM OF FIVE APPLIANCES)
  • Page 32 VICTRIX PRO 80 1 I -100 1 I - 120 1 I 22.1KIT SIZES AND CONNECTIONS (OPTIONAL) WITH VICTRIX PRO 80 1 I - 100 1 I AND 120 1 I BOILERS WITH INSTALLATION ON SUPPORTING FRAME SET UP BACK-TO-BACK (UP TO A MAXIMUM OF FIVE APPLIANCES)
  • Page 33: Graph Of Victrix Pro 35 1 I - 55 1 I Pump Head Flow Rate

    VICTRIX PRO 35 1 I - 55 1 I GRAPH OF VICTRIX PRO 35 1 I - 55 1 I PUMP HEAD FLOW RATE The VICTRIX PRO 35 1 I - 55 1 I boilers are supplied with a at maximum speed. built-in circulation pump with 3-position electric speed control.
  • Page 34: Graph Of Victrix Pro 80 1 I Pump Head Flow Rate

    VICTRIX PRO 80 1 I -100 1 I - 120 1 I GRAPH OF VICTRIX PRO 80 1 I PUMP HEAD FLOW RATE The VICTRIX PRO 80 1 I boilers are supplied with a built-in (single pipe and module) it is recommended to use the pump circulation pump with 3-position electric speed control.
  • Page 35: Graph Of Victrix Pro 100 1 I Pump Head Flow Rate

    VICTRIX PRO 80 1 I -100 1 I - 120 1 I GRAPH OF VICTRIX PRO 100 1 I PUMP HEAD FLOW RATE The VICTRIX PRO 100 1 I boilers are supplied with a built-in (single pipe and module) it is recommended to use the pump circulation pump with 3-position electric speed control.
  • Page 36: Graph Of Victrix Pro 120 1 I Pump Head Flow Rate

    VICTRIX PRO 80 1 I -100 1 I - 120 1 I GRAPH OF VICTRIX PRO 120 1 I PUMP HEAD FLOW RATE The VICTRIX PRO 120 1 I boilers are supplied with a built-in (single pipe and module) it is recommended to use the pump circulation pump with 3-position electric speed control.
  • Page 37: Feed Water Treatment

    VICTRIX PRO 1 I FEED WATER TREATMENT Treating the supply water allows you to prevent problems and - for all systems, it is necessary to provide chemical condition- maintain the functionality and efficiency of the generator ing. For systems of > 350 kW it is necessary to install a safety over time.
  • Page 38: Victrix Pro 35 1 I And 55 1 I Wiring Diagram

    VICTRIX PRO 35 1 I AND 55 1 I WIRING DIAGRAM...
  • Page 39: Victrix Pro 80 1 I - 100 1 I And 120 1 I Wiring Diagram

    VICTRIX PRO 80 1 I -100 1 I - 120 1 I VICTRIX PRO 80 1 I - 100 1 I AND 120 1 I WIRING DIAGRAM...
  • Page 40: Example Of Direct Control Without Cascade Regulator Kit Of A Booster Pump And

    VICTRIX PRO 1 I EXAMPLE OF DIRECT CONTROL WITHOUT CASCADE REGULATOR KIT INAIL OF A BOOSTER PUMP AND A COMMON FLOW PROBE FUNCTION AVAILABLE FOR THE 2ND SEMESTER OF 2014 System flow probe for boiler code 3.024245 INAIL Electrical connection diagram for probes and pumps External Relay (Optional) KEY:...
  • Page 41: Example Of Simple Cascade, Without Including The Cascade Regulator (2 Boiler Max.)

    VICTRIX PRO 1 I 31 EXAMPLE OF SIMPLE CASCADE, WITHOUT INCLUDING THE CASCADE REGULATOR (2 BOILER MAXIMUM) FUNCTION AVAILABLE FOR THE 2ND SEMESTER OF 2014 BUS connection for operation in simple cascade INAIL This application can only be used in combination with a maximum of 2 boilers with the same output (in fact, while the cascade regulator - through fan rpm detection - rises and acts on the output delivered by the boilers, with simple cascade it is...
  • Page 42: Victrix Pro 35 1 I - 55 1 I Hydraulic Diagram

    VICTRIX PRO 35 1 I - 55 1 I HYDRAULIC DIAGRAM KEY: 15 - Thermofuse - Draining funnel on view 16 - Air sample point - 4 bar safety valve 17 - Flue sample point - Boiler draining valve 18 - Fumes hood - Flow manifold 19 - Venturi positive sign (P2) - Condensate trap siphon...
  • Page 43: Victrix Pro 80 1 I - 100 1 I And 120 1 I Hydraulic Diagram

    VICTRIX PRO 80 1 I -100 1 I - 120 1 I VICTRIX PRO 80 1 I - 100 1 I AND 120 1 I HYDRAULIC DIAGRAM KEY: 14 - Air sample point - Draining funnel on view 15 - Flue sample point - 4 bar safety valve 16 - Condensing module air vent valve - Boiler draining valve...
  • Page 44: Type Of Green Range Flue Installation

    80/125 kits can be used. Installed in cascade configuration inside the heating control For correct installation of the boiler, the particular Immergas units or technical rooms, it is possible to use the relevant pro- "Green" range air intake/fumes exhaust kits must be used as...
  • Page 45: 80/125 Ø Concentric Horizontal Kit

    VICTRIX PRO 1 I Ø 80/125 CONCENTRIC HORIZONTAL KIT (CODE 3.015242) THE KIT INCLUDES: 1 - N° 1 Adapter Ø 80/125 2 - N° 1 Gasket Detail (3) is as per standard with the boiler 4 - N° 1 Ø 80/125 87° concentric bend 5 - N°...
  • Page 46: 80/125 Ø Concentric Vertical Kit

    VICTRIX PRO 1 I Ø 80/125 CONCENTRIC VERTICAL KIT (CODE 3.015243) Ø 80/125 VERTICAL KIT MAXIMUM LENGTH ACCEPT- Vertical metres (including terminal) VICTRIX PRO 35 1 I = 11.5 m VICTRIX PRO 55 1 I = 18 m VICTRIX PRO 80 1 I = 15 m VICTRIX PRO 100 1 I = 11 m VICTRIX PRO 120 1 I = 6 m THE KIT INCLUDES:...
  • Page 47: Vertical Kit For Direct Exhaust

    VICTRIX PRO 1 I Ø 80 VERTICAL KIT FOR DIRECT 37.1 Ø 80 STAINLESS STEEL VERTICAL KIT EXHAUST (CODE 3.015256) FOR OUTDOOR APPLICATION (CODE 3.024295) THE KIT INCLUDES: THE KIT INCLUDES: 1 - N° 1 Wall sealing plate 1 - N° 1 Ø 80 Exhaust terminal 2 - N°...
  • Page 48: Horizontal Terminal Kit For Wall Flue Exhaust

    VICTRIX PRO 1 I Ø 80 HORIZONTAL TERMINAL KIT 38.1 Ø 80 HORIZONTAL TERMINAL KIT FOR WALL FLUE EXHAUST (CODE 3.015255) FOR FLUE EXHAUST (CODE 3.015254) THE KIT INCLUDES: THE KIT INCLUDES: 1 - N° 1 Ø 80 90° bend 1 - N°...
  • Page 49: Flue Exhaust Manifold Kit 160 Ø With Flue Adjusting Devices Victrix Pro 35 1 I - 55 1 I

    VICTRIX PRO 35 1 I - 55 1 I FLUE EXHAUST MANIFOLD KIT Ø 160 WITH FLUE ADJUSTING DEVICES VICTRIX PRO 35 1 I - 55 1 I (CODE 3.024279) THE KIT INCLUDES: 1 - Connection for 1st Boiler 2 - Connection for 2nd Boiler 3 - Clapet DN80 4 - Manifold for 1st Boiler DN160 5 - Manifold for 2nd Boiler DN160...
  • Page 50: Flue Exhaust Manifold Kit 200 Ø With Flue Adjusting Devices Victrix Pro 80 1 I - 100 1 I - 120 1 I

    VICTRIX PRO 80 1 I -100 1 I - 120 1 I FLUE EXHAUST MANIFOLD KIT Ø 200 WITH FLUE ADJUSTING DEVICES VICTRIX PRO 80 1 I - 100 1 I - 120 1 I (CODE 3.024281) THE KIT INCLUDES: 1 - Connection for 1st Boiler 2 - Connection for 2nd Boiler 3 - Clapet DN125...
  • Page 51: Th Victrix Pro 100 1 I - 120 1 I

    VICTRIX PRO 80 1 I -100 1 I - 120 1 I FLUE EXHAUST MANIFOLD KIT Ø 250 WITH FLUE ADJUSTING DEVICES FOR EXPANSION OF 4 VICTRIX PRO 100 1 I - 120 1 I (CODE 3.024666) THE KIT INCLUDES: 3 - Clapet DN125 7 - Drain trap unit 9 - Manifold for 4th Boiler DN250...
  • Page 52: Flexible Ducting System

    VICTRIX PRO 1 I Ø 80 FLEXIBLE DUCTING SYSTEM The Immergas Ø 80 mm system for flexible ducting of existing chimneys is made up from a series of components, identified as individual kits, which can be assembled depending on the specific installation requirements.
  • Page 53: Technical Data

    VICTRIX PRO 35 1 I - 55 1 I TECHNICAL DATA VICTRIX PRO 35 VICTRIX PRO 55 Maximum nominal heat input kW (kcal/h) 34.9 (30,051) 51.3 (44,098) Maximum nominal effective output (80/60°C) kW (kcal/h) 34.0 (29,240) 49.9 (42,914) Maximum nominal effective output (50/30°C) kW (kcal/h) 37.3 (32,155) 54.8 (47,097)
  • Page 54 VICTRIX PRO 80 1 I -100 1 I - 120 1 I 43.1 TECHNICAL DATA VICTRIX PRO 80 VICTRIX PRO 100 Maximum nominal heat input kW (kcal/h) 75.3 (64,722) 92.3 (79,385) Maximum nominal effective output (80/60°C) kW (kcal/h) 73.0 (62,780) 90.0 (77,400) Maximum nominal effective output (50/30°C) kW (kcal/h)
  • Page 55 VICTRIX PRO 80 1 I -100 1 I - 120 1 I 43.2 TECHNICAL DATA VICTRIX PRO 120 Maximum nominal heat input kW (kcal/h) 114.1 (98.109) Maximum nominal effective output (80/60°C) kW (kcal/h) 111.0 (95.460) Maximum nominal effective output (50/30°C) kW (kcal/h) 121.7 (104.682) Minimum nominal heat input...
  • Page 56: Combustion Characteristics For Victrix Pro 35 1 I

    COMBUSTION CHARACTERISTICS FOR VICTRIX PRO 35 1 I Methane (G20) LPG (G31) Combustion efficiency 100% Pn (80/60°C) 98.4 98.4 Combustion efficiency P min (80/60°C) 98.4 98.4 Effective efficiency at 100% Pn (80/60°C) 97.3 97.3 Effective efficiency P min (80/60°C) 86.3 86.3 Effective efficiency at 100% Pn (50/30°C) 107.0...
  • Page 57 VICTRIX PRO 35 1 I - 55 1 I 44.1 COMBUSTION CHARACTERISTICS FOR VICTRIX PRO 55 1 I Methane (G20) LPG (G31) Combustion efficiency 100% Pn (80/60°C) 98.2 98.2 Combustion efficiency P min (80/60°C) 98.3 98.3 Effective efficiency at 100% Pn (80/60°C) 97.3 97.3 Effective efficiency P min (80/60°C)
  • Page 58 VICTRIX PRO 80 1 I -100 1 I - 120 1 I 44.2 COMBUSTION CHARACTERISTICS FOR VICTRIX PRO 80 1 I Methane (G20) LPG (G31) Combustion efficiency 100% Pn (80/60°C) 97.8 97.8 Combustion efficiency P min (80/60°C) 98.6 98.6 Effective efficiency at 100% Pn (80/60°C) 97.0 97.0 Effective efficiency P min (80/60°C)
  • Page 59 VICTRIX PRO 80 1 I -100 1 I - 120 1 I 44.3 COMBUSTION CHARACTERISTICS FOR VICTRIX PRO 100 1 I Methane (G20) LPG (G31) Combustion efficiency 100% Pn (80/60°C) 98.1 98.1 Combustion efficiency P min (80/60°C) 98.5 98.5 Effective efficiency at 100% Pn (80/60°C) 97.5 97.5 Effective efficiency P min (80/60°C)
  • Page 60 VICTRIX PRO 80 1 I -100 1 I - 120 1 I 44.4 COMBUSTION CHARACTERISTICS FOR VICTRIX PRO 120 1 I Methane (G20) LPG (G31) Combustion efficiency 100% Pn (80/60°C) 98.0 98.0 Combustion efficiency P min (80/60°C) 98.4 98.4 Effective efficiency at 100% Pn (80/60°C) 97.3 97.3 Effective efficiency P min (80/60°C)
  • Page 61: Optional

    VICTRIX PRO 1 I OPTIONAL Hydraulic type of kit Safety devices kit for individual boiler IPX4D protection box kit safety devices kit code 3.023949 for individual boiler code 3.024028 Safety devices kit G 2 1/2" for Safety devices kit DN 100 for VICTRIX PRO 80 1 I VICTRIX PRO 35 1 I-55 1 I in cascade configuration 100 1 I-120 1 I in cascade configuration code 3.023955...
  • Page 62 VICTRIX PRO 1 I Kit for heat adjustment Cascade and zone regulator kit Support kit for fixing the regulator to the wall code 3.015244 code 3.015265 Zone manager kit Modulating room thermostat kit code 3.015264 code 3.015245 External probe kit External probe kit for connection to the boiler for connection to the cascade and zone regulator...
  • Page 64: Heat Adjustment Systems (Optional)

    VICTRIX PRO 1 I HEAT ADJUSTMENT APPENDIX HEAT ADJUSTMENT SYSTEMS (OPTIONAL) System heating. relevant kits, available in the 200, 300, 500, 1000, 1500 and 2000 litre versions. The Storage Tank units are equipped with double Individual modular boilers or installed in cascade configuration, require a suitable heat adjustment system able to communicate coil for heat exchange.
  • Page 65: Cascade And Zone Regulator

    VICTRIX PRO 1 I CASCADE AND ZONE REGULATOR (CODE 3.015244) The cascade and zones regulator allows to manage, control and program the functioning sequence of the connected boilers. It can be cascade and programmed via parameters that allow to guarantee ideal temperature conditions at all times of the day and night for each individual day of the week, both for the C.H.
  • Page 66: Cascade And Zone Regulator Diagram Of Connections And Terminals

    VICTRIX PRO 1 I CASCADE AND ZONE REGULATOR DIAGRAM OF CONNECTIONS AND TERMINALS There are terminal blocks on the back of the cascade and zone Some parts belonging to the heating control unit must be con- regulator dedicated to the network connections and the low nected to the respective terminal blocks.
  • Page 67: Cascade And Zone Regulator/Zone Manager Push Button Panel And Display And Control Screen

    VICTRIX PRO 1 I CASCADE AND ZONE REGULATOR / ZONE MANAGER PUSH BUTTON PANEL AND DISPLAY AND CONTROL SCREEN VICTRIX PRO 1 I zone manager VICTRIX PRO 1 I cascade and zone regulator KEY: 1 - Selection and confirmation knob 2 - Required daytime room temperature 3 - Required night-time room temperature 4 - Required D.H.W.
  • Page 68: Zone Manager

    VICTRIX PRO 1 I ZONE MANAGER (CODE 3.015264) In addition to the functions described for the cascade heat adjuster, the cascade regulator allows to control all the im- portant information regarding operation of the appliance and the heating system with the opportunity of easily intervening on the previously set parameters without having to go to the place where the cascade regulator is installed.
  • Page 69: Modulating Room Thermostat

    VICTRIX PRO 1 I MODULATING ROOM THERMOSTAT (CODE 3.015245) The modulating room thermostats (not traditional On/Off) functions only when coupled wit the cascade regulator and allows regulation of the room temperature of one of the zones into which the plant is divided (both in individual and cascade installation).
  • Page 70: External Probe To Connect To The Boiler

    VICTRIX PRO 1 I EXTERNAL PROBE TO CONNECT TO THE BOILER (CODE 3.015266) The external probe allows to decrease or increase the max. flow temperature to the system when the external temperature in- creases or decreases, in order to adjust the heat supplied to the system according to the change in external temperature.
  • Page 71: Kit For Remote Management

    VICTRIX PRO 1 I KIT FOR REMOTE MANAGEMENT (CODE 3.024244) (EXCLUSIVELY IN COMBINATION WITH THE CASCADE AND ZONE REGULATOR) Using the remote management kit it is possible to control the single boiler or cascade of boilers remotely. The remote man- agement kit only works in combination with Cascade and zone regulator code 3.015244, which requires software version 3.0 or later (the software version of the cascade and zone regulator...
  • Page 72 VICTRIX PRO 1 I 1 Registration screen. Enter the username in the upper field and the password in the lower field. N.B.: with direct connections (i.e. Ethernet, and NOT through the Internet) the pre-defined username and password that need to be entered in the window are: - Username: “EBV”...
  • Page 73 VICTRIX PRO 1 I 4 Setting central heating parameters. The window to cascade these parameters automatically opens when you click on a variable/editable parameter. The parameters can be edited by clicking on the symbols “+” or “-”. Click on “Prog” to store the set value. Press “Esc” to exit the setting mode and close the window.
  • Page 74: Examples Of Hydraulic Application Diagrams

    Each system needs to be accurately sized by a professional; Immergas will not be held liable for the failure to have a certified engineer inspect the project, who is also required to practice with good technique and in accordance with regulations in force.
  • Page 75 VICTRIX PRO 1 I 54.1 EXAMPLE SYSTEM WITH VICTRIX PRO 1 I IN SINGLE CONFIGURATION...
  • Page 76 VICTRIX PRO 1 I 54.2 EXAMPLE OF PLANT ENGINEERING FOR VICTRIX PRO IN CASCADE CONFIGURATION...
  • Page 77 VICTRIX PRO 1 I 54.3 EXAMPLE OF PLANT ENGINEERING FOR VICTRIX PRO IN CASCADE CONFIGURATION...
  • Page 79 During the useful life of the products, performance is affected by external factors, such as the hardness of the D.H.W., atmos- pheric agents, deposits in the system and so on. The declared data refers to new products that are correctly installed and used in accordance with applicable regulations. N.B.: correct periodic maintenance is highly recommended.
  • Page 80 Follow us on Immergas Italia immergas.com To request further specific details, sector Professionals can also use the following e-mail address: consulenza@ immergas.com Immergas S.p.A. 42041 Brescello (RE) - Italy Tel. 0522.689011 Fax 0522.680617 QUALITY SYSTEM CERTIFIED UNI EN ISO 9001:2008...

Table of Contents