Technical data

10.3 Electrical specifications

Pneumatic data
2 bar (29 psi)
4 bar (58 psi)
6 bar (87 psi)
Outlet air valve (depressurize actuator)
2 bar (29 psi)
4 bar (58 psi)
6 bar (87 psi)
Auxiliary power consumption in the controlled status
Device versions
10.3
Electrical specifications
Electrical data
Setpoint input I
w
2-wire connection (terminals 6/7)
Rated signal range
Current to maintain the auxiliary power
supply
Required load voltage U
resistance at 20 mA)
Without HART (6DR630*) max.
With HART (6DR631*)
Static destruction limit
For connecting to circuits with the
following peak values
156
Basic device without explosion
protection
(load
B
≤ 6.5 V (325 Ω)
≤ 7.5 V (375 Ω)
+30 V (internal current limiting approx.
+50 mA)
-150 mA (with reversed polarity
connection)
-
7,5 m³
/h (33 USgpm)
n
10,6 m³
/h (46.7 USgpm)
n
13 m³
/h (57.24 USgpm)
n
14,4 m³
/h (63.4 USgpm)
n
20,4 m³
/h (89.8 USgpm)
n
25 m³
/h (110.1 USgpm)
n
< 9,5⋅10
/h (0.26 USgpm)
-2
n
Single-acting
Basic device with explosion protection
Ex "ia", "ic", "nA", "tb"
4 ... 20 mA
≥ 3.8 mA
≤ 7.5 V (375 Ω)
≤ 8.5 V (425 Ω)
-
-
"ia"/"ic":
U
= 30 V
i
Ii = 100 mA
Pi = 1 W
Ci = 33 nF
Li = 0,19 mH
"nA"/"tb"
U
= 30 V
n
In = 100 mA
Operating Instructions, 03/2011, A5E01258666-03