Download Print this page
Elkay EZSTL8S2JOC Installation & Use Manual
Elkay EZSTL8S2JOC Installation & Use Manual

Elkay EZSTL8S2JOC Installation & Use Manual

Advertisement

Quick Links

Configuration as Shipped
Description
Combination Refrigerated Drinking Fountain (Cooler) delivers chilled, clean potable drinking water. Two-level water cooler houses the refrigeration
and delivers a steady stream of water for direct drinking at the press of the front and sidebars.
Ratings
• Electrical: 230Vac, 50Hz, (See Nameplate for Amperage), 1 phase.
• Ambient Air Temperature: 50-100.4 °F (10-38 °C).
• Water Pressure: 20-100 psig (0.14-0.69 MPa).
• Maximum Water Temperature: 90 °F (32 °C).
• Refrigerant: HFC-R134a
Definitions
DANGER
– Indicates death or serious injury will result if proper precautions are not taken.
WARNING
– Indicates death, serious injury or property damage can result if proper precautions are not taken.
CAUTION
– Indicates some injury or property damage may result if proper precautions are not taken.
Authorized Service Personnel – Factory trained personnel or personnel having working knowledge of electrical,
plumbing and machine (appliance) maintenance procedures.
Safety
DANGER
• Please read these instructions completely before starting the installation or performing any service. Failure to follow the instructions and safety
precautions in this manual can result in serious injury or death.
• After installation, keep these instructions in a safe location for future reference.
• Electric supply must be identical in voltage, cycle, and phase to that specified on nameplate.
• Electrical supply must have Ground Fault Circuit Interrupter (GFCI) protection.
• A means for disconnecting electrical supply to the unit must be incorporated in the fixed wiring in accordance with wiring rules. This is to allow
electrical disconnection of the unit from electrical supply after installation.
WARNING
• For use with clean, clear potable drinking water only. Do not use with water that is microbiologically unsafe or of unknown quality without adequate
disinfection before the system.
• Installation and connection to water and electrical mains must be in compliance with local and national laws.
• All Installation and Service work must be performed by an authorized service personnel.
CAUTION
• This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory, or mental capabilities or lack of
experience and knowledge if they have been given supervision or instructions concerning use of the appliance in a safe way and understand the
hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
• To prevent a metallic taste or increased metal content in the water due to an electrolysis process caused by electrical feedback from the grounding
of electrical equipment to water supply and water waste mains, connect to these mains using non-conductive materials. The provided solenoid
valve regulator assembly meets this requirement.
EZFSTL8_2H
Installation & Use Manual
Original Instructions
Model: EZSTL8S2JOC
• Ingress Protection: IP21
• For Indoor Commercial Use only.
• Water Inlet: 3/8"O.D. unplated copper tube.
• Waste Water Outlet: 1-1/2" (38.1mm) O.D. tube
Page 1
Alternate Mounting Configuration
1000003507 (Rev. B - 01/19)

Advertisement

loading

Summary of Contents for Elkay EZSTL8S2JOC

  • Page 1 EZFSTL8_2H Installation & Use Manual Original Instructions Model: EZSTL8S2JOC Alternate Mounting Configuration Configuration as Shipped Description Combination Refrigerated Drinking Fountain (Cooler) delivers chilled, clean potable drinking water. Two-level water cooler houses the refrigeration and delivers a steady stream of water for direct drinking at the press of the front and sidebars.
  • Page 2: Installation: Electrical Connection

    EZFSTL8_2H Installation For correct and safe installation, please read these instructions completely. DANGER • All Installation work must be performed by an authorized service personnel. • Disconnect electrical supply serving the Installation area to reduce risk of electrocution. • Unit not suitable for installations where water jets could be used. WARNING •...
  • Page 3 EZFSTL8_2H Rough-In: EZSTL8S2JOC Standard Mounting 18 3/8" 19" 467mm 483mm 18 3/8" 467mm 6 3/8" 6 3/8" 6 3/8" 6 3/8" HANGER 162mm 162mm 162mm 162mm BRACKET 9/32" 7mm DIA. ((12) ‰ ‰ 2" 51mm 2" 2" 51mm 51mm 38 3/8"...
  • Page 4: Operation: Start-Up

    EZFSTL8_2H Operation: Start-Up 1. Turn on the building water supply and check all connections for leaks. 2. Rotate fan to insure proper clearance and free fan action. 3. Connect plug-end of International Power Cord Set (sold separately) into electrical outlet. WARNING •...
  • Page 5 EZFSTL8_2H Service: Inspection/Replacement • Inspect Cooler twice each year for proper operation and performance. • Inspection of the unit will require disconnecting electrical supply, removal of panels, etc. and reassembly and return to service practices. 1. Lower Front Panel and Upper Shroud: To access the refrigeration system and plumbing connections, remove four (4) screws from bottom of cooler to remove the lower front shroud.
  • Page 6: Regulator Assembly

    REGULATOR ASSEMBLY ALIGNMENT NOTCH SNAP SNAP ALIGNMENT For Replacement Parts, contact your local distributor or call 1.800.834.4816 Elkay Manufacturing Co. 2222 Camden Court – Oak Brook, IL 60523 U.S.A – 630.574.8484 – www.elkay.com 1000003507 (Rev. B - 01/19) Page 6...