Table of contents
11.2.4.17
Diagnostic value '18.ZERO - Lower endstop'.......................................................................220
11.2.4.18
Diagnostic value '19.OPEN - Upper endstop' ......................................................................221
11.2.4.19
Diagnostic value '20.PAVG - Average value of position'......................................................221
11.2.4.20
Potentiometer value of upper endstop (100%)' ....................................................................221
11.2.4.21
11.2.4.22
Diagnostic value '25.PAUTP - Pulse interval'.......................................................................223
11.2.4.23
11.2.4.24
11.2.4.25
Diagnostic value '30.TEMP - Current temperature'..............................................................224
11.2.4.26
11.2.4.27
Diagnostic value '33.T1' ... '41.T9' - Number of operating hours in the temperature range
1 to 9 ....................................................................................................................................225
11.2.4.28
Diagnostic value '42.VENT1' / '43.VENT2' ..........................................................................225
11.2.4.29
Diagnostic value '44.VEN1R' / '45.VEN2R' ..........................................................................225
11.2.4.30
Diagnostic value '46.STORE - Save maintenance data' ......................................................226
11.2.4.31
11.2.4.32
Diagnostic value '49.WT00' ... '56.WT95' - Number of operating hours in the travel range
WT00 to WT95 .....................................................................................................................227
11.2.4.33
11.2.4.34
11.2.4.35
Diagnostic value '59.mA - Setpoint current' .........................................................................228
11.2.4.36
Diagnostic value '60.PZ Supply pressure (PZ)'....................................................................228
11.2.4.37
11.2.4.38
Diagnostic value '64.N_MIN Event counter' .........................................................................228
11.3
Online diagnostics................................................................................................................229
11.3.1
Overview of error codes .......................................................................................................229
11.3.2
Overview of online diagnostics.............................................................................................231
11.3.3
XDIAG parameter ................................................................................................................231
11.3.4
Meaning of error codes ........................................................................................................232
11.3.4.1
1 Remaining control deviation..............................................................................................232
11.3.4.2
2 Device not in "Automatic" mode ........................................................................................232
11.3.4.3
3 digital inputs BIN1 or BIN2 active......................................................................................232
11.3.4.4
4 Monitoring the number of total strokes..............................................................................232
11.3.4.5
5 Monitoring the number of changes in direction .................................................................232
11.3.4.6
6 Monitoring the lower endstop / 7 Monitoring the upper endstop .......................................232
11.3.4.7
8 Monitoring deadband ........................................................................................................233
11.3.4.8
9 Partial stroke test ..............................................................................................................233
11.3.4.9
10 Monitoring of dynamic control valve behavior .................................................................233
11.3.4.10
11 Monitoring/compensation of pneumatic leakage ............................................................234
11.3.4.11
12 Monitoring of stiction (slipstick) .......................................................................................234
11.3.4.12
13 Monitoring the lower limit temperature ............................................................................234
11.3.4.13
14 Monitoring the upper limit temperature ...........................................................................234
11.3.4.14
15 Monitoring the position average value ............................................................................234
11.3.4.15
11.3.4.16
17 Monitoring of pressure sensor module............................................................................234
11.3.4.17
18 Monitoring low limit of supply pressure (PZLIM) .............................................................234
11.3.4.18
19 Monitoring specific limits of supply pressure...................................................................234
11.4
Fault and remedy .................................................................................................................235
8
SIPART PS2 with 4 to 20 mA/HART
Operating Instructions, 11/2019, A5E00074631-AE