CAUTIONS KEEP HANDS AWAY FROM MECHANICAL DRIVE COMPONENTS WHEN THE COPIER IS WARM- ING UP. This is to avoid possible injury when the copier starts idling at the end of warm up. ALWAYS REINSTALL THE FUSING UNIT COVER AFTER SERVICING. This is to prevent the operator from accidentally touching the hot unit, or the fusing lamp terminal.
Page 2
RICOH RICOH FT3020/FT3050/FT3060 F I E L D S E R V I C E M A N U A L RICOH COMPANY, LTD.
Environment Temperature Range : 10°C to 30°C (50°F to 86°F) 15% to 90% RH Humidity Range Ambient Illumination : Less than 1,500 Iuxs (Do not expose to direct sunlight) Ventilation Room air should turn over at least 3 times/hour. Less than 0.15 mg/m Ambient Dust (4 x 100¯³...
1B. Machine Level 1. Front to Back: Within 5mm (0.2”) of level 2. Right to Left: Within 5 mm (0.2”) of level (Legs may be screwed up or down to level the machine. Set a carpenter’s level on the exposure glass.)
July 1, ’85 1C. Minimum Space Requirements 1Ocm (4”) 1. Front : 7 0 c m ( 2 7 - 1 / 2 ” ) 2. Back : (4“) 3. Right : 7 0 c m ( 2 7 - 1 / 2 ” ) Left 7 0 c m ( 2 7 - 1 / 2 ”...
1 D. Power Source Input Voltage Level 110V/60Hz : More than 12A 115V/60Hz : More than 12A 2 2 0 V / 5 0 H z : More than 7A 2 4 0 V / 5 0 H z : More than 7A Permissible Voltage Fluctuation : ±...
Page 12
2A. Unpacking Procedure 1. Remove the 4 box joiners and the top box. (See illustrations) 2. Take out the accessories. 3. Remove the cushion blocks. 4. Open the vinyl bag. 5. Take out the machine. Joiners Pull out the outer portion of the Box Jointer and take off the Top Squeeze and pull out the inner portion of the Box Joiner.
Page 13
July 1, ’85 6. Remove the six strips of tape shown in the illustrations to the right.
Page 14
9. Remove the left cover (3 screws). 10. Remove the scanner lock plate (2 screws [FT3020]/1 screw [FT3050/ FT3060]). N O T E : Do not throw away the scanner lock plate. It is necessary to reinstall it if the copier is transported to a new location.
Page 15
Envelope for N.E.C.R. (115V only) ....1 Multi-lingual Decal (220/240V only) ....2 large, 1 small [FT3020]...
Page 18
Installation Check the machine level (within 5 mm (0.2”)). Open the front cover and push the slide unit to the left. Open the exit assembly and fill the oil bottle with silicone oil. Remove the fusing unit cover (2 screws) and the pressure plate (2 non-tapping screws).
Page 19
Remove the charge corona unit together with the wire cleaner (1 screw). Turn the drum shaft knob CLOCKWISE and take off the drum stay. Take out the development unit and place it on a sheet of paper. Take out the cleaning unit, the erase lamp unit, and the drum flange.
Page 20
Dust the drum, the cleaning blade, the clean- ing brush, and the cleaning side seals with set- ting powder. Pour one bottle of developer (1 kg RICOH TYPE 4000) into the development unit. Turn the paddle roller knob counterclockwise to smooth the developer while pouring it in.
Page 21
14. Pull out the drum guide and insert the drum. 15. Set the drum flange. 3 - 4...
Page 22
16. Insert the development unit, the cleaning unit, and the erase lamp unit. NOTE: When the development unit and the clean- ing unit are well set, their front surfaces are flush with the drum flange. Turn the knobs of the development and cleaning units counterclockwise to engage gears.
Page 23
July 1, ’85 Open the by-pass feed table and the black inner cover. Turn down the toner cartridge holder and set a toner cartridge. Reset the toner cartridge holder, the inner cover, and the by-pass feed table. Install the original holder [FT3060]. Load paper in the cassette;...
Page 24
3B. Cassette Modification 1. Take off the cassette cover. 2. Move the side fences and the rear fence to the desired paper size position (1 screw each). NOTE: Paper size positions are shown on the bot- tom of the cassette. 3.
Page 25
8. Reassemble the copier and check key counter operation. Remove the front right cover (2 screws). Open the front cover and remove the inner cover (4 screws). [FT3020] Open the front cover, push the slide unit to the left, and remove the inner cover (5 screws). [FT3050/FT3060] Remove the cover plate and fixing plate from the key counter bracket.
Page 26
SECTION 4 PREPARATIONS FOR TRANSPORTING THE COPIER...
Page 27
Preparation for Transporting the Copier [FT3020] ........
Page 28
4A. Preparations for Transporting the Copier [FT3020] Before moving the copier from its place of installa- tion, be sure to prepare it for transportation as follows. The copier may be badly damaged if it is moved without proper preparation. Take off the left cover (3 screws) and fix the scanner in the home position with the scanner lock plate.
Page 29
Plug it Remove the toner collection bottle. with the rubber lid and transport it separately. Remove the drum and transport it separately in a drum box. Remove the developer and clean the develop- ment unit. Clean the cleaning unit. Reinsert the development unit, the cleaning unit, and the drum flange.
Page 30
July 1, ’85 4B. Preparations for Transporting the Copier [FT3050/FT3060] Before moving the copier from its place of installa- tion, be sure to prepare it for transportation as follows. The copier may be badly damaged if it is moved without proper preparation. Take off the left cover (3 screws) and fix the scanner in the home position with the scanner lock plate.
Page 31
Plug it Remove the toner collection bottle. with the rubber lid and transport it separately. Remove the drum and transport it separately in a drum box. Remove the developer and clean the develop- ment unit. Clean the cleaning unit. Reinsert the development unit, the cleaning unit, and the drum flange.
Page 33
5. REMARKS Points to Remember ..............5-1 Handling the Drum .
Page 34
July 1, ’85 5A. Points to Remember Exposure Drum Charge 1. Do not adjust the following parts: The charge corona wire should be cleaned at First and Second Scanner Height Adjust- every service call by sliding the corona unit. ing Cams If the corona wire cannot be cleaned using b.
Page 35
Oct. 1, ’83 Clean the exposure glass with glass cleaner and dry cloth. Toner Do not touch the following parts with bare Image density sensor should be cleaned at hands: every EM or PM with a blower brush. Reflectors b. Exposure Lamp Do not touch the sensor pattern with bare Mirrors and Lens hands.
Page 36
Paper Feed and Clutches 1. Grease the following parts with Mobil Temp. When a new cleaning blade, a new cleaning 78 periodically to avoid noise and bad opera- brush, and/or new cleaning side seals are tion: installed, dust them with setting powder a.
Page 37
Never set the slide unit without setting the drum stay to avoid drum damage. If a blurred or fuzzy area appears in the center of copies, it may be necessary to clean the drum. (Use RICOH Drum Cleaning Powder. Part No. 54479605) 5 - 4...
Oct. 1, ’83 6A-1. Exposure Glass Removal 1. Take off the left scale (2 short screws). 2. Loosen the two screws that tighten down the right side of the top cover. 3. Remove the exposure glass. NOTE: When installing the left scale: make sure the exposure glass is flush with the sensor pattern plate.
Oct. 1, ’83 6A-2. Exposure Lamp Replacement [FT3020] CAUTION: * To avoid warping the scanner, move it by pushing or pulling the wire clamp or drive wire only. * Do not handle the exposure lamp with your bare hands. Use a strip of paper as shown.
Page 44
Rotate the lamp terminal as shown and take out the lamp. Install a new lamp. Check the lamp position and light intensity. NOTE: * The blister on the lamp must point toward the mouth of the reflector.
Oct. 1, ’83 6A-3. Uneven Exposure Adjustment Exposure Lamp Position Remove the top cover and the exposure glass (10 screws). Verify that the lamp is properly seated. Move the scanner to the right. Open the by-pass feed table, the black inner cover, and the toner cartridge holder.
Page 46
July 1, ’85 Il. Adjusting Plates If uneven exposure still exists after the above The side to side variation * Adjustment Standard: adjustment, do the following: of the gray scales should be less than 1 level. 1. Remove the exposure glass. 2.
Oct. 1, ’83 6A-4. Scanner Drive Wire Replacement [FT3020] 1. Take off the Top cover (8 short screws) and left cover (3 screws). 2. Remove the rear cover (2 screws) and the main PCB (2 screws, 4 connectors). 3. Remove the following parts:...
Page 48
Secure one end of the new wire with the 15. Check and adjust the magnification (See 6G- anchor screw. 1 ) . Run the wire under the inside track of WP1 and then through the wire clamp to WP2. Next, set the wire in the inside track of WP2 and then run it over the inside track of WP3.
6A-5. Scanner Drive Clutch Removal [FT3020] Follow Scanner Wire Replacement (6A-4) steps 1 to 4. Slide the bearing and the scanner drive pulley (1 shoulder screw) off of the clutch shaft. Remove the scanner drive belt tightener (2 screws), and slide off the clutch drive pulley.
NOTE: * The blister on the lamp must point toward 6A-6. Exposure Lamp Replacement the mouth of the reflector. [FT3050/FT3060] CAUTION: * To avoid warping the scanner, move it by pushing or pulling the wire clamp or scanner drive pulley only. * Do not handle the exposure lamp with your bare hands.
July 1, ’85 6A-7. Scanner Drive Wire Replacement [FT3050/FT3060] Remove the platen cover and the platen cover mounting studs. Remove the top cover (8 screws). Remove the rear cover (2 screws) and the left cover (3 screws). Remove the following parts; * Inlet cooling fan (5 screws, connectors as necessary) * Exhaust fan (2 screws)
Page 52
Oct. 1, ’83 15. Reassemble the copier. Reinstall the magnification change clamp. 16. Check and adjust the magnification (See 6G- Move the second scanner to the return posi- 5) . tion. Working from the clamp, thread the long end of the wire in the lower groove of the clamp and run it under the inside track of the tension pulley (WP1).
July 1, ’85 6A-8. Lens Drive Motor Replacement [FT3050/FT3060] Remove the following parts; * Charge Corona Unit (1 screw) * Drum Stay * Development Unit * Cleaning Unit * Erase Lamp Unit * Quenching Lamp Unit * Drum Flange and Drum * Exposure Glass (4 screws) Take off the rear cover (2 screws) and the optics PCB (1 screw, 4 connectors).
Page 54
Remove the lens housing cover (3 screws). Disconnect the lens drive motor connector and disengage it from the rear side plate. Lift up the clamps holding the lens drive motor harness. R e m o v e t h e l e n s d r i v e m o t o r a s s e m b l y ( 2 screws).
July 1, ’85 6A-9. Lens Home Position Sensor Adjustment [FT3050/FT3060] NOTE: When the lens home position sensor is rep- laced or when horizontal magnification and/or a focus will not improve by adjusting the wire clamp, do this adjustment. Remove the exposure glass (4 screws), the lens housing cover (3 screws), and the rear cover (2 screws).
Page 56
Oct. 1, ’83 Open the front cover to prevent the scanner from moving and turn on the main switch. Select the DC 20V range of the digital multimeter, and connect the multimeters leads — the COM line to logic ground and the input line to CN202-9 on the optics PCB.
Page 57
6B-5. Image Density Sensor Adjustment [FT3020] ........
Repeat the above steps until you have removed all of the developer. Turn the unit rightside up and pour in one bot- tle (1 kg) of RICOH TYPE 4000 developer. 6-12...
6B-2. Doctor Gap Adjustment * Adjustment Standard: 1.25 ± 0.1 mm (0.049” ± 0.004”) Take out the development unit and empty the developer. Take off the upper cover (2 screws). Before making the adjustment, confirm that both surfaces where the thickness gauge will be inserted are clean.
6B-3. Toner Tank Removal Take out the development unit. Remove the two right covers (2 screws each). Open the by-pass feed table. Lower the inner cover. Remove the toner tank cover (2 screws). Insert a sheet of paper under the toner tank to catch falling toner.
6B-4. Image Density Sensor Replacement 1. Take out the development unit, the cleaning unit, the erase lamp unit, and the drum. 2. Remove the drum guide. 3. Remove the ID sensor PCB (1 screw, 1 con- nector). 4. Replace the ID sensor. NOTE: * Make sure the shield plate is set so that it is held firmly by the screw.
6B-5. Image Density Sensor Adjustment [FT3020] CAUTION: Before adjusting the ID sensor after n e w d r u m i n s t a l l a t i o n , c y c l e t h e...
6B-6. Toner Supply Clutch Disassembly [FT3020] Remove the rear cover (2 screws). Remove the main PCB (2 screws, 4 connec- tors). Remove the C/B power pack holder (1 screw) and the bias lead wire clamp (1 screw). Loosen the screw securing the tension pulley of development unit drive belt.
Page 64
9. Remove the toner supply clutch sleeve and spring together from the clutch hub by turning the sleeve clockwise. 10. Clean the clutch hub, pulley, and spring, and then grease the spring with Mobil Temp 78. 11. Reassemble. CAUTION: When reassembling, make sure that the chamfered end of the clutch sleeve is to the inside.
6B-7. Toner Supply Solenoid Adjustment 1. Remove the main PCB (2 screws, 4 connec- tors). [FT3020] Remove the optics PCB (1 screw, 4 connec- tors). [FT3050/FT3060] 2. Take off the paper feed drive belt tightener (1 screw). 3. Adjust the solenoid stroke to 2 ± 0.5 mm (0.08”...
Page 66
July 1, ’85 6B-8. Image Density Sensor Adjustment [FT3050/FT3060] CAUTION: Before adjusting the ID sensor after cycle new drum installation, machine about 5 times in Free Run mode to clean the setting powder from the drum. NOTE: It is better to use a plastic screw driver to avoid possible drum damage.
July 1, ’85 6B-9. Toner Supply Clutch Disassembly [FT3050/FT3060] Remove the rear cover (2 screws). Remove the optics PCB (1 screw, 4 connec- tors). Remove the C/B power pack holder (1 screw) and the bias lead wire clamp (1 screw). Loosen the screw securing the tension pulley of development unit drive belt.
Page 68
9. Remove the toner supply clutch sleeve and spring together from the clutch hub by turning the sleeve clockwise. 10. Clean the clutch hub, pulley, and spring, and then grease the spring with Mobil Temp 78. 11. Reassemble. CAUTION: When reassembling, make sure that the chamfered end of the clutch sleeve is to the inside.
Page 70
6C-1. Cleaning Blade and Brush Replacement 1. Take out the cleaning unit. 2. Remove the old blade (1 screw). 3. Remove the drum stay pin. 4. Remove the brush spindle. 6-22...
Page 71
5. Stand the unit up on the toner return pipe as shown; press the brush down against the cushion, and take it out. 6. Clean the unit. 7. Check all seals, including the inner mylar seal. Replace any that are damaged. 8.
Page 72
6C-2. Pick-off Pawl Replacement CAUTION: Be careful not to damage the edge of new pawls. Remove the pick-off plate (2 screws). Remove the snap rings from the ends of the pick-off pawl shaft. Rotate the pawls 180° and slip them off the ends of the shaft as shown.
Page 73
6C-3. Helical Coil Replacement Unhook the pressure and release springs. Take off the pressure lever (1 screw). Take off the cam gear (1 screw). Remove the coil knob (1 E-ring) and slide off the plastic pipe-cover. Pull out the helical coil. Take off the E-ring and plastic bushing, and mount them on a new helical coil.
Page 74
6D. PAPER FEED Roller Replacement 6D-1. l. Pick-up Roller and Feed Roller ........... 6-28 II.
6D-1. Roller Replacement Pick-up Roller and Feed Roller. 1. Remove the upper feed guide plate (2 screws). 2. Remove the snap ring and slide off the pick-up roller. 3. Remove the snap ring and slide off the feed roller. NOTE: The feed roller must be installed with beveled edge of the one-way bearing the left.
Separation Roller & Slip Clutch Remove the separation roller cover (2 screws). Take off the snap ring and slide the separation roller off the shaft. Slide the slip clutch off the shaft. Clean the clutch and grease it with Mobil Temp 78.
Push the slide unit to the left. Take off the rear cover (2 screws). Remove the main PCB (2 screws, 4 connec- tors). [FT3020] Remove the optics PCB (1 screw, 4 connec- tors). [FT3050/FT3060] Remove the rear spindle of the registration guide assembly (2 screws).
6D-3. Paper Lift Detector Adjustment Load about 20mm (0.8”) of paper into the cassette and set it to the copier. Turn on the main switch. Check the clearance between the pick-up roller and the paper. * If it is 2 ± 1 mm (0.08” ± 0.04”), the following steps are unnecessary.
6D-4. Paper End Detector Adjustment After adjusting the paper lift detector do this adjust- ment. Load about 20 mm (0.8”) of paper in the cassette and set it in the copier. Turn on the main switch with the by-pass feed table and the front cover closed.
Page 80
Oct. 1, ’83 Open the by-pass feed table and the inner cover. Remove the toner tank cover (2 screws). Move the adjusting plate of the paper end detector up or down by the amount that the measurement was out of standard in step 5. Close the inner cover and the by-pass feed table.
6D-5. Paper Feed Solenoid and Registration Solenoid Adjustment Paper Feed Solenoid Check that there is some clearance between the clutch pawl and the clutch sleeve when the solenoid is on. Registration Solenoid Adjust the solenoid position to make a 1 ± 0.2 mm (0.04”...
July 1, ’85 6D-6. Paper Feed Clutch Disassembly Remove the rear cover (2 screws). Remove the main PCB (2 screws, 4 connec- tors). [FT3020] Remove the optics PCB (1 screw, 4 connec- tors). [FT3050/FT3060] Loosen the belt tension pulley (1 screw).
Page 83
8. Take the clutch sleeve and spring off of the clutch hub. CAUTION: Be careful not to damage the clutch spring. 9. Clean the clutch hub, pulley, and spring. 10. Grease the clutch spring with Mobil Temp 78. 11. Reassemble. CAUTION: * When reassembling, make sure that the projections on the clutch are...
July 1, ’85 6D-7. Registration Clutch Disassembly Remove the rear cover (2 screws). Remove the main PCB (2 screws, 4 connec- tors). [FT3020] Remove the optics PCB (1 screw, 4 connec- tors). [FT3050/FT3060] Unhook the tension spring of the main drive chain.
Page 85
9. Clean the clutch parts and grease the clutch spring with Mobil Temp 78. 10. Reassemble. CAUTION: * When reassembling make sure that the projections on the clutch spring are engaged with the clutch hub and the clutch sleeve. * Also, make sure that the chamfered end of the clutch sleeve is to the inside.
Page 86
Remove the rear cover (2 screws) and the main PCB (2 screws, 4 connectors). [FT3020] Remove the rear cover (2 screws) and the o p t i c s P C B ( 1 s c r e w , 4 c o n n e c t o r s ) .
6D-9. Paper Feed Sensor Replacement CAUTION: Be careful not to damage the mylar seal. 1. Open the front cover and remove the follow- ing parts: * Charge Corona Unit * Drum Stay * Development Unit * Cleaning Unit * Erase Lamp Unit * Drum Flange and Drum 2.
Page 88
6E. TRANSPORT 6E-1. Slide Unit Removal ..............6-42 6E-2.
Page 89
6E-1. Slide Unit Removal 1. Push the slide unit to the left. 2. Take off the slide unit handle (1 screw). 3. Take the slide unit out of the machine. When reinstalling the slide unit, make CAUTION: sure the two accurides are set cor- rectly.
Page 90
6E-2. T/S Power Pack Replacement 1. Remove the slide unit (See 6E-1). 2. Take off the toner collection bottle holder (1 E-ring). 3. Unscrew the ground wire. 4. Remove the power pack from the slide unit connector, 2 high base plate (1 screw, 1 voltage lines).
Page 91
6E-3. Transport Roller Replacement Take out the slide unit (See 6E-1). Take the fusing unit off the slide unit (See 6F- Remove the toner collection bottle holder (1 E- ring). Remove the transport guide plate (2 screws). Remove the gear and bushings from the front ends of the first and second roller shafts (2 E- rings).
Page 92
..... 6-46 Fusing Unit Removal ......... 6 F - 1 .
6F-1. Fusing Unit Removal Push the slide unit to the left. Remove the connector cover (1 screw) and uncouple the three fusing unit connectors. Lower the exit assembly and the exit guide plate. Remove the fusing unit from the slide unit base plate (3 screws).
Page 94
6F-2. Cleaning Pad Replacement 1. Remove the fusing unit (See 6F-1). 2. Remove the cleaning pad (2 screws). 3. Install a new pad. NOTE: The cleaning pad is reversable. However, do not use the other side if it is too oily. 6-47...
6F-3. Oil Supply Pad Replacement 1. Remove the fusing unit cover (2 screws). 2. Remove the pressure plate (2 screws). 3. Remove the oil supply pad. 4) Install a new oil supply pad. NOTE: * Make sure that flathead side is up. * When reassembling, use non-tapping screws to secure the pressure plate.
6F-4. Oil Blade Replacement 1. Remove the oil supply pad (See 6F-3). 2. Unhook the two springs and take out the oil blade. 3. Loosen the three blade holder screws and take out the blade. 4. Insert a new oil blade under the blade holder. NOTE: The marked side of the blade should face the screw-head side.
6F-5. Hot Roller Replacement CAUTION: When replacing the hot roller, be care- ful not to damage the thermistor. Remove the fusing unit (See 6F-1). Remove the oil blade (See 6F-4). Take off the fusing unit knob and knob gear. Pull and rotate the front lamp terminal, and take out the fusing lamp.
Page 98
Remove the gears, bearings, and bushings from both ends (1 C-ring each). Slide the hot roller slightly to the rear and take it out through the exit assembly opening. Tear the protective paper from the ends of a new hot roller and install it carefully. After the hot roller is set, tear off the protec- tive paper.
6F-6. Pressure Roller Replacement Remove the fusing unit (See 6F-1). Take off the fusing unit cover (2 screws). Remove the cleaning pad (2 screws). Take off the oil tank (1 screw). Unhook the pressure springs. Remove the front pressure lever (1 E-ring). Remove the oil pan screw.
6F-7. Hot Roller Stripper Replacement 1. Pull out the fusing unit and open the exit assembly. 2. Unhook the springs and take off the hot roller strippers. 3. Snap on new strippers and connect the springs. 6-53...
6F-8. Pressure Roller Stripper Replacement CAUTION: Be careful not to bend or deform the pressure roller strippers when install- ing. 1. Pull out the fusing unit and open the exit assembly. 2. Take out the lower exit guide bracket (1 screw).
Page 102
Oct. 1, ’83 6F-9. Thermistor Replacement Remove the fusing unit (See 6F-1). Remove the oil blade (See 6F-4). Take off the oil sump (2 screws). Remove an idle gear A (1 E-ring). Unhook the thermistor spring and remove the thermistor (1 wire clamp). 6-55...
6F-10. Thermofuse Replacement Lower the exit assembly and take off the fus- ing unit cover (2 screws). Remove the wire clamp holding the lead wires of the thermofuse and the fusing lamp. Take out the two screws holding the top stay and turn it over.
6F-11. Felt Wick Replacement 1. Remove the oil supply pad (See 6F-3). 2. Remove the oil sump from the felt wick holder (2 screws). 3. Take off the old felt wick. 4. Prime a new felt wick with silicone oil and install it.
Page 105
6F-12. Checking Hot Roller Temperature * If the temperature is too low, either the thermister o r t h e f u s i n g c o n t r o l u n i t m a y b e d e f e c - Push the slide unit to the left.
Page 106
6F-13. Fusing Temperature Selection (DIP SW) Fusing Temperature and Fusing Control Unit Replacement 1. Follow Transport Roller Replacement (6E-3) steps 1 through 7. 190°C 2. Lift off the vacuum fan assembly. 185°C * Temperature Selection : 180°C With the two DIP swiches on the fusing control unit, select the desired fusing temperature accord- ing to the table on the right.
Oct. 1, ’83 6G-1. Horizontal Magnification Adjustment [FT3020] 1. Remove the rear cover (2 screws). 2. Remove the top cover (8 screws). 3. Loosen the wire clamp screws. 4. Move the lamp right to enlarge the copy image. Move it left to make the image smaller.
6G-2. Home Position Adjustment [FT3020] NOTE: * After adjusting the horizontal magnifica- tion do this adjustment. * Turn the main switch off before doing home position adjustment. Move the scanner bracket 24.5mm (0.96”) from the outside of the left optical frame.
6G-3. Leading Edge Registration Adjustment * Adjustment Standard: –2 ± 2 mm (0.08 ± 0.08”) Leading edge registration is adjusted by changing registration switch position. Delay Paper Feed Speed Up Paper Feed 6-64...
If the light intensity is not proper, do the following. Open the front cover and remove the inner cover (4 screws). [FT3020] Open the front cover, push the slide unit to the left, and remove the inner cover (5 screws).
July 1, ’85 6G-5. Horizontal Magnification Adjustment [FT3050/FT3060] Remove the rear cover (2 screws). Remove the top cover (8 screws). Loosen the wire clamp screws. Move the lamp right to enlarge the copy image. Move it left to make the image smaller.
July 1, ’85 7. By turning on/off the main switch, check the 6G-6. Home Position Adjustment [FT3050/ FT3060] distance several times. NOTE: * After adjusting the horizontal magnifica- Readjust the position of the home position tion do this adjustment. sensor bracket as necessary. * Turn the main switch off before doing home position adjustment.
July 1, ’85 6G-7. Leading Edge Registration Adjustment [FT3060] * Adjustment Standard: –2 ± 2 mm (0.08 ± 0.08”) Leading edge registration is adjusted by changing the dial setting of DGS201 on the optics PCB. Dial Settings Leading Edge Registration 1.0 mm / Step 6-66-b...
OTHERS 6H-1. Corona Wire Replacements Charge Corona Wire CAUTION: * Do not handle the new corona wire with your bare hands. Oil on the wire will cause uneven charge on the drum. Do not rub the corona wires with rough material (sandpaper etc.) because the corona wires are car- bon coated.
Page 117
5. Hook the large eyelet of the new corona wire to the front anchor post. 6. Hook the tension spring to the small eyelet and then hook it to the rear terminal. 7. Reassemble the charge corona unit. NOTE: Make sure that the corona wire is posi- tioned between the cleaner pads.
T/S Corona Wires Remove the front and rear endblock covers (1 screw each). Unhook the spring from the front endblock terminal and take off the old corona wire. Insert one eyelet of the new corona wire through the hole of the rear endblock and hook it to the terminal spring.
( T h e i l l u s t r a t i o n f o r F T 3 0 5 0 / F T 3 0 6 0 i shown on the next page.) C A U T I O N : All the DIP SW’s on the switching [FT3020] board should be off. 6-71...
Page 120
July 1, ’85 Remove the following parts (Front Side): * Toner Collection Bottle * Charge Corona Unit * Drum Stay * Development Unit * Cleaning Unit * Erase Lamp Unit * Drum Flange, Drum, and Drum Guide Slide the drum shoe with the shoe adapter on the drum shaft.
[Charge Corona] Slide the drum shoe to the middle of the drum shaft. Position the drum shoe so that the current sensing plate faces up vertically. Select the DC µA range of the digital multimeter. Turn on DIP SW #3 on the switching board. Turn off the charge compensation switch on the C/B power pack (See next page).
Page 122
7. Adjust the charge corona current by turning the VR on the C/B power pack. NOTE: Wait 20 seconds for the current to stabil- ize. 8. Turn off the main switch and DIP SW #3. 9. Turn on the charge compensation switch. [FT3050/FT3060] [FT3020] 6-74...
Oct. 1, ’83 [Transfer and Separation Coronas] * Adjustment Standards: Transfer Corona; DC +15.2 ± 0.6µA Separation Corona; AC 25.1 ± 1.5µA DC -0.6 +0.25 µA -0.6 1. Position the drum shoe so that the current sensing plate faces down vertically. NOTE: Measure both the transfer and separation currents with the shoe at the same posi- tion.
Page 124
Turn off the main switch and then turn off DIP SW #2 on the switching board. Turn on DIP SW #1 on the switching board. Turn on the main switch and adjust the separation corona DC current by turning “VR.DC” on the T/S power pack. Turn off the main switch and then select the AC µA range of the digital multimeter.
6H-3. Belt Tension Adjustment Press the timing belt with a tension gauge as shown in the figure and adjust the tension by repositioning the tension pulley bracket. * Adjustment Standard: Development unit Drive Belt; Scanner Drive Belt; [FT3020] [FT3020] 6-77...
6H-4. Tension Spring Position The tension springs must be positioned differently depending on the local AC cycle frequency. Make sure that the tension springs are hooked to the proper position as shown in the figure. 6-79...
Page 131
July 1, ’85 Adjustment Item Adjustment Standard Note +4 ± 0.2V Image Density Sensor [FT3050/FT3060] Digital Multimeter Toner Supply Solenoid Stroke : 2 ± 0.5 mm (0.08” ± 0.02”) Toner Supply Sol 7 - 2...
Page 132
Adjustment Item Adjustment Standard Note Paper Lift Detector Clearance between pick-up roller and paper ; 2 ± 1 mm (0.08” ± 0.04”) Paper End Detector Thickness of the stack of removed paper ; 3 ± 1 mm (0.12“ ± 0.04”)
Page 133
Adjustment Item Adjustment Standard Note Paper Feed Solenoid Registration Solenoid Gap : 1 ± 0.2mm (0.04” ± 0.008”)
Page 134
July 1, ‘85 Adjustment Item Adjustment Standard Note ± 0.5% Horizontal Magnification [FT3020] Wire Clamp First Scanner ± 0.5% (Full Size) Horizontal Magnification [FT3050/ FT3060]...
Page 135
July 1, ’85 N o . Adjustment Item Adjustment Standard Note Home Position Home Position Switch turns [FT3020] on when the scanner bracket is 24.5 mm (0.96”) from the outside of the left optical frame. Home Position Sensor Home Position 35.5 ±...
Page 136
Note Adjustment Item Adjustment Standard -2 ± 2 mm Leading Edge Registration [FT3020] (-0.08” ± 0.08”) -2 ± 2 mm Leading Edge Registration [FT3050] (-0.08” ± 0.08”)
Page 137
Note Adjustment Standard Adjustment Item 0 1 2 3 4 5 6 7 8 9 A B C D E F Dial Settings -2 ± 2 mm Leading Edge Leading Edge Registration [FT3060] (-0.08” ± 0.08”) Registration 1.0 mm/Step Optics P C B Level 2 of the gray scale Light Intensity should be just barely visable...
Page 139
Note Adjustment Standard Adjustment Item 0.17 Scanner Drive Belt (0.38 Tension 0.17 Drum Drive Belt Tension Pulley (0.38 7-10...
Page 140
7B. DIP SW Table Usage of DIP SW 101 (on the main PCB) DIP SW 101 Free Run Normal Operation Count Down Count Up l/D Sensor LED ON Normal Operation (Toner Supply Control) ON (Fixed Mode) OFF (Detect Mode) 10.5% 3.5%...
Page 141
NOTE: *Free Run (after warm up.) The following functions are by-passed in this mode. • Paper End Key Counter • Toner End Interrupt • Paper Feed Image Density Keys • Jam Check Copy Quantity Keys • Total Counter Usage of DIP SW 201 (on the optics PCB) [FT3050/FT3060] Normal Operation Scanner Free Run...
Page 142
July 1, ’85 IV. Fusing Temperature Selection SW (on the fusing control unit) H 1 9 0 ° C N 1 8 5 ° C L 1 8 0 ° C 7-13...
Page 143
July 1, ’85 7C. Service Call Conditions INDICATOR POSSIBLE CAUSE CHECK POINT 24V is applied to CN103-1A Main Board Failure Harness or Connector (24VDC) Failure 24V is not applied to CN103-1A (Close Door) Thermofuse Failure 24V is not applied to CN82-6 While Key Counter is set, CN79-1, Key Counter Failure Main Board Failure...
Page 144
Scanner Drive Clutch-Forward Failure Scanner does not move (FT3020) Scanner Drive Motor Failure (Exposure, Optics) (FT3050/FT3060) Optics Board Failure (FT3050/FT3060) Home Position SW Failure Registration SW Failure (FT3020/FT3050) Scanner moves abnormally Overrun SWs Failure (FT3050) 7 - 1 5...
Page 145
POSSIBLE CAUSE CHECK POINT Scanner Drive Clutch – Return Failure ((FT3020) Scanner moves abnormally Scanner Drive Clutch Slippage (FT3020) (Exposure, Optics) Scanner Load is too heavy When the lens is at the home Lens HP Sensor Failure (FT3050/FT3060) position, 0V is still applied to CN202-9.
Page 146
July 1, ’85 CHECK POINT POSSIBLE CAUSE INDICATOR E3 is displayed soon after turning on the Main SW. Fusing Lamp on signal is applied to Fusing Control Unit Failure CN103-7B more than 130 sec. Fusing Lamp open (Fusing Abnormal) Main Board Failure Abnormal signal is applied Exhaust Fan does not rotate RA1 and/or Safety SW Failure (Warm up)
Page 148
July 1, ’85 8. P.M. TABLE * : Replace o : Clean # : Lubricata ITEM 80K 120K 160K 200K 240K NOTE OPTICS 1. Mirrors, Lens, Reflectors, Alcohol or Water (Si. Cloth) Sensor Pattern 2. Exposure Glass, Glass Cleaner and Dry Cloth Toner Shield Glass 3.
Page 149
Oct. 1, ’83 ITEM 80K 120K 160K 200K 240K NOTE CLEANING UNIT Clean with Blower Brush 22. Cleaning Blade Prime with Setting Powder 23. Cleaning Brush Prime with Setting Powder 24. Cleaning Unit 25. Pick-off Pawls Replace if Necessary FUSING UNIT 26.
Page 150
• Empty the used toner from the toner collection bottle into a vinyl bag at every service call. NOTE: • At every EM, check and adjust the exposure light intensity. • Check silicone oil level and add if necessary at every EM. •...
Page 154
TROUBLESHOOTING This compilation is intended to help the field service engineer solve some of the more common field prob- it does not cover all potential problems, and it in no way replaces good field troubleshooting lems. However, technique. Good field procedure and adequate machine knowledge must be developed and maintained by the service depot and the individual service engineer.
PHENOMENON ACTION Dirty background Clean the optics, toner shield glass, and quenching lamp filter. Check the pressure and release mechanism of the cleaning blade. Check that cleaning brush turns correctly. Clean the cleaning unit, and dust the cleaning blade, cleaning brush, and clean- ing side seals with setting powder.
Page 159
PHENOMENON ACTION Dirty background 6. Replace the cleaning blade assembly and/or the cleaning brush if necessary. CAUTION: Do not forget to dust them with setting powder. 7. Check the exposure lamp position. (See page 6-5.) 8. Adjust the lamp regulator output. (See page 6-65.) 9.
PHENOMENON ACTION Heavy background (No 1. Clean the optics and toner shield glass. image or very light 2. Check and adjust the exposure lamp position. (See page 6-5.) image) 3. Check for paper wrapped around the drum. 4. Open the platen cover and press the Print Key. Observe the intensity of the Do not look directly at the lamp.) If exposure lamp.
July 1, ’85 PHENOMENON ACTION White copy A totaly white copy may be the result of charge failure. 1. Check the charge corona unit contact. 2. Check the charge corona wire. 3. Check charge power pack input/output. 4. For the FT3050 and the FT3060, check the inner fuse of the main transformer. 5.
Page 162
PHENOMENON ACTION If it is gray rather than black, insufficient Check the color of the developer. toner is being supplied. Clean the ID sensor. Check toner supply clutch operation. Check toner end detector operation. Check the setting of DIP 101 switches 3, 4, and 5. (See page 7-11.) Check development bias.
PHENOMENON ACTION Uneven image density 1. Clean the optics. (side to side) 2. If that does not work, adjust the exposure lamp position. (See page 6-5.) 3. Try to correct the image using the exposure adjusting plates. (See page 6-6.) 4.
ACTION PHENOMENON Black stripe or band of Clean the toner shield glass and the quenching lamp filter. heavy background. Check for toner pile-up on top of the development unit. This may result from overtoning due to dirty ID sensor or ID sensor out of adjustment.
PHENOMENON ACTION Sharp vertical black lines. 1. Check the drum for scratches. 2. If the drum is scratched, determine and correct the cause before installing a new drum. Possible causes: • Warped cleaning entrance mylar seal. • Something caught in the development unit seals. •...
PHENOMENON ACTION Wavy black lines or Copy problems caused by the cleaning blade are often wavy. stripes. 1. Clean the cleaning unit; after that dust the cleaning brush and cleaning blade with setting powder. (See page 6-22.) 2. If the problem does not clear up, replace the cleaning blade (and brush). NOTE: If the cleaning blade edge is damaged, try to determine and correct the cause.
PHENOMENON ACTION Vertical white lines. Clean the charge corona wire; first with the wire cleaner, and if that does not work, with alcohol. Check the charge corona unit for hanging thread or fiber that may discharge the drum. Clean the development unit seals. 10-10...
PHENOMENON ACTION Black lines 251 mm 1. Check the drum. It must be either scratched or have a line of toner stuck on it. (9.88”) apart 2. Replace the drum if it is scratched. NOTE: Drum scratches often occur when the slide unit is reset without the drum The Mylar strip on the corona unit strikes the drum.
Dust the cleaning blade and brush. with setting (9.84”) from the leading powder. edge. Replace the cleaning blade and cleaning brush if they are too worn. (See page 6-22.) Check the positions of the original scale [FT3020] and the exposure glass [FT3050/FT3060]. [FT3020] [FT3050/FT3060] 10-12...
Page 170
ACTION PHENOMENON A small amount of oil marking, especially on the first copy, cannot be helped. But Oil marks at stripper do the following if excessive. Clean or replace the hot roller strippers. (See page 6-53.) Check that the contact edges (ends) of the pressure roller strippers are smooth and clean.
PHENOMENON ACTION Oil marks at stripper 8. If the above steps fail, replace and carefully position the oil supply pad and oil pawl positions. blade. (See pages 6-48 and 6-49.) 9. Replace the cleaning pad if it is too oily. (See page 6-47.) 10-14...
ACTION PHENOMENON 1. Check the fit of the cleaning blade bushing and cleaning blade holder. Poor cleaning on one side or the other. Sensor pattern appears on white copies. If they are not fitted together properly, the cleaning blade will not swivel and therefore will not set correctly against the drum when pressure is applied.
PHENOMENON ACTION The entire copy is 1. Set the charge corona unit correctly. covered with spots. This problem occurs when the spring in the endblock is not making good contact with the high voltage terminal. The image appears “sandy” or “speckled.” 10-16...
Page 174
PHENOMENON ACTION Leading edge dirty Adjust the position of the scanner home position sensor. (Move it to the right as viewed from the rear. See page 6-63 or 6-66-a.) background when copying colored originals CAUTION: Make sure that the scanner does not rebound when it returns to the and ID position is 5, 6, or home position.
July 1, ’85 PHENOMENON ACTION Jitter Adjust scanner drive belt tension. [FT3020] Adjust drum drive belt tension. [FT3050/FT3060] Adjust the development drive belt tension. Check the wire pulleys for wobble. Make sure the scanner drive wire moves smoothly. Clean the development unit gears.
PHENOMENON ACTION Light spots in solids 1. Clean the transfer and separation corona wires with alcohol and a clean cloth. (Usually elongate 2. If the problem persists, replace the wires. horizontally). NOTE: This problem may be caused by paper dust or clay on the wires. 1 0 - 2 0...
ACTION PHENOMENON Blurred or fuzzy image in Clean the drum with RICOH DRUM CLEANING POWER as follows. the center of copies. Materials needed: 1. Ricoh Drum Cleaning Powder (Part No. 5447 9605). 2. Isopropyl Alcohol. 3. Cotton Pads. 4. Plastic Bag for Waste Cotton.
Page 179
PHENOMENON ACTION Blurred or fuzzy image in 4. Mix the powder and alcohol until they form a thin paste. the center of copies. 5. Gently clean the drum stroking it smoothly from one end to the other, turning the drum slightly at the end of each stroke. CAUTION: (1) Do not rub the drum back and forth nor in a circular motion.
Page 180
PHENOMENON ACTION Blurred or fuzzy image in 10. Reinstall the drum and make 10 B4 copies. (To pick-up any excess cleaning the center of copies. powder). Then, operate the copier in free run mode for 2 or 3 minutes. (To help the drum recover its photoconductive characteristics).
PHENOMENON ACTION Paper feed jam Clean the pick-up, separation, and feed rollers. Clean and grease the slip clutch. Check the operation of the feed clutch, feed solenoid, and feed clutch pawl. Adjust and grease as necessary. Check the clearance between the pick-up roller and paper. Adjust the paper lift detector as necessary.
PHENOMENON ACTION By-pass feed jam Generally, jams occur in by-pass mode only when the cassette release mechanism is faulty. Check and adjust the operation of the cassette release link. Check and adjust the cassette lift mechanism. (The mechanism might be locked up.) Check the FRR rollers.
PHENOMENON ACTION Registration jam 1. Check the release and detent action of the registration clutch pawl. Adjust as necessary. 2. Clean and grease the registration clutch. 10-26...
Page 184
ACTION PHENOMENON Clean the separation corona wire and set the T/S corona unit correctly. Pick-off jam Adjust the transfer/separation corona currents. +0.06 µA • Transfer Corona ; DC + 14.6 -0.47 • Separation Corona ; AC 25.1 ± 1.5 µA DC -0.6 +0.25 µA -0.6 Check pick-off pawl operation.
PHENOMENON ACTION Fusing jam 1. Check the oil bottle and oil pump operation. Make sure the pump works pro- perly and that the oil tube extends to the bottom of the bottle. 2. Open the exit assembly and turn the fusing knob. Check whether oil is applied evenly to the hot roller.
PHENOMENON ACTION Fusing jam 5. If the oil pad is wet, make sure that the oil blade is set correctly as shown below. 1. Change the toner supply control DIP switches to a lower percentage combina- Toner falling from the tion: development unit.
PHENOMENON ACTION Toner falling from the 1. Clean the cleaning unit. cleaning unit. 2. Replace the first seal and/or side seals. NOTES: (1) When adhearing the first seal, make sure it is flat and not wavy. (2) When installing side seals, make sure they are aligned correct- ly.
Page 189
PHENOMENON ACTION E3 comes on 130 1. Check the AC line when the machine is at full power. 2. If AC power is 90% or less of the correct value, you must find a way to increase seconds after the main switch is turned on.
PHENOMENON ACTION Abnormal operation This may be caused by a short in the operation panel harness. panel display followed by Cover the exposed part of the harness with electrical tape. Replace the har- abnormal machine ness if it is badly damaged. operation.
Page 191
July 1, ’85 SECTION 11 FT3020/FT3050/FT3060 ELECTRICAL DATA...
Page 192
11D. FT3020/FT3050/FT3060 Schematic Main Board ........
Page 193
July 1, ’85 11A. FT3020/FT3050/FT3060 Connector List O … Used … Not used AC Harnesses 1 1 5 V 2 2 0 / 2 4 0 V CN NO. Description 3060 Lamp Regulator (CN1) Anticondensation SW Outlet Cooling Fan Motor...
Page 194
July 1, ’85 … Used … Not used 1 1 5 V 2 2 0 / 2 4 0 V CN NO. Description 3020 3 0 5 0 3 0 6 0 3 0 2 0 3050 3060 AC Interharness 3 Main Board (10, 29 VAC) Slide Unit Harnesses (AC and DC) 1 1 5 V...
Page 195
July 1, ’85 … Used … Not used DC Harnesses 1 1 5 V 2 2 0 / 2 4 0 V CN NO. Description 3020 DC Interharness CN 20 Slide Unit Power Pack-Charge, Bias (DC) Cleaning Solenoid Relays Main Board Main Board Main Board (to Operation Panel) Operation Panel Board...
Page 196
July 1, ’85 … Used … Not used 1 1 5 V 2 2 0 / 2 4 0 V CN NO. Description 3020 3050 3060 3 0 2 0 3050 3060 Registration Solenoid Paper Feed Sensor Add Toner Solenoid Pulse Generator Erase Lamps Quenching Lamps...
Page 197
July 1, ’85 … Used … Not used 1 1 5 V 2 2 0 / 2 4 0 V CN NO. Description 3020 3 0 5 0 3060 3020 3050 3060 Lens Drive Motor Overun SW (Enlarge) Not Used Paper Size Detection (By-pass) Lens Home Position SW Optics Board Harnesses...
Page 198
July 1, ’85 … Used … Not used Color 1 1 5 V 2 2 0 / 2 4 0 V Description Code 3020 3050 3060 3020 3050 3060 Neutral Anticondensation Heater Main SW Neutral Fuse 8A Circuit Breaker C(R) Fuse 3A C(R) RA2-1 (AC)
Page 199
July 1, ’85 … Used … Not used 1 1 5 V 2 2 0 / 2 4 0 V Color Description 3050 3060 3020 3050 3060 Code 3020 Noise Filter Safety SW Main Motor Capacitor Front Door SW Jam Reset SW Rear Cover Safety RA1 (DC) 11-7...
Page 200
July 1, ’85 O … Used x … Not used Color 1 1 5 V 2 2 0 / 2 4 0 V Description Code 3 0 2 0 3050 3060 3 0 2 0 3050 3060 RA2 (DC) Fusing Lamp Thermofuse 169 C Surge Suppression Capacitor Fusing Control Unit...
Page 201
July 1, ’85 11E. FT3050/FT3060 COMPONENT LAYOUT Electrical Component Layout OTHERS Anticondensation SW PCB’S Oil End Sensor Fusing Lamp 13 Lamp Regulator Board ([FT3050] machine serial Quenching Lamps 15 Operation Panel Board n u m b e r s o v e r 6 2 4 0 3 2 2 8 3 6 . ) 1 8 Erase Lamps 20 ID Sensor Board ([FT3060] for all serial numbers.) 61...