Download Print this page

GE C2S995SEL Training Bulletin page 3

Front control

Advertisement

7. Press '3' again and, if still no operation, check for line voltage between the low speed
(black wire) and neutral tabs. Also check for line voltage at the ERC between J903 pin 1
and neutral. If line voltage is not present, DISCONNECT POWER and replace the
MACHINE BOARD WITH FRAME.
Full Model Number
C2S995SEL1SS
PGS960BEL1TS, PGS960EEL1ES
PGS960FEL1DS, PGS960SEL1SS
CGS995EEL1DS, CGS995SEL1SS
CHS995SEL1SS
8. If line voltage is present, the BLOWER TANGENTIAL – WB26X29060 will have to be
replaced. Normally, the green sensor circuit board attached to blower motor will be good
and can be reused.
9. DISCONNECT POWER. Loosen the upper rear splash guard. Remove the three Hex-
head screws circled below to loosen side panel.
10. Disconnect three leads from motor and unplug six-pin connector. With a ¼" ratcheting box-
end or open-end wrench (arrow), remove the four hex-head screws that secure the blower
assembly to the duct. Carefully work blower assembly out of the duct.
Part Number of Machine Board
3
WB27X29494
WB27X29499
WB27X29499
WB27X29500
WB27X29501
continued...