Inputs/Outputs

On the back, the 8190S has an relay input, relay output, 24V output, and a Door Control
relay.
Terminal Block Relay In
By default, these terminals are inactive. Connection options are a normally closed switch,
normally open switch, 1202 Call Button, 1203 Call Switch, or EOL resistor termination.
These input switches can be used to trigger a call or audio announcement from the
device.
Terminal Block Relay Out
By default these terminals provide a contact closure when the 8190S SIP Classroom
Speaker is active.
Door Control
The door control provides both normally open (NO), common (C), and normally closed
(NC) relay contacts.
Document 90-00105
03/09/2020
Page 11
These contacts are not currently implemented in the
firmware, but will allow for future expansion.
Contact Algo for more information.