Wall Mounting; Programming And Configuration - Algo 8190S User Manual

Sip classroom speaker with strobe
Table of Contents

Advertisement

Wall Mounting

Mount the wall bracket securely. Once the wall bracket is secure, slides the 8190S onto
the bracket. Secure the 8190S to the wall bracket with the provided four screws.

Programming and Configuration

After connecting the 8190S to a network PoE+, the blue indicator light at the top will turn
on during initialization. The 8190S will then attempt to obtain an IP address from the
DHCP server. If there is no DHCP server or the attempt was unsuccessful, the 8190S will
default to the static IP address 192.168.1.111.
Note: If you don't have a PoE+ switch, you'll need a PoE+ injector installed between
the 8190S and the network switch. The PoE+ injector will supply 48 Vdc to the
8190S. Ensure that the injector is fully compliant to the IEEE 802.3at PoE+.
After a successful boot up the blue LED will turn off and you will hear a tone, and the
speaker will have obtained an IP address.
Press the reset button button (RST) momentarily to hear the IP address over the speaker
and press it again to stop playing the IP address over the speaker.
The IP address may also be discovered by downloading the Algo locator tool to find Algo
devices on your network:
Enter the IP address (e.g. 192.168.1.111) into a browser such as Google Chrome or Firefox. The
web interface should be visible and the default password will be algo in lower case letters.
Document 90-00105
03/09/2020
Page 10
www.algosolutions.com/locator
Algo Communication Products Ltd
4500 Beedie St Burnaby BC Canada V5J 5L2
www.algosolutions.com
8190S SIP Classroom Speaker with Strobe FW 3.1
support@algosolutions.com
(604) 454-3792

Advertisement

Table of Contents
loading

Table of Contents