FUEL AND OIL PRIMING
OIL SUPPLY PRIMING
15 – 90 HP Models
Use Evinrude Diagnostics software to m ake sure
the EMM is pro grammed for the type of oil being
used.
Start the outboard. Use th e oil priming function in
the sof tware to mak e sure the s ystem i s co m-
pletely primed.
Use the Prime Oil S ystem button of the Dynamic
Test screen to prime the oil pump.
1
Dynamic Test Screen
1. Prime Oil System button
If the "LOW OIL" warnin g was previously tested
(see LOW OIL Warning Test on p. 77), the warn-
ing should turn OFF during oil system priming.
Observe oil flow through all oil distribution hoses.
Air must be purged during the priming procedure.
1
40 – 90 HP Models
1. Oil distribution hoses
82
1
15 – 30 HP Models
1. Oil distribution hoses
Small bubbles are accept
must be eliminated through continued priming.
1
008570A
1. Oil distribution hose
2. Small bubbles
3. Large bubbles
Repair any fuel or oil leaks.
The oiling system on the se mod els can also be
primed using the Self-Winterizing featu re if diag-
nostics software is not available. Refer to Opera-
tor's Guide.
007997
able. Large bubbles
3
2
1
007130
004398