4.6 Configuration and Calibration Command List
Following is a list of commands which will operate in this Calibration mode.
Top Level Menu
ADJ <enter> Enter adjustment mode.
Q
Sub-Menu
NOTES:
1.
Backspace does not function. If a typing error occurs hit <enter> and begin again.
2.
A maximum error of ±499 feet may be introduced at any one altitude.
3.
CLR clears all error data in the EEPROM.
Quit command. Returns to normal operation.
CLR <enter>
D <enter>
P<enter>
Pabc<enter>
Q
Saa<enter>
Clear command clears error table data.
Dump to list all error table data.
Port status command, displays the current
port status. See § 4.4.
Port command, sets the serial port
resolution and protocol. See §4.4.
Quit command. Returns to top level menu.
Save to error table, 1000 foot altitude
(aa) mark at current input pressure.
20