Static Information - BRP Evinrude E-TEC Series Service Manual

Hide thumbs Also See for Evinrude E-TEC Series:
Table of Contents

Advertisement

R
S
M
OPE
TART
ODELS
Diagnostic communications on non-running rope
start models requires that power is supplied to the
EMM.
Use Diagnostic Power Supply Tool, P/N 587005,
to supply power to the EMM. The power supply
uses internal 9-volt batteries.
Connect Power Supply Tool to the engine harness
key/stop switch connector. Turn toggle switch to
the ON position to power the EMM.
1
1. Engine harness key switch connector
2. Power supply tool
IMPORTANT:
Static tests require more power
than the internal batteries of the tool can provide.
Static tests performed using only the internal
power supply batteries will produce false results.
Use Accessory Power Cable Kit, P/N 5008092, to
connect an external 12 volt battery to the Power
Supply Tool when performing these static tests:
Fuel pump
Fuel injector
Ignition coil
Oil injector
Accessory power cables
ENGINE MANAGEMENT MODULE (EMM)
DIAGNOSTIC SOFTWARE FUNCTIONS

Static Information

Static information is viewed when the outboard is
NOT running. This includes manufacturing infor-
mation.
The outboard model and serial numbers displayed
on the Identity screen must match the identifica-
tion label on the outboard swivel bracket.
2
Identity Screen
007385
The serial number and cylinder location displayed
on the Injector Coefficients screen must match the
actual cylinder placement for each injector.
Injector Coefficients Screen
007386
4
008136
008137
59