Disconnect vapor separator and fuel injector elec-
trical connectors. Remove connectors from retain-
ers.
1
1. Electrical connectors
Remove clamps and fuel supply hose, vapor sep-
arator vent hose and cooling water hoses.
Loosen four injector screws.
Remove three vapor separator retaining screws.
Remove vapor separator.
1
1. Retaining screws
FUEL COMPONENT SERVICING
Fuel Injector Removal
Mark fuel injectors to show cylinder locations.
NOTICE
Fuel injectors must be installed in
the correct cylinder locations. Use Evinrude
Diagnostics Software to make sure that EMM
programming matches injector positioning.
The Injector Coefficients screen displays
1
injector serial numbers for each cylinder.
007423
Injector Coefficients Screen
Use caution when handling fuel injectors. Prevent
dirt and debris from entering fuel inlet and outlet
ports of injectors. Cover the injector nozzle port in
cylinder head to prevent contamination of com-
bustion chamber.
007285
Remove injector screws.
1. Injector screws
Remove fuel injector and insulator.
007098
FUEL SYSTEM
7
008137
1
007100