Method 2
Disconnect all cables and lead wires from the
starter motor relay. Measure the continuity
between the relay terminals.
Connect the yellow/green wire to the positive (+)
battery terminal and the black wire to the negative
(–) battery terminal. Connect the test probe
between the relay terminals. Then disconnect the
wiring leads from the battery.
1
2
Y/G
Starter Motor Relay Terminal Continuity Test
Test probe
connection
Red (+)
Black (–)
Terminal 1 Terminal 2
If the measurements are out of specification,
replace the starter motor relay.
B
001704
Result
12V applied: Continuity
No voltage: No continu-
ity
STARTER MOTOR
Removal
Disconnect the battery cables at the battery.
Remove three (3) bolts and the flywheel cover.
1
1. Bolts (3)
2. Flywheel cover
Remove the bolt and the negative battery cable.
1
2
1. Bolt
2. Negative battery cable
ELECTRICAL
STARTER MOTOR
2
001394
001705
91