ELECTRIC STARTER SYSTEM

Test Procedures

Checking the Starter Switch for Continuity
(TEL Models only)
Disconnect the starter switch lead wire. Check for
continuity between the wiring leads under the fol-
lowing conditions.
Starter Switch Continuity Test
Tester probe
connection
Red (+)
Black (–)
White/Red
Brown
1. Depressed
2. Not depressed
Checking the Neutral Switch for Continuity
(TEL Models only)
Disconnect the neutral switch lead wires. Check
for continuity between the yellow/green and brown
lead wires while operating the shift lever or remote
control handle.
1
2
3
1. FORWARD position
2. NEUTRAL position
3. REVERSE position
90
Result
Not depressed: Infinity
Depressed: Continuity
W/R
1
2
Br
001701
Y/G
Br
001702
Neutral Switch Continuity Test
Shift Position
Neutral
Forward
Reverse
If the results are out of specification, first check
the switch position. Adjust if necessary.
If the results are still out of specification, replace
the neutral switch. After installing a new neutral
switch, check for correct function by operating the
remote control handle or the shift lever.
Checking the Starter Motor Relay
Two methods can be used to test the starter motor
relay.
Method 1
Disconnect all cables and lead wires from the
starter motor relay. Measure the resistance
between the relay wiring leads.
Starter Motor Relay Resistance Test
Tester probe
connection
Red (+)
Black (–)
Yel-
Black
low/Green
If the measurement is out of specification, replace
the starter motor relay.
Result
Continuity
Infinity
Infinity
B
Y/G
Resistance
3.5 - 5.1 ohms
001703