Test Procedures - BRP Johnson J30TEL4SUA 2007 Service Manual

30 hp, 4 stroke
Table of Contents

Advertisement

If the engine speed is over 3000 RPM, the over-
revolution caution control will be activated. The
engine speed will be automatically controlled by
ignition interruption and lowered to approximately
3000 RPM.
To cancel the overheat caution control, the cylin-
der wall temperature must be reduced to less than
158°F (70°C) and, at the same time, the engine
speed must be decreased to 1500 RPM or lower.

Test Procedures

Checking the Oil Pressure Switch
IMPORTANT:
Before checking the low oil pres-
sure caution circuit, make sure the engine oil
pressure is over 7 psi (49 kPa).
Remove the blue/yellow lead wire from the oil
pressure switch. Check for continuity between the
switch terminal and the engine body ground.
If the measurement is out of specification, replace
the oil pressure switch.
Low Oil Pressure Caution Circuit Test
Engine running
Engine stopped
1
1. Oil pressure switch
Checking the Caution Lamp
Remove the blue/yellow lead wire from the oil
pressure switch. Start the engine.
Touch the blue/yellow lead wire to the engine
body ground. If the caution lamp comes on, the oil
pressure switch circuit and the caution lamp circuit
are functioning normally.
If the caution lamp does not come on, disconnect
the caution lamp lead wires from the engine har-
ness.
Connect 2 pin test cord, P/N 5034617, then con-
nect the caution lamp lead wires to a 1.5V battery.
If the caution lamp does not come on, replace the
lamp.
Infinity
Continuity
1. 1.5V battery
2. 2 pin test cord
001670
Caution Lamp Test
Battery connection
Positive (+)
Negative (–)
Pink
Black
Black
ENGINE CONTROL
CAUTION SYSTEMS
Result
Lamp ON
2
Pink
1
001671
79
4

Advertisement

Table of Contents
loading

This manual is also suitable for:

Johnson j30pl4sua 2007

Table of Contents