Emergency Stop Switch; Ignition Coil - BRP Johnson J30TEL4SUA 2007 Service Manual

30 hp, 4 stroke
Table of Contents

Advertisement

Emergency Stop Switch

The emergency stop switch is connected to the
power pack through the engine wiring harness.
When activated, this switch directs the power
pack output to ground, stopping the ignition sys-
tem.
1. Emergency stop switch
When the clip and lanyard assembly is removed,
the emergency stop switch is in the STOP posi-
tion.
When the clip and lanyard assembly is installed,
the emergency stop device is in the RUN position.

Ignition Coil

The ignition coil consists of two windings of wire
wrapped around a compacted ferrite core. The
coil has primary and secondary terminal connec-
tions and a ground plate.
Through mutual induction, the ignition coil trans-
forms the ignition module output to as much as
40,000 V to fire the spark plugs. There is one igni-
tion coil per cylinder.
1
001656
1. Ignition coil No. 1
2. Ignition coil No. 2
3. Ignition coil No. 3
ENGINE CONTROL
COMPONENTS
1
2
3
001652
71
4