Water Pressure Connection - BRP Evinrude E-TEC G2 150 HP Installation & Predelivery Manual

Table of Contents

Advertisement

Outboard Rigging
Buss Cable, Hoses, and Wire Routing and Connections
4. From the Device List select Disconnect Device.
1. Device List
2. From the Device List select the EMM for the
next engine.
3. Repeat steps 3, 4 and 6 through 9 for each
engine.
4. After engine identity has been set for each
engine, turn the key switch OFF and back ON
to complete the procedure.

Water Pressure Connection

To send water pressure data to the EMM, along
with an NMEA 2000 display, install 50 psi Water
Pressure Transducer Kit, P/N 5008640.
Water pressure readings in excess of 40 psi (275
kPa) are possible at boat speeds in excess of
50 mph (80 kph/43 kts).
IMPORTANT:
Use the fittings and hose supplied
with the kit. Do NOT install the transducer directly
into the block.
66° V6 Models
Install the water pressure transducer to the acces-
sory water pressure hose located beneath the fuel
74
1
009161
filter. Refer to the installation instructions provided
with the water pressure transducer kit.
1. Accessory water pressure hose
74° V6 Models
Remove the accessory water pressure plug from
the engine to install the water pressure trans-
ducer. The plug is located behind the oil supply
hoses. Refer to the installation instructions pro-
vided with the water pressure transducer kit.
1. Accessory water pressure plug
1
009891
1
009119

Advertisement

Table of Contents
loading