Remote Controls; Icon Ii Remote Controls; Remote Control Installation - BRP Evinrude E-TEC G2 150 HP Installation & Predelivery Manual

Table of Contents

Advertisement

Boat Rigging

Remote Controls

Remote Controls
WARNING
Remote controls must have start-in-gear pre-
vention. This feature can prevent injuries
resulting from unexpected boat movement
when the outboard starts.
Always install and recommend use of an
engine cut-off switch. Doing so will reduce
the risk of personal injury or death should the
operator fall away from the controls or out of
the boat.
Refer to Remote Control System Selection on
p. 16. An online Rigging Configurator is also avail-
able on BOSSWeb.

ICON II Remote Controls

Beginning with AFA model 200 H.O. – 300 HP, 74°
V6 engines, the engine management software
and ICON II remote control firmware has been
updated to support Evinrude i-Dock steering.
Remote Control Firmware
Remote controls MUST have the firmware listed in
the table below to function properly with the
engines listed. Incorrect firmware will result in a no
crank, no start situation.
ICON II
Remote
AAA &
Control
Newer
Type
66° V6
SW0252
Concealed
RevE or
Side Mount
higher
Single
SW0252
Lever
RevE or
Binnacle
higher
Mount
Dual Lever
SW0253
Binnacle
RevD or
Mount
higher
If installation of a new engine and remote control
results in a no crank, no start situation, use Evin-
rude Diagnostics software v 6.1 or higher to deter-
mine the remote control firmware.
28
Firmware
AFA &
ABA
Newer
74° V6
74° V6
SW0252
SW0252
RevE or
Rev20A
higher
SW0252
SW0252
RevE or
Rev20A
higher
SW0253
SW0253
RevD or
Rev16A
higher
Refer to the installation instructions provided with
the remote control to update the remote control
firmware.
Remote Control Applications
ICON II remote controls are designed for the fol-
lowing applications:
Concealed side mount – Single outboard, single
station applications only.
Foot throttle (optional) – Accessory for use with
the concealed side mount control only. NOT for
use with binnacle mount remote controls.
Single lever binnacle mount – Single outboard,
single or dual station applications.
Dual lever binnacle mount – Two, three or four
outboard, single or dual station applications.

Remote Control Installation

Plan the installation of remote controls carefully,
following all instructions provided with the control.
Select an appropriate location based on the boat
configuration.
1
1. Side console
2. Center console
IMPORTANT:
The mounting location must be a
flat surface and must be strong enough to provide
rigid support. Strengthen mounting surface as nec-
essary.
Place remote control at proposed location and
check clearance around remote control lever at
full throttle in FORWARD and then at full throttle in
REVERSE. There must be at least 2.5 in. (64 mm)
2
009134

Advertisement

Table of Contents
loading

Table of Contents