1.2.2 Installing firmware

Note:
• DO NOT disconnect the AC cord or USB cable from the machine or computer during
installing.
• If the install is failed, turn OFF the machine and turn it back on. The machine enters
the firmware installing mode automatically. Continue to the operating procedure below
from the procedure (2).
<Operating Procedure>
(1) If the computer is connected to the machine using the USB cable, disconnect the USB cable to
enter maintenance mode. (Refer to
the supply PCB is replaced with a new one, the machine automatically enters maintenance
mode by turning it ON so the procedure below to enter the maintenance mode is not necessary.
(2) Connect the machine to your computer using the USB cable.
(3) Open the temporary folder and double-click "FILEDG32.EXE" to start it, and select
"Maintenance USB Printer".
(4) Drag and drop the required program file (ex: LZXXXX_$.djf) in the same folder onto the
Maintenance USB Printer icon. The file is loaded to the machine, and installing to the
flash ROM starts.
(5) When installing is completed, the machine restarts and returns to the ready state automatically.
(6) Turn OFF the power switch of the machine, and then repeat the procedures (1) to (5) to
install required firmwares. However, when the supply PCB is replaced with a new one,
the machine automatically enters maintenance mode by turning it ON so the procedure
(1) to enter the maintenance mode is not necessary.
(7) Turn OFF the power switch of the machine, and disconnect the USB cable.
1.3 Initializing the EEPROM of the Main PCB ASSY
(Function code 01)
Initialize the EEPROM of the main PCB ASSY as described in
parameters (Function code 01, 91)" in Chapter

1.4 Acquiring White Level Data (Function code 55)

Acquire white level data as described in
area (Function code 55)" in Chapter
"1.1 How to Enter Maintenance Mode" in Chapter
5..
"1.3.15 Acquire white level data and set CIS scan
5.
4-6
5) When
"1.3.1 Initialize EEPROM