  Connecting Communication to the Meter

Connecting Communication to the Meter

If a meter was installed, connect it to the StorEdge Connection Unit as described in the
following table. For detailed information refer to the installation guide supplied with
the meter.
Recommended cable type
(min-max AWG)
RS485 24 AWG (16-24
AWG), shielded twisted
pair, 600V insulated
Connect as illustrated below:
Figure 28: StorEdge Connection Unit DIP switches
StorEdge Connection
Unit
Ext. Devices 7-pin
terminal block: B, A, G
Meter connection
RS485 4-pin terminal block: B, A, G
StorEdge Solution with Backup MAN-01-00262-1.5