SolarEdge StorEdge Solution with Backup Installation Manual page 123

Table of Contents

Advertisement

122
  Verifying StorEdge Components Functionality
I m p o r t M e t e r
S t a t u s :       < O K / E r r o r # >
P o w e r [ W ] :         x x x x x . x
E n e r g y [ W h ] :       X X X X X . X
 4. Press the inverter LCD light button to display the Smart Energy Management and
the Battery status screens, and check that:
State = Discharging (assuming consumption > PV production ; inverter
maximum AC power > PV  production.
PWR > 0
B S N : X X X X X X X X I D : 2 4
S O E : 8 9 %           P W R : 2 W
T o t a l : < X > W h
S t a t e :   D i s c h a r g i n g
 5. While the PV modules are exposed to sunlight , verify that the battery is charging
properly:
 a. Minimize consumption by turning off all the load circuit breakers, except for the
inverter.
 b. In the inverter LCD check that the Meter status screen is displaying import power
close to zero.
 c. Press the external LCD light button to display the Battery status screen, and
check that:
State = Charging
SOE percentage is increasing
PWR > 0
B S N : X X X X X X X X I D : 2 4
S O E : 8 9 %           P W R : 2 W
T o t a l : < x > W h
S t a t e :   C h a r g i n g