* Learn spring type must be carried out without connection to the door leaf!
(Before initiating this function, the arms must be dismounted, i.e. the door leaf must not be con-
nected to the operator!).
If a control unit is exchanged, this function hast to be initiated!
** In order to definitively carry out this function, a Reset must be initiated within 9 seconds. This can
also take place on the DFA 127 via an EMERGENCY STOP, or a reset on a BDE-D.
If factory settings have been entered with the service and flash programmer FPC 902, the reset
must also be actuated by the FPC.
14.2

Electronic controller BDE-D (Option)

14.2.1

Adressing of the electronic controller

BDE 1 with Bus termination (rear face)
102-127108955
IMPORTANT
The following listed functions can only be checked after learning of running pa-
rameters or after learning of CAN-sensors.
At the same time the addressing of CAN-sensors will be checked.
Installation with 1 BDE-D
Operating instructions DFA 127
The BDE-D electronic controller is an easily oper-
ated input and output device for the control and
adjustment of door operators. Logically arranged
pushbuttons allow intuitive operation and naviga-
tion through the operator specific menu. The LCD
with backlight shows data and information about
the door status with symbols and text messages.
Additional information can be found in the BDE-D
manual (No. 102-903108983).
BDE 2 without Bus termination (rear face)
V1.1
Installation with 2 BDE-D
14
55/ 102