4.3

Generally authorised speed settings

The default values of low-energy operators for authorised speeds are shown in the EN
16005. They are calculated depending on door leaf weight and door width, in which the ki-
netic energy of a moving door should not exceed 1.6 J.
Time T corresponds to the minimum opening time (in seconds) until beginning of the open-
ing damping or until 80° C of door opening, or the minimum closing time (in seconds) from
90° C to 10° C of door opening (+ at least 1.5 s from 10° C to 0° C).
These times must be tested with appropriate measuring device (e.g. stop watch). The time
data is rounded on halve a second.
Width of door
leaf [mm]
750
850
1000
1200
1300
1400
102-127108955
50
60
70
3.0
3.0
3.0
3.0
3.0
3.5
3.5
3.5
4.0
4.0
4.5
4.5
4.5
4.5
5.0
4.5
5.0
5.5
NOTICE
For parameter settings please see also chapter description of parameters!
Technical Data DFA 127
Door leaf weight [kg]
80
90
100
110
Min. time T [s]
3.0
3.5
3.5
3.5
4.0
4.0
4.0
4.5
4.5
5.0
5.5
5.5
5.5
5.5
6.0
6.0
6.0
6.5
V1.1
120
130
140
3.5
4.0
4.0
4.0
4.0
4.5
4.5
4.5
5.0
5.0
5.5
5.5
6.0
6.0
6.5
6.5
4
150
160
4.5
4.5
5.0
5.0
5.5
6.0