Technical Data DFA 127

Dimensions:
Operating voltage:
Power consumption:
Max. torque:
Mass inertia:
Opening angle:
Time delay:
Opening speed:
Closing speed:
Noise emission:
Protection class:
Environment conditions
Temperature range:
Humidity range:
4.1

Door leaf weights and door widths

The curves are calculated using the following formula:
Standard arms:
Slide arms:
102-127108955
Operator 600 x 85 x 124 mm (wxhxd)
230VAC, 50/60 Hz
Standby 13 W, rated power 67 W
50 Nm
65 kgm
adjustable from 70° to 115°
adjustable from 0 to 60 seconds (40 steps)
adjustable from 3 to 20 seconds (40 steps)
adjustable from 5 to 20 seconds (40 steps)
< 45 dB
IP20
-15° C bis +50° C
up to 85% relative humidity, non condensing
J max. 65 kgm
2
J max. 65 kgm
2
V1.1
Technical Data DFA 127
2
J=1/3 x m x b
2
Key:
J = mass moment of inertia kgm
m = door leaf weight in kg
b = door leaf width in m
4
2
20/ 102