3.2.2

Additional requirements for doorsets in escape routes and emergency exits

When an operating mode selector is used, the mode of operation shall be clearly identified
and marked on the operating mode selector.
If a "locked" mode of operation is available, the mode of operation shall be protected, e.g. by
an access code or a key, so that changes can only be made by authorised personnel.
Solution:
The system 20 RED with additional control unit BDE-V (night locking device with key-
operated switch).
3.2.3

Marking of glass

Transparent leaves or leaf surfaces shall be clearly recognisable, e.g. by permanent mark-
ing, suitable labels or by using coloured materials.
Solution:
Affix adhesive strip or mark.
3.2.4

Guards

Protective measures such as enclosures, covers, enclosing guards or fixed protection leaves
shall be designed so that:
1. Persons cannot reach any danger point up to a height of 2,5 m above floor level;
2. They can only be removed or opened with the aid of a tool.
Solution:
This requirement can be met by using the option "lockable casing".
3.2.5

Commissioning and information for use

The operator shall be instructed during commissioning.
Moreover, he shall be provided with a user handbook including instructions for routine main-
tenance.
The recommended frequency for checking the correct operation of safety function and de-
vices is, at least, once a year and is to be carried out by professionals.
Furthermore, maintenance operations are required to be recorded in a log book, which is de-
livered to the operator.
Solution:
Inform the operator about the necessity of maintaining and checking the safety function and
emphasise the advantages of having a maintenance contract.
Deliver a log book, or place it in the drive.