Immergas MAGIS PRO ERP Instruction And Recommendation Booklet page 27

Mono-phase hydronic module to pair with an outdoor condensing unit
Table of Contents

Advertisement

Integration menu.
Id
Parameter
Parameter
DHW integration
Allows you to enable an alternative power source (AL) to integrate domestic
I 01
enabling
hot water heating.
System integra-
Using this function, you can enable an alternative (AL) or simultaneous (CO)
I 02
tion enabling
power source to integrate heating system central heating.
DHW max wait
I 03
Establishes the maximum amount of time before activating DHW integration.
time
Central heating
Establishes the maximum amount of time before activating central heating
I 04
max wait time
integration.
Activation tem-
Establishes the outdoor temperature under which central heating integration
I 08
perature
is enabled.
Maintenance menu.
Accessing this menu, the unit goes into stand-
by. By selecting every single parameter, you can
activate a specific function for each load.
Id
Parameter
Parameter
In the case of new central heating systems and in particular mode for floor
systems, it is very important that dearation is performed correctly. The
function consists of the cyclic activation of the pump (100 s ON, 20 s OFF)
and the 3-way valve (120 s D.H.W., 120 s heating system).
M 01
Venting
The function lasts for 18 hours and can be interrupted by pressing the "ESC"
button and setting the function to "OFF"
Activation of the function is signalled by the countdown shown on the
indicator (14).
System circulator
M 02
Establishes the system circulator speed
speed
M 03
DHW 3-way
Moves the 3-way motor from system to DHW
M 04
Cooling 3-way
Moves the cooling circuit 3-way motor
Zone 1 outdoor
M 08
Enables the zone 1 outdoor circulator
circulator
Zone 2 outdoor
M 09
Enables the zone 2 outdoor circulator
circulator
M 10
Mixer zone 2
Establishes zone 2 mixing valve positioning
DHW electrical
M 11
Enables the DHW integrated electrical resistance
resistance
Central heating
M 12
electrical resist-
Enables the room central heating integrated electrical resistance
ance
Dehumidifier
M 13
Enables the dehumidifier in zone 1
zone 1
Dehumidifier
M 14
Enables the dehumidifier in zone 2
zone 2
M 15
Relay 1
Enables relay 1 on the 3-relay board
M 16
Relay 2
Enables relay 2 on the 3-relay board
M 17
Relay 3
Enables relay 3 on the 3-relay board
Description
Description
27
Customised
Range
Default
value
OFF - AL
OFF
OFF - AL
OFF
- CO
0 - 900
minutes
30
(10 minute
intervals)
0 - 900
minutes
45
(10 minute
intervals)
-15 ÷ 20 °C
-5
Customised
Range
Default
value
OFF - ON
OFF
0 - 100%
0
OFF - ON
OFF
OFF - ON
OFF
OFF - ON
OFF
OFF - ON
OFF
OFF
- OPEN -
OFF
CLOSE
OFF - ON
OFF
OFF - ON
OFF
OFF - ON
OFF
OFF - ON
OFF
OFF - ON
OFF
OFF - ON
OFF
OFF - ON
OFF