2.6 PARAMETERS AND INFORMATION
MENU.
Pressing the "MENU" button (2), the display
cyclically shows the "Data" menu, "User" menu
and a menu protected by a "0000" access code
with the first flashing digit reserved for a qualified
technician.
Data Menu.
Id
Parameter
D 03
Storage tank unit temperature
D 04
Value calculated for system setting
D 05
Value set for DHW setting
Outdoor temperature (if the condensing unit external probe is connected or if the optional external probe is availa-
D 06
ble)
D 08
System return water temperature
List of the last five anomalies.
D 09
(to scroll through the list, press the "OK" button (1))
Anomaly list reset. Once "D 10" is displayed, press the "OK" button. Deletion is confirmed via the "88" symbols
D 10
flashing for two seconds.
D 14
Circulator flow rate
D 20
System flow temperature
D 22
DHW 3-way (DHW = domestic hot water, CH = central heating)
D 24
Chiller circuit liquid temperature
D 25
Zone 2 flow temperature (if configured)
D 26
Probe for primary solar storage (puffer)
D 28
System circulator instantaneous speed
D 31
DHW integration function
D 32
System integration function
D 35
Solar system inlet
D 41
Zone 1 relative humidity
D 42
Zone 2 relative humidity
D 43
Zone 1 humidistat
D 44
Zone 2 humidistat
D 45
Dehumidifier zone 1
D 46
Dehumidifier zone 2
D 47
Zone 1 circulator pump
D 48
Zone 2 circulator pump
D 49
Central heating / cooling system separation 3-way (CL = cooling, HT = heating)
D 51
Zone 1 remote control
D 52
Zone 2 remote control
D 53
System setting with remote connection in zone 1
D 54
System setting with remote connection in zone 2
D 55
Zone 1 thermostat
D 56
Zone 2 thermostat
D 61
Appliance model definition
D 62
Communication with outdoor condensing unit
D 63
Communication with other Immergas devices
D 71
Condensing unit operating frequency
D 72
Condensing unit compressor temperature
D 73
Compressor outlet instantaneous temperature
D 74
Evaporator coil temperature
D 75
Condensing unit compressor absorption
D 76
Condensing unit fan speed
D 77
Electronic expansion valve position
D 78
4-way side (CL = cooling, HT = heating)
D 91
Software version
To access an individual menu, once it appears,
press the "OK" button (1).
To scroll through the menu items and to edit the
values, use the DHW temperature regulation but-
tons (4). Pressing the "OK" button (1) confirms
the parameter, pressing the "ESC" button (3) goes
Description
18
back to the previous menu or exits.
A minute after the last operation, the system
automatically exits any of the menus.
0 ÷ 99 °C
0 ÷ 99 °C
0 ÷ 99 °C
- 20 ÷ 50 °C
0 ÷ 99 °C
D91 ÷ D95
(x 100 l/h)
0 ÷ 99 °C
DHW - CH
- 20 ÷ 99 °C
0 ÷ 99 °C
0 ÷ 99 °C
0 ÷ 100 %
OFF - ON
OFF - ON
OFF - ON
OFF - ON
OFF - ON
OFF - ON
OFF - ON
OFF - ON
OFF - ON
OFF - ON
OFF - ON
0 ÷ 99 °C
0 ÷ 99 °C
OFF - ON
OFF - ON
OFF - ON
OFF - ON
0 ÷ 150 Hz
0 ÷ 200 °C
0 ÷ 100 °C
0 ÷ 100 °C
0 ÷ 100 rpm
Range
-
0 ÷ 9999
0 ÷ 99 %
0 ÷ 99 %
CL - HT
MP
0 ÷ 10 A
0 ÷ 500
HT / CL